background image

Table 50 Error Codes — Part Code 6005

(continued)

Failure
Level

Severity
Level

Recommended Action

Error Message

Error
Number

Part
Code

5

i

Check the licensed capacity
of Data Retention Utility on
the RCU side, or confirm
whether Data Retention Utility
is installed on the RCU. To
execute this operation,
purchase a license key that
allows you to use a larger
capacity or install Data
Retention Utility on the RCU.
When an SLPR is allocated,
check the licensed capacity
of the SLPR.

A pair cannot be created
because the licensed capacity
of Data Retention Utility on
the RCU side is insufficient or
Data Retention Utility is not
installed on the RCU.

58452

6005

6

E

Check the licensed capacity
of Data Retention Utility on
the MCU side or confirm
whether Data Retention Utility
is installed on the MCU. To
execute this operation,
purchase a license key that
allows you to use a larger
capacity or install Data
Retention Utility on the MCU.
When an SLPR is allocated,
check the licensed capacity
of the SLPR.

A pair cannot be created
because the licensed capacity
of Data Retention Utility on
the MCU side is insufficient
or Data Retention Utility is not
installed on the MCU.

58454

6005

5

i

Use another volume, or
recreate the XP Continuous
Access Journal pair or the
Universal Replicator for
Mainframe pair using a
mirror ID other than 0. Then
retry the operation.

The specified M-VOL is
already used as a primary
data volume for XP
Continuous Access Journal or
Universal Replicator for
Mainframe. To use the
M-VOL in conjunction with
one of these program
products, recreate the XP
Continuous Access Journal
pair or the Universal
Replicator for Mainframe pair
using a mirror ID other than
0, and retry the operation.

58460

6005

5

i

Specify another volume.

A pair cannot be created
because the specified M-VOL
is being used by XP
Snapshot.

58494

6005

5

i

Specify another volume.

A pair cannot be created
because the specified R-VOL
is being used by XP
Snapshot.

58495

6005

5

i

Specify another volume.

A pair cannot be created
because the specified M-VOL
is a virtual volume.

58496

6005

5

i

Specify another volume.

A pair cannot be created
because the specified R-VOL
is a virtual volume.

58497

6005

Remote Web Console Error Codes 245

Содержание XP20000/XP24000

Страница 1: ...s Abstract This document lists the error codes and error messages for HP StorageWorks Remote Web Console for HP StorageWorks XP disk arrays and provides recommended action for the error conditions HP Part Number AE131 96086 Published May 201 1 Edition Fourteenth ...

Страница 2: ... persons or entities listed on the U S Department of Commerce Denied Persons List Entity List of proliferation concern or on any U S Treasury Department Designated Nationals exclusion list or to parties directly or indirectly involved in the development or production of nuclear chemical biological weapons or in missile technology programs as specified in the U S Export Administration Regulations 1...

Страница 3: ...torage System Messages 4 Message Window Format 4 Remote Web Console Error Codes 5 2 Support and Other Resources 444 Related Documentation 444 Conventions for Storage Capacity Values 444 HP Technical Support 444 Subscription Service 444 HP Websites 445 Documentation Feedback 445 Glossary 446 Contents 3 ...

Страница 4: ...on the operating system and browser used GUI contents also vary with licensed program products storage system models and firmware versions Remote Web Console for Storage System Messages Figure 1 page 4 shows a typical message window displayed by Remote Web Console Figure 1 Sample Message Window Information Level Message Message Window Format Figure 2 page 4 illustrates the format of the message wi...

Страница 5: ...Console starts and displays the following message see the code and number the YYYY ZZZZZ represents A check box may be indicated in the message window If you check the check box the message will not be displayed until you log in again A network error occurred the server is not ready or an error occurred in the server YYYY ZZZZZ Remote Web Console Error Codes To find solutions to the Remote Web Con...

Страница 6: ... 1001 0001 2 E If this problem persists call HP technical support The specified volume cannot be set as a command device or a component of a LUSE volume because it is being used as a XP Continuous Access Business Copy or Flex Copy XP Select another volume 1002 0001 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP techni...

Страница 7: ...ts call HP technical support 4001 0001 2 E Input the correct user name and log in again An error occurred If this problem persists call HP technical support 4003 0001 2 E Input the correct password and log in again An error occurred If this problem persists call HP technical support 4004 0001 5 W Because the same user name is being used log in with another user name The user ID is already logged i...

Страница 8: ...rrect user ID or password The user ID or password is invalid 5014 0001 2 W If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5075 0001 2 E If the same problem persists despite retrying call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5099 0...

Страница 9: ...HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5515 0001 2 E If the same problem persists despite retrying call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5516 0001 2 E If the same problem persists despite retrying call HP technical support An error occurred during ...

Страница 10: ...istrator cannot be added or deleted Check the setting and then retry the operation 5554 0001 2 E The password flag is invalid Check the setting and then retry the operation The password flag is invalid Check the setting and then retry the operation 5555 0001 2 E The password is invalid Check the setting and then retry the operation The password is invalid Check the setting and then retry the opera...

Страница 11: ...support 5813 0001 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5814 0001 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6002 0001 2 E If this problem persists call HP technical support An error occurr...

Страница 12: ...The version of Remote Web Console may not match the version of the destination SVP Clear the cache of JRE and the browser Restart the browser and then retry the processing If this problem persists the proxy server may be the cause of the problem Contact your network administrator If your network is not having any problems and if this problem persists call HP technical support 7050 0001 2 E If the ...

Страница 13: ...he connection between the SVP and the FTP server 56551 0001 5 W Check the setting The file transfer to the FTP server failed Check the user ID and the password 56552 0001 5 W Check the output folder and the status of the FTP server The file transfer to the FTP server failed Check the output folder and the status of the FTP server 56553 0001 5 E If this problem persists call HP technical support Th...

Страница 14: ...can be registered because the number of registered P9000 or XP Command View Advanced Edition version information reached the maximum Reduce the number of P9000 or XP Command View Advanced Edition version information and then retry the operation 66802 0001 Table 2 Error Codes Part Code 0002 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 6 E The configuration in...

Страница 15: ...s problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 2010 0002 2 E Call HP technical support The server configuration is invalid Call HP technical support 201 1 0002 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 2012 ...

Страница 16: ...ion Wait a few seconds and then click Refresh on the File menu or Wait a few seconds and login again 5510 0002 6 E Delete paths and host groups separately You cannot delete paths and host groups at the same time 5513 0002 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6000 0002 2 E If this problem pe...

Страница 17: ...If this problem persists call HP technical support 7060 0002 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 71 1 1 0002 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 721 1 0002 2 E If this problem pers...

Страница 18: ...The Login could not be performed because a function failed to start during SVP initialization Call HP technical support 66100 0002 Table 3 Error Codes Part Code 0003 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again You are ...

Страница 19: ...mulation types of the volumes combined into a LUSE volume are not the same 1013 0003 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again LU path is set to the releasing expanded LU You need to release the expanded LU and path at the same time 1015 0003 2 E The specified port does not exist You have specified a...

Страница 20: ...ion The error does not occur normally because it is guarded in the screen In the unlikely event that this error occurs contact HP technical support An error occurred If this problem persists call HP technical support 1024 0003 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again The specified LU path does not e...

Страница 21: ...g SVP processing If this problem persists call HP technical support 1035 0003 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 1036 0003 2 E There is no capacity left in the logical parity group to create CV The error does not occur normally because it is guarded in the screen In the unlikely event tha...

Страница 22: ...all HP technical support 1046 0003 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 1048 0003 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists please call HP technical support 1049 0003 2 E If this problem persists call HP technical...

Страница 23: ...iguration information has been already changed Check the settings and request the setting of the configuration information again You are trying to register the same host group number as the already registered one 1067 0003 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again The specified host group has not bee...

Страница 24: ...y event that this error occurs contact HP technical support An error occurred If this problem persists call HP technical support 1 1 1 1 0003 6 E Change the volumes to create CV by VLL operation retry the VLL setting The specified volume is currently used by Parallel Access Volume and is not available for VLL operation 1 1 13 0003 2 E You have not specified the value when registering WWN Or zero i...

Страница 25: ...re no host groups where the WWN will be registered 1 125 0003 6 E Correct the specified contents and request again A volume set as a command device cannot be used as a component of a LUSE volume Select another volume 1 126 0003 2 E CHA high speed mode is specified to unmounted CHA The error does not occur normally because it is guarded in the screen In the unlikely event that this error occurs con...

Страница 26: ...et in a port 1 133 0003 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again Failed to set the path because the number of paths exceeds the maximum that can be set in a port 1 134 0003 2 E When PORT information Fibre Address Fibre Topology Channel Speed is set multiple change instructions are set to the same PO...

Страница 27: ... technical support 1 159 0003 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 1 169 0003 6 E Correct the settings and then retry The volume cannot be configured as a command device because the volume does not have Read Write attribute 1 170 0003 6 E Correct the settings and then retry Failed to set th...

Страница 28: ...st mode of the group with paths which are defined in the LU is corresponding to online LUSE 1 187 0003 6 E Correct the settings and then retry No information can be changed about this external port because the port has an external volume 1 194 0003 6 E Correct the settings and then retry You cannot set high speed mode to a package including an external port 1 197 0003 6 E Change the parameter to a...

Страница 29: ...f user LU settings has reached the maximum 1361 0003 5 W Check the port type and then retry the operation The port type is incorrect 1364 0003 6 E Wait a few seconds and then retry the operation The current Cache Residency setting cannot be changed because the sidefile size exceeds the threshold 1366 0003 6 E Check the settings and then retry The host mode 4C is used for a host group connecting to...

Страница 30: ...es in the volumes specified to compose a LUSE volume 1905 0003 6 E Select another volume The specified volume cannot be set as a command device because it is being used as a virtual volume 1906 0003 6 E Select another volume The specified volume contains XP Snapshot pairs 1910 0003 6 E Select another volume The specified volume contains Pool VOLs 191 1 0003 6 E Correct the settings and then retry ...

Страница 31: ... will be displayed Wait a few seconds and then click Refresh If this problem persists inconsistency of configuration may have occurred Call HP technical support If the problem occurred when starting SVP check the version number of the microcode and the configuration information Auto LUN QuickRestore etc are in process After you reply to this message a window that shows only the Refresh button will...

Страница 32: ...3 0003 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 2014 0003 6 E A communication error occurs If the error occurs after retrying call HP technical support An error occurred while connecting to the subsystem Wait for a while and then retry the operation 2015 0003 3 E Wait a few seconds and then ret...

Страница 33: ...t the host and execute the varyoffvg command Processing is disabled because the host is mounted or the device is reserved 2082 0003 2 E Check the DKC status and the current status of the configuration setting If necessary re execute the setting operation The subsystem status is invalid Call HP technical support 2083 0003 2 E Check the DKC status and the current status of the configuration setting ...

Страница 34: ...ither release the settings or stop the I Os and then retry the operation 2090 0003 6 W Stop the backup server and then retry The backup server of Business Copy ShadowImage for Mainframe or Compatible FlashCopy R is running Please stop the backup server and then retry the operation 2091 0003 6 W Split the XP Business Copy FlashCopy Mirroring XP Flex Copy XP pairs Some Business Copy ShadowImage for ...

Страница 35: ...tly running microcode version does not support the specified operation 2096 0003 6 E Stop executing I Os and then retry the operation The host specified by the WWN is performing I O operations 2097 0003 6 E Call HP technical support when the same problem persists The operation cannot be performed because the SVP microcode version does not match the DKCMAIN subsystem microcode version 2098 0003 6 E...

Страница 36: ...2 0003 6 E Delete or suspend all pairs to which the journal volumes belong Devices to be maintained include journal volumes Delete or suspend all pairs to which the journal volumes belong 2204 0003 6 E Delete all pairs to which the journal volumes belong Devices to be maintained include journal volumes Delete all pairs to which the journal volumes belong 2205 0003 6 E Correct settings and then ret...

Страница 37: ...y or ShadowImage for Mainframe reserve volume is defined Cancel the reserve volume and then retry the operation 2519 0003 6 E Cancel the pair definition and then retry the operation An Auto LUN pair is defined Cancel the pair definition and then retry the operation 2520 0003 6 E Cancel the pair definition cancel the reserve volume and then retry the operation An Auto LUN pair is defined Cancel the...

Страница 38: ...ror Number Part Code 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 2006 0004 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6000 0004 2 E The SVP reboots automatically If the error occurs after retryin...

Страница 39: ...all HP technical support 8010 0004 Table 5 Error Codes Part Code 0005 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5099 0005 6 E Install the program product This functionality is not available SNMP API is required ...

Страница 40: ...rver configuration is invalid Call HP technical support 4002 0006 Table 7 Error Codes Part Code 0007 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5013 0007 2 E An error occurred If this problem persists call HP tec...

Страница 41: ... invalid characters The characters that can be used for file names are single byte alphanumeric characters and symbols ASCII character set however the following characters cannot be used for file names In other cases wait for a while and retry the operation If the same problem persists despite retrying call HP technical support File access error occurred If a file is transferred between SVP and cl...

Страница 42: ...d then retry the operation Another user is downloading the file or transferring the file to the FTP server Wait for a while and then retry the operation 56546 0007 Table 8 Error Codes Part Code 0010 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 5 W Because the same user name is being used log in with the other user name The user ID is already logged in Do you...

Страница 43: ...l HP technical support A network error occurred The probable causes are The SVP was not ready An error occurred in the SVP A timeout error occurred during communication with the SVP 6027 0010 2 E Failed to connect from the server due to a network error etc Check the IP address A network error occurred 6060 0010 2 E You cannot connect to the SVP because of the factors such as a network error or SVP...

Страница 44: ...s problem persists call HP technical support 56003 0010 4 E Check the status of the file Alternatively check the status of the drive where the file will be saved and also check the free space on the drive An error occurred while writing to a file 56500 0010 0 W If this problem persists call HP technical support The temporary work file does not exist 56541 0010 1 E If this problem persists call HP ...

Страница 45: ...E Select another volume The specified volume cannot be set as a command device because it is being used as a virtual volume 1906 0105 6 E Select another volume The specified volume contains XP Snapshot pairs 1910 0105 6 E Select another volume The specified volume contains Pool VOLs 191 1 0105 3 W Check the status of the disk storage system if the storage system is blocked inconsistency of shared ...

Страница 46: ...s Copy ShadowImage for Mainframe FlashCopy Mirroring or XP Flex Copy settings or stop the I Os and then retry the operation Business Copy ShadowImage for Mainframe Compatible FlashCopy R or Flex Copy XP settings exist Release the settings or stop the I Os and then retry the operation 2090 0105 6 W Stop the backup server and then retry The backup server of Business Copy ShadowImage for Mainframe or...

Страница 47: ...ress in the target volumes issue the LISTSESS and LISTDVCS commands check the SESSION ID No and terminate SESSION by using the TERMSESS command The Concurrent Copy or the Compatible XRC operation is in progress in the target volumes Cancel the Concurrent Copy job or delete an Compatible XRC pair via the host 2200 0105 6 W Correct settings and then retry Processing cannot be performed because of Da...

Страница 48: ... then retry the operation 2515 0105 6 E Cancel or suspend the pair definition and then retry the operation A XP Continuous Access XP Continuous Access Journal or Universal Replicator for Mainframe pair is defined Cancel or suspend the pair definition and then retry the operation 2516 0105 6 E Split the pair and then retry the operation If the Quick Split mode is on suspend the pair and then split ...

Страница 49: ...support An error occurred during SVP processing If this problem persists call HP technical support 5013 0105 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5827 0105 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technic...

Страница 50: ...iled because all the paths to the external volume are blocked 8979 0105 6 E The licensed capacity for a program product will become insufficient because of a configuration change Add licensed capacity from the License Key window If you do not add licensed capacity in 10 days the program product will be unavailable The licensed capacity for a program product will become insufficient because of a co...

Страница 51: ...n The displayed information has not been changed 5030 01 10 5 i Purchase a new license The license for this product s will expire in d days Purchase a new license to continue using this product 5081 01 10 5 i Purchase a new license The license for this product s will expire in d days If the license expires you cannot continue using this program product Purchase a new license to continue using this...

Страница 52: ...and log in again A network error occurred the server is not ready or an error occurred in the server 6070 01 10 2 E Call HP technical support A client processing error occurred 7060 01 10 2 E If this problem persists call HP technical support An error occurred during processing If this problem persists call HP technical support 7440 01 10 5 E Retry the same operation several times If the same erro...

Страница 53: ...on of JRE The unsupported JRE version is used Install the supported version of JRE and then retry the operation 56503 01 10 7 E Return to the Modify mode and change the configuration again Modify mode released due to inactivity Another user or service engineer may have changed the configuration while the Modify mode was released Get back to the Modify mode and change the configuration again Set th...

Страница 54: ...ck Refresh All on the File menu and refresh the configuration information 67005 01 10 5 W Another user is accessing in Modify mode Wait for a while and then retry the operation Another user is accessing in Modify mode Wait for a while and then retry the operation 69007 01 10 5 i To continue processing click OK To stop processing click Cancel The setting may not be applied when another user is appl...

Страница 55: ... number 65535 and or and retry Enter the serial no with a number fewer than 65536 5015 0190 Enter the hostname with up to 255 alphanumeric characters Enter the hostname with up to 255 alphanumeric characters 5016 0190 Enter the hostname Enter the hostname 5017 0190 Remove the invalid characters and retry Only the following characters can be used a z A Z 0 9 5018 0190 Remove the multi byte characte...

Страница 56: ...HP technical support The storage list file does not exist 6005 0190 Call HP technical support The storage list file does not exist 6010 0190 If the same error occurs again despite retrying call HP technical support Failed to open the storage list file 601 1 0190 Call HP technical support The storage list file does not exist 6012 0190 None Failed to back up the storage list file 6013 0190 Specify t...

Страница 57: ...alid 55605 0210 5 W Enter the user ID Enter the user ID 55606 0210 5 W Enter a correct user ID Enter the user ID with up to 16 alphanumeric characters 55607 0210 5 W Specify a valid password The length of the character string of the specified password is invalid 55608 0210 5 W Specify a valid password The specified password is invalid 55609 0210 5 W Specify a valid password The new password is inv...

Страница 58: ...e you sure you want to register the parameters 55624 0210 5 W To change the write permission click OK Otherwise click Cancel Are you sure you want to change the write permission 55625 0210 5 W To change the password click OK Otherwise click Cancel Are you sure you want to change the password 55626 0210 5 W To change the user information click OK Otherwise click Cancel Are you sure you want to chan...

Страница 59: ...290 Input the correct password The password is invalid 5021 0290 Input the correct password The new password is invalid 5022 0290 Remove the invalid characters and retry You cannot use the following characters 5030 0290 Remove the multi byte characters and retry You cannot use multi byte characters 5040 0290 Register the other user ID The user ID is already registered 5050 0290 You cannot register...

Страница 60: ... the user account list file 6070 0290 If the same error occurs again despite retrying call HP technical support Failed to open the user account list file 6080 0290 Call HP technical support Failed to back up the user account list file 6090 0290 5 W Call HP technical support An error occurred while compressing a file 6091 0290 Set the correct password The password is invalid 6100 0290 Call HP techn...

Страница 61: ...r account list was modified by the administrator while you were making settings 6240 0290 Terminate the process and contact the administrator The user account list was modified by the administrator while you were making settings 6250 0290 If the same error occurs again despite retrying call HP technical support Failed to open the user account list file 6260 0290 If the same error occurs again desp...

Страница 62: ...the correct file name and then retry the operation File Name is invalid 56221 0290 Specify the correct file name and then retry the operation File Name is invalid 56231 0290 Specify the correct file name and then retry the operation File Name is invalid 56241 0290 Check more than one check box and then retry the operation No checkbox is checked 56301 0290 Specify the file name and then retry the o...

Страница 63: ...e file 56441 0290 If this problem persists call HP technical support Failed to extract files 56541 0290 If this problem persists call HP technical support Failed to create the file 5661 1 0290 If this problem persists call HP technical support Failed to create the file 56621 0290 If this problem persists call HP technical support Failed to create the file 56631 0290 If this problem persists call H...

Страница 64: ...oblem persists call HP technical support 7201 0305 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 7202 0305 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 7203 0305 2 E If this problem persists call HP ...

Страница 65: ...ons select a function button 56525 0305 6 E Correct the settings and then retry the operation The resources of other SLPR s cannot be accessed 56526 0305 5 W Correct the settings and then retry the operation 0 cannot be specified in all the fields 65685 0305 5 W Correct the settings and then retry the operation The SVP OS does not support IPv6 65686 0305 Table 15 Error Codes Part Code 0310 Failure...

Страница 66: ...9059 0310 5 W Confirm that the Trap has been received Trap transmission completed Wait for a while and check the reception of the Trap 69060 0310 Table 16 Error Codes Part Code 0405 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP techn...

Страница 67: ...ess Asynchronous XP Continuous Access XP Continuous Access Journal XP Continuous Access XP External Storage Access Manager Business Copy XP Snapshot Performance Monitor Performance Control Performance Monitor Auto LUN Universal Replicator for Mainframe Disaster Recovery Extended XP Continuous Access Journal Disaster Recovery Extended XP Compatible Hyper PAV XP Compatible Hyper PAV 5 W Retry again ...

Страница 68: ...s XP Continuous Access Asynchronous XP Continuous Access XP Continuous Access Journal XP Continuous Access XP External Storage Access Manager Business Copy XP Snapshot Performance Monitor Performance Control Performance Monitor Auto LUN Universal Replicator for Mainframe Disaster Recovery Extended XP Continuous Access Journal Disaster Recovery Extended XP Compatible Hyper PAV XP Compatible Hyper P...

Страница 69: ...Replicator for Mainframe Disaster Recovery Extended XP Continuous Access Journal Disaster Recovery Extended XP Compatible Hyper PAV XP Compatible Hyper PAV 5 W Call HP technical support This program product needs another DKC type 5079 0405 5 W Call HP technical support You cannot change this program product 5080 0405 5 W Select except ALL Normal Since the error occurred in another P P this P P was...

Страница 70: ... persists call HP technical support 6012 0405 3 W If the same problem persists despite retrying call HP technical support The SVP is busy Please wait for a while and then retry the operation 6022 0405 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6023 0405 6 W Stop the host I O Serverless Backup is ...

Страница 71: ...ror occurred during SVP processing If this problem persists call HP technical support 7203 0405 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 7204 0405 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 72...

Страница 72: ...rogram product To use the program product it needs to be enabled by installing additional shared memory 8204 0405 2 E Call HP technical support This program product remains in the configuration Call HP technical support 8205 0405 5 W Stop using this program product function This program product is in use you cannot uninstall this program 8206 0405 2 E Retry this operation The subsystem status is i...

Страница 73: ...ll HP technical support 57094 0405 3 E Install the program product by using another license key code A registered license key code was reinstalled 57095 0405 3 E The maximum number of licenses which can be registered to a program product is 1 024 The number of licenses of a program product has exceeded the maximum which can be registered 57096 0405 3 E If this problem persists call HP technical su...

Страница 74: ...ll HP technical support 6012 0407 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6023 0407 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 71 1 1 0407 Table 18 Error Codes Part Code 0410 Failure Level Se...

Страница 75: ...key and click OK The output process of the license key has completed 59301 0410 5 E Confirm the write permission and other settings of the file system and specify other directories or files The file output process has failed 59302 0410 5 i To continue processing click OK Otherwise click Cancel The specified file already exists Do you want to overwrite the existing file and then continue processing...

Страница 76: ...me problem persists despite retrying call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6012 0505 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6023 0505 2 E If this problem persists call HP technical support An error occurred during ...

Страница 77: ... 0505 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 71 1 1 0505 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 7201 0505 6 W Check the status of the disk storage system for example the storage system i...

Страница 78: ... this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5099 0507 2 E If the same problem persists despite retrying call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6012 0507 2 E If the same problem persists despite retrying call HP technical suppo...

Страница 79: ...us Access XP Business Copy ShadowImage for Mainframe XP Auto LUN or FlashCopy Mirroring pair is defined Release the pair definition and then retry the operation XP Continuous Access Business Copy ShadowImage for Mainframe Auto LUN or Compatible FlashCopy R pair is defined Release the pair definition and then retry the operation 2086 0605 3 W Take the storage system offline from the host The system...

Страница 80: ... processed due to the effect of the access attribute assigned by Volume Retention Check the settings and then retry the operation 2202 0605 5 E Processing cannot be performed because of the Volume Security settings Processing cannot be performed because of Volume Security settings 2203 0605 5 E Delete the journal volumes to be maintained and all the pairs that are using these journal volumes Journ...

Страница 81: ...e FlashCopy R pair Please split the pair and then retry the operation If a reserve volume is defined please cancel the reservation When quick split is in process suspend and then cancel the pair 2518 0605 6 E Cancel the reserve volume and then retry the operation A Business Copy or ShadowImage for Mainframe reserve volume is defined Cancel the reserve volume and then retry the operation 2519 0605 ...

Страница 82: ...ing SVP processing If this problem persists call HP technical support 6023 0605 5 W Wait a few seconds and retry the operation Processing in progress Wait for a while and then retry the operation 6502 0605 3 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6533 0605 5 E Decrease the number of external vo...

Страница 83: ...d Check the licensed capacity and specify a command within the licensed capacity or add the licensed capacity The command was rejected because the licensed capacity was exceeded Check the licensed capacity and specify a command within the licensed capacity or add the licensed capacity 8136 0605 5 E Confirm and operate the volume again This logical volume cannot be selected because it is used as a ...

Страница 84: ... error occurred on the DKC side If this problem persists call HP technical support 8960 0605 3 E An error occurred on the DKC side If this problem persists call HP technical support An error occurred on the DKC side If this problem persists call HP technical support 8961 0605 3 E An error occurred on the DKC side If this problem persists call HP technical support An error occurred on the DKC side ...

Страница 85: ...nd refresh the configuration An error occurred while connecting to the storage system The configuration may be inconsistent Click Refresh All on the File menu and refresh the configuration 8971 0605 5 E An error occurred on the DKC side If this problem persists call HP technical support An error occurred on the DKC side If this problem persists call HP technical support 8978 0605 5 E Restore more ...

Страница 86: ...ded To set the specified emulation type the cache segment size must be changed Call HP technical support 56513 0605 5 E Check the capacity of the volume The capacity of the specified volume is less than the minimum required to perform the Add Volume operation 56514 0605 5 E Execute the Disconnect Subsystem command or the Disconnect Volume command for the volume and then retry the operation Execute...

Страница 87: ...function cannot be used by the storage partition administrator 56524 0605 0 W Correct the licensed capacity with the License Key Partition Definition window The licensed capacity was exceeded because of changing the configuration Correct the licensed capacity on the License Key Partition Definition window 56536 0605 2 E If this problem persists call HP technical support An error occurred during SV...

Страница 88: ...normal status by executing Check Path Restore Volume and then retry the operation The cache mode cannot be changed when Disconnect Subsystem or Disconnect Volume is in progress 58409 0605 5 E Confirm the setting of the bind mode by Cache Residency Manager The cache mode cannot be changed because bind mode is set to the specified volume 58410 0605 5 E The cache modes of the volumes that compose the...

Страница 89: ...Call HP technical support The extended shared memory for External Storage is not installed 58905 0605 5 E Check the contents of the spreadsheet Specified PathGroup is not mounted 65791 0605 5 E Check the contents of the spreadsheet Specified PathGroup has already been mounted 65792 0605 5 E Check the contents of the spreadsheet Specified PathGroup has already been used 65793 0605 5 E Check the con...

Страница 90: ...n type cannot be set because 3390 3 is set in the subsystem 66014 0605 5 E Check the status of the path and then retry the operation The specified path configuration cannot be applied Check the status of the path and then retry the operation 66015 0605 5 E Check the contents of the spreadsheet The number of volumes that can be defined has exceeded the maximum 66500 0605 5 E Check the contents of t...

Страница 91: ...ystem path configuration of the external volume defined in the PathGroup is invalid 66518 0605 5 E Check the contents of the spreadsheet The number of WWNs that can be registered has exceeded the maximum 66519 0605 5 E Check the contents of the spreadsheet Mainframe volume and intermediate volume cannot be set because the package for mainframe system is not mounted 66520 0605 5 E Check the content...

Страница 92: ... invalid 66703 0605 5 E Check the contents of the spreadsheet The format of PortID is invalid 66704 0605 5 E Check the contents of the spreadsheet The value entered as PortID is outside the setting range 66705 0605 5 E Check the contents of the spreadsheet The number of digits of WWN is invalid 66706 0605 5 E Check the contents of the spreadsheet The format of WWN is invalid 66707 0605 5 E Check t...

Страница 93: ...ide the setting range 66724 0605 5 E Check the contents of the spreadsheet The number of digits of LDKC is invalid 66734 0605 5 E Check the contents of the spreadsheet The format of LDKC is invalid 66735 0605 5 E Check the contents of the spreadsheet The value entered as LDKC is outside the setting range 66736 0605 5 E Check the contents of the spreadsheet The number of digits of CU is invalid 667...

Страница 94: ...rs and delete all the V VOLs XP Snapshot Pool Groups and XP Thin Provisioning Pool Groups 68731 0605 5 E Release the association of the XP Thin Provisioning volume and the pool to be maintained The XP Thin Provisioning volume associated with a pool is included in the items to be maintained Release the association of the XP Thin Provisioning volume and the pool to be maintained 68732 0605 5 E Delet...

Страница 95: ...volume Release the bind mode setting if there is a volume whose cache mode cannot be changed because the bind mode is set 68742 0605 5 E Wait for XP Auto LUN or Quick Restore to be completed and then retry the operation Auto LUN or Quick Restore is in progress 68800 0605 5 E The volume targeted for maintenance includes the System Disk being used in Quick Format Wait for the Quick Format to be comp...

Страница 96: ... E Check the states of the external volume and the mapping path Do not retry the operation until the states return to normal If the states cannot be restored to normal or if the problem persists despite retrying call HP technical support Failed to disconnect from the external volume 68903 0605 Table 23 Error Codes Part Code 0610 Failure Level Severity Level Recommended Action Error Message Error N...

Страница 97: ...ect operation click No To cancel the operation click Cancel Have you performed the Disconnect operation If you execute Delete Volume without executing the Disconnect operation while non reflected data exists on the cache the non reflected data is not reflected to the external volume 59014 0610 0 W Click OK The volume is mapped as a mainframe volume by the Add Volume operation Format the volume bef...

Страница 98: ...lume 59038 0610 5 E The licensed capacity for a program product will become insufficient because of a configuration change Add licensed capacity from the License Key window If you do not add licensed capacity in 10 days the program product will be unavailable The licensed capacity for a program product will become insufficient because of a configuration change Add licensed capacity from the Licens...

Страница 99: ...ped as a mainframe volume by the Add Volume operation The settings of the volume made at the external subsystem side are carried over Restore the volume before using it 59107 0610 0 W To continue the processing click OK To stop the processing click Cancel Are you sure you want to delete the specified policy file 69000 0610 0 W To overwrite the file click OK Otherwise click Cancel The specified fil...

Страница 100: ...69009 0610 0 W Change the path configuration so that mapping paths match cross subsystem paths The specified path configuration cannot be set 69010 0610 0 W The number of external volumes may have reached the maximum or the virtual parity group VPG that can be set after the specified external volume group ExG does not exist Check the setting A virtual parity group VPG cannot be allocated to the ex...

Страница 101: ...lure Level Severity Level Recommended Action Error Message Error Number Part Code 5 W Reply to the message 0 cannot be specified in all the fields or the Class A field 5501 1 0710 0 W Set a different value for the IP address and the port number The value of the IP address and the port number of the primary syslog server are the same as the ones of the secondary syslog server 55596 0710 0 W Click O...

Страница 102: ...1005 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again The following volumes cannot be specified when you change the path configurations Volumes that do not exist Volumes other than the top LUs in expanded LUs Volumes reserved by Auto LUN System Disk volume 1005 1005 6 E Check the setting Failed to remove th...

Страница 103: ...mulation types of the volumes combined into a LUSE volume are not the same 1013 1005 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again LU path is set to the releasing expanded LU You need to release the expanded LU and path at the same time 1015 1005 2 E The specified port does not exist You have specified a...

Страница 104: ...support An error occurred If this problem persists call HP technical support 1023 1005 2 E Fibre topology information is invalid The specified value is not in the specification The error does not occur normally because it is guarded in the screen In the unlikely event that this error occurs contact HP technical support An error occurred If this problem persists call HP technical support 1024 1005 ...

Страница 105: ...ady in use Specify another WWN 1063 1005 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again You are trying to register the same WWN as the already registered one Check the settings and request the setting of the configuration information again 1064 1005 6 E Correct the specified contents and request the setti...

Страница 106: ... support 1 1 1 1 1005 2 E You have not specified the value when registering WWN Or zero is set as the WWN value The error does not occur normally because it is guarded in the screen In the unlikely event that this error occurs contact HP technical support An error occurred If this problem persists call HP technical support 1 1 16 1005 6 E The configuration information has been already changed Chec...

Страница 107: ...ps can be set because the number of host groups has reached the maximum 254 that can be set in a port Reduce the number of host groups and then retry the operation No more host groups can be set because the number of host groups has reached the maximum 254 that can be set in a port 1 131 1005 6 E The configuration information has been already changed Check the settings and request the setting of t...

Страница 108: ...umber of LUSE volumes exceeds the maximum that can be set in a disk array subsystem 1 137 1005 2 E An error occurred If this problem persists call HP technical support An error occurred If this problem persists call HP technical support 1 138 1005 2 E Release the Port Group setting Because the Port Group setting is done it is impossible to change Release the Port Group setting 1 140 1005 6 E Corre...

Страница 109: ...iguration information has been already changed Check the settings and request the setting of the configuration information again You cannot expand the LU because the host mode of the group with paths which are defined in the LU is corresponding to online LUSE 1 187 1005 6 E Correct the settings and then retry the operation To define a path to the volume from an iSCSI port the volume must be read w...

Страница 110: ...rt because of the attribute of the port 1351 1005 6 E Because the port you are trying to set is for XP Continuous Access you must delete the logical path and then retry the port setting Logical paths remain on the Fibre MCU port This operation may cause a fatal damage to the logical paths Please stop this operation If you want to continue this operation please remove the logical paths from the MCU...

Страница 111: ...type is incorrect 1364 1005 6 E Check the settings and then retry The host mode 4C is used for a host group connecting to volumes that cannot be used for External Storage 1367 1005 6 E Check the settings and then retry The host mode 4C can only be used with External Storage volumes 1368 1005 3 W Check the setting of the host mode option The specified host mode option can be set only for a specific...

Страница 112: ... E Check the setting The path cannot be set to the specified volume because the volume is being used as a quorum disk 1926 1005 6 E Check the setting The specified volume cannot be set as a command device because it is being used as a quorum disk 1927 1005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical suppo...

Страница 113: ...specified by the WWN is performing I O operations 2097 1005 6 E Call HP technical support when the same problem persists The operation cannot be performed because the SVP microcode version does not match the DKCMAIN subsystem microcode version 2098 1005 6 E Wait a few seconds and then retry the operation If the same problem persists call HP technical support The operation cannot be performed becau...

Страница 114: ...retry the operation If the same problem persists despite retrying please call the Support Center An error occurred 4436 1005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5010 1005 2 E Retry the operation If this problem persists call HP technical support An error occurred during SVP processing If t...

Страница 115: ... 1005 6 E Retry the same operation several times If the same error occurs call HP technical support This function is not supported 8102 1005 6 E Check the settings and then retry the operation The configuration information being set does not match the current configuration information Check the settings and then retry the operation 55206 1005 2 E If this problem persists call HP technical support ...

Страница 116: ...l support An error occurred during SVP processing If this problem persists call HP technical support 57101 1005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 57102 1005 6 E If this problem persists call HP technical support An error occurred while connecting to the subsystem Wait for a while and the...

Страница 117: ...0 5 W Correct the specified contents and request the setting of the configuration information again The specified host group is already used 1065 1010 5 W Correct the specified content and retry The specified LDEVs and free LUNs should be the same number 5010 1010 5 W You cannot specify any more The number of LU paths in use has already reached the maximum 2 048 in a Fibre Channel environment 5040...

Страница 118: ...1010 5 W Correct the settings and then retry It is not updated 5823 1010 5 W Release the reserved attribute of the target volume by using Data Retention Utility The specified volume cannot be manipulated because it is reserved by RAID Manager 5867 1010 0 W Correct the mode of the target group The host mode is invalid Specify a correct host mode 6509 1010 2 E Call HP technical support An error occu...

Страница 119: ...f they are running Are you sure to proceed 55234 1010 5 E To continue processing click OK To stop processing click Cancel The setting extends across multiple SLPRs Do you want to continue 59049 1010 5 E To continue processing click OK To stop processing click Cancel The setting extends across multiple SLPRs Do you want to continue 59050 1010 5 i Set the host mode option when it is necessary When a...

Страница 120: ...5 W Correct the specified content and retry The name should be input using specified letters a z and A Y and digits 0 9 5001 1 1 10 5 W Correct the specified content and retry The Group Name should be from 1 to 8 characters 5020 1 1 10 5 W Correct the specified content and retry The name should be from 1 to 8 characters 5021 1 1 10 5 W Correct the specified content and retry Each area of the WWN s...

Страница 121: ...057 1 1 10 5 W Check the content of the operation The WWN already has the same LUN group 5058 1 1 10 5 W Check the content of the operation The system cannot add WWN to LUN group 5060 1 1 10 5 W Check the content of the operation The system cannot add WWN to WWN 5061 1 1 10 5 W Check the content of the operation The WWN already exists in the port 5062 1 1 10 5 W Check the content of the operation ...

Страница 122: ...018 1 1 10 0 i The specified Host Group will be deleted Do you want to continue 9060 1 1 10 0 i The specified host will be deleted Do you want to continue 9061 1 1 10 0 i Warning The LU path to the LDEV will be released at once Do you want to continue 9063 1 1 10 0 i Do you want to remove the WWN 9064 1 1 10 0 i Do you want to remove all of the WWNs from the WWN group 9065 1 1 10 0 i Do you want t...

Страница 123: ... 1 1 10 5 W Correct the settings and then retry the operation The specified Target name is incorrect If the type of the Target name is eui specify the name in 20 characters The characters can be any combinations of the following starting with eui numerals 0 9 letters from A to F a to f If the type of the Target name is iqn specify the name within 223 characters The characters can be any combinatio...

Страница 124: ...sary Call HP technical support A communication time out error occurred 8001 1205 3 E An error occurred on the DKC side If this problem persists call HP technical support An error occurred on the DKC side If this problem persists call HP technical support 8966 1205 5 W Reboot the SVP computer and retry the request If this problem persists call HP technical support Obtain trace information by using ...

Страница 125: ... Message Error Number Part Code 2 E An error occurred during SVP processing If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5013 1305 2 E An error occurred during SVP processing If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP tech...

Страница 126: ... 5 W Correct the settings and then retry the operation The secret is incorrect 5833 1310 5 W Correct the settings and then retry the operation The reentered secret does not match the previously entered secret 5834 1310 5 W Correct the settings and then retry the operation The same user name is already registered 5835 1310 5 W Correct the settings and then retry the operation The user name or the s...

Страница 127: ...m persists call HP technical support An error occurred during processing If this problem persists call HP technical support 69050 1310 5 E Re create the authentication information using the authentication information creation tool Authentication information is invalid 69051 1310 5 E An error occurred in the client processing See the message displayed in the console for details See also the trouble...

Страница 128: ...call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 1010 2005 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again LU path is set to a volume which links as an expanded LU 1012 2005 2 E The emulation type of a volume that links as an expanded LU i...

Страница 129: ...um that can be set in a disk array subsystem 1 137 2005 6 E Check the specified contents The specified LDEV is already used for another LUSE volume 1 138 2005 2 E Check the setting The capacity of LUSE volume exceeds the maximum 1 182 2005 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again You are trying to i...

Страница 130: ...ct another volume There are virtual volumes and non virtual volumes in the volumes specified to compose a LUSE volume 1905 2005 6 E Check the volume and then retry the operation The specified volume is not a LUSE volume 1921 2005 6 E Restore the LDEVs and then retry the operation LDEVs that are not normal are included in the component of a LUSE volume 1922 2005 6 E Check the setting The LDEVs to b...

Страница 131: ...m status is invalid Call HP technical support 2084 2005 6 E Call HP technical support when the same problem persists The operation cannot be performed because the SVP microcode version does not match the DKCMAIN subsystem microcode version 2098 2005 6 E Wait a few seconds and then retry the operation If the same problem persists call HP technical support The operation cannot be performed because a...

Страница 132: ... a pool Associate the XP Thin Provisioning volumes and a pool first 65660 2005 6 E Select another volume XP Thin Provisioning volume s cannot be combined into LUSE volumes 65672 2005 6 E Associate the XP Thin Provisioning volumes with the same pool and then retry the operation The XP Thin Provisioning volumes are not associated with the same pool Associate the XP Provisioning volumes with the same...

Страница 133: ...ath to LUSE volume 5053 2010 5 W Check the content of the operation More than 36 volumes cannot be combined to form a LUSE 5054 2010 5 W Follow the correct operation procedure The size of the LUSE volume exceeds 64 424 505 600 KB 5055 2010 5 W Follow the correct operation procedure The specified LDEV is inaccurate 5056 2010 5 W Click OK to continue the operation Click Cancel to stop the operation ...

Страница 134: ...dministrator will become unable to operate Do you want to continue 55034 2010 5 W Delete the path set to the LUSE volume and then retry the operation The LUSE volume configuration cannot be released because a path is set to the LUSE volume Delete the path and then release the LUSE volume configuration 551 12 2010 Table 34 Error Codes Part Code 3005 Failure Level Severity Level Recommended Action E...

Страница 135: ...88 3005 6 W Make sure that there is an alternative path from the MCU The corresponding CHA might contain the last path between the MCU and RCU of XP Continuous Access Make sure that there is an alternative path from the MCU 2089 3005 6 W XP Business Copy ShadowImage for Mainframe or FlashCopy Mirroring settings exist Release the settings or stop the I Os and then retry the operation Business Copy ...

Страница 136: ...e XRC operation is in progress in the target volumes cancel the Concurrent Copy job or delete a Compatible XRC pair via the host If the Concurrent Copy or the Compatible XRC operation is not in progress in the target volumes issue the LISTSESS and LISTDVCS commands check the SESSION ID No and terminate SESSION by means of the TERMSESS command The Concurrent Copy or the Compatible XRC operation is ...

Страница 137: ...al support 2512 3005 6 E Release the pair definition or delete command devices defined by Business Continuity Manager and then retry the operation One of the following is defined a XP Continuous Access pair a XP Continuous Access Journal pair or a Universal Replicator for Mainframe pair Alternatively command devices defined by Business Continuity Manager are included Please release the pair defini...

Страница 138: ...e reservation and then retry the operation An Auto LUN pair is defined Please delete the pair definition If a reserve volume is defined please cancel the reservation and then retry the operation 2521 3005 6 E Cancel the reservation and then retry the operation The volume is reserved by Auto LUN Please cancel the reservation and then retry the operation 2522 3005 2 E If this problem persists call H...

Страница 139: ...support 6023 3005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6024 3005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6036 3005 2 E If nothing changes despite retrying call HP technical support An e...

Страница 140: ...ation may be inconsistent Click Refresh All on the File menu and refresh the configuration An error occurred while connecting to the storage system The configuration may be inconsistent Click Refresh All on the File menu and refresh the configuration 8971 3505 6 E Restore more than one path to the external volume and then perform the operation of the external volume The operation of the external v...

Страница 141: ... 55513 3005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 55514 3005 6 E Install the program product This function is not available because the program product is not installed 55516 3005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem p...

Страница 142: ...ed 56526 3005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 57101 3005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 57102 3005 6 E Install the logical volume The logical volume cannot be registered b...

Страница 143: ...ormation cannot be acquired do the following Check the installation status of the V VOL management area when the V VOL management area is not initialized Check the installation status of the V VOL management area when the V VOL management area is not installed Acquisition of the pool information has failed Pool information cannot be acquired when V VOL management area is not initialized V VOL mana...

Страница 144: ...s not supported 58573 3005 6 E If this problem persists call HP technical support An error occurred while connecting to the subsystem Wait for a while and then retry the operation 58574 3005 6 E If this problem persists call HP technical support An error occurred while connecting to the subsystem Wait for a while and then retry the operation 58575 3005 3 E If this problem persists call HP technica...

Страница 145: ...etry the operation The association cannot be released because paths are defined to the target volumes 65677 3005 6 E Release the LUSE setting and then retry the operation The association cannot be released because a LUSE setting is made on the target volumes 65678 3005 6 E Make sure that the volumes are not reserved for XP Auto LUN and then retry the operation The association cannot be released be...

Страница 146: ...support An error occurred during SVP processing If this problem persists call HP technical support 65695 3005 6 E Select only the volumes that can be formatted and format the volumes The specified volumes contain volumes that cannot be formatted Select only the volumes that can be formatted and format the volumes 65717 3005 6 E Check the specified volume The specified volume contains a quorum disk...

Страница 147: ...he formatting operation has completed LDEV format is being executed in the specified volume Retry the operation after the formatting operation has completed 68729 3005 6 E Wait for a while and then retry the operation to the logical volumes where the error occurred Wait for a while and then retry the operation to the logical volumes where the error occurred 68736 3005 6 E Check the current configu...

Страница 148: ...ent area if the V VOL management area is not installed Delete the XP Snapshot pair if the pair still remains in the pool Delete the XP Snapshot pair if the P VOL still remains in the pool Check the status of the pool VOL in the pool and restore the pool VOL if it is blocked Click Refresh or Refresh All on the File menu of the Remote Web Console window confirm that the amount of usage in the pool i...

Страница 149: ...rt The specified volume cannot be processed because it is blocked Recover the volume and then retry the operation 68819 3005 6 E Associate the volume with a pool and then retry the operation If this problem persists call HP technical support The specified volume cannot be processed because it is not associated with a pool Associate the volume with a pool and then retry the operation 68820 3005 6 E...

Страница 150: ...itional configuration Back up 68865 3005 6 E Release the quorum disks and then retry the operation Quorum disks are included in the items to be maintained 68884 3005 6 E Restore the pool that has been blocked by the XP Thin Provisioning function The item to be formatted includes an XP Thin Provisioning volume TP VOL However the TP VOL cannot be formatted because there is a pool that has been block...

Страница 151: ...n retry the operation Set a value that is 35MB 72 000 blocks or more 5012 3010 5 W Correct the specified content and retry There are no LDEVs which can be initialized Specify LDEVs which are not Auto LUN reserved volumes 5030 3010 5 W Correct the specified content and retry No LDEV is specified 5031 3010 5 W The specified value exceeds the maximum 5040 3010 5 W Check the content of the operation F...

Страница 152: ...ease the JNL settings from the volume release the quorum disk settings from the volume 5054 3010 5 W Check the content of the operation There is no volume to be initialized A volume cannot be initialized when it is defined with a path or paths used as a LUSE volume reserved for Auto LUN paired with another volume set as a command device used for Volume Security not read write enabled used as a Poo...

Страница 153: ... of LDEVs is not specified 5065 3010 5 E Check the content of the operation The specified size or number is invalid 5066 3010 5 E Check the content of the operation No write data is entered in the Define text box 5870 3010 5 E Check the content of the operation The number of entered characters is odd Enter even number of characters 5871 3010 5 E Check the content of the operation The number of tim...

Страница 154: ...o you want to apply 9102 3010 0 i Do you want to change 9103 3010 0 i Specify the SSID 9150 3010 5 i To continue processing click OK To stop processing click Cancel The specified volume will be shredded Are you sure you want to continue If the top LDEV of the LUSE volume is selected all the LDEVs that make up the LUSE volume will be shredded 9370 3010 5 i See the Shredding Complete Confirmation di...

Страница 155: ... of V VOLs exceeds the maximum number that can be set to the whole storage system 55588 3010 5 W Apply the Install CV setting and then retry the Install CV setting Only up to 16 384 LDEVs can be set when you apply the Install CV setting once You can only set another s LDEVs because the number of LDEVs that can be set in a VDEV is more than the number of LDEVs that can be set by Install CV setting ...

Страница 156: ...me is selected the status of all the LDEVs that make up the LUSE volume will be changed 59023 3010 0 i To format the volume click OK Otherwise click Cancel The specified volume will be formatted Are you sure you want to continue To select a LUSE volume select the top LDEV 59024 3010 5 i To continue Write to Control Blocks processing click OK Otherwise click Cancel Use this function only for zero f...

Страница 157: ...ost is not executed The blockade instruction for LDEV can be executed even in a state that there is I O from the host Check that I O from the host is not executed for the target LDEV to be blocked 65803 3010 6 E See the Shredding Complete Confirmation dialog box of the HP StorageWorks XP24000 XP20000 Virtual LVI LUN VLL and Volume Shredder User Guide The error occurred in shredding processing 6575...

Страница 158: ... and the encryption list will be displayed Click Cancel to return to the main window The information being set is not applied to the device The information will be cleared when the encryption list is displayed Do you want to continue 69069 3010 0 i When you have clicked OK button set the blue colored items again and apply them to the storage system When you have clicked Cancel button apply the blu...

Страница 159: ...ncel to stop processing Do you want to continue discard the changed setting and processing it 59312 31 10 5 i To continue processing click OK Otherwise click Cancel It will be added to the Pool VOL table with the specified contents Do you want to continue 59601 31 10 5 i To continue processing click OK Otherwise click Cancel Are you sure you want to delete the Pool 59602 31 10 5 i To continue proc...

Страница 160: ...t there is an alternative path from the MCU The corresponding CHA might contain the last path between the MCU and RCU of XP Continuous Access Make sure that there is an alternative path from the MCU 2089 3205 5 W Stop the backup server and then retry The backup server of Business Copy ShadowImage for Mainframe Compatible FlashCopy R is running Please stop the backup server and then retry the opera...

Страница 161: ... technical support 6012 3205 3 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6022 3205 3 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6023 3205 3 E If this problem persists call HP technical support An e...

Страница 162: ...em persists call HP technical support An error occurred on the DKC side If this problem persists call HP technical support 8952 3205 3 E An error occurred on the DKC side If this problem persists call HP technical support An error occurred on the DKC side If this problem persists call HP technical support 8953 3205 3 E An error occurred on the DKC side If this problem persists call HP technical su...

Страница 163: ... occurred on the DKC side If this problem persists call HP technical support 8964 3205 3 E An error occurred on the DKC side If this problem persists call HP technical support An error occurred on the DKC side If this problem persists call HP technical support 8965 3205 3 E An error occurred on the DKC side If this problem persists call HP technical support Technical support should see the trouble...

Страница 164: ...definition of XP Continuous Access and then retry the operation 56516 3205 5 E Release the setting of XP Business Copy ShadowImage for Mainframe FlashCopy Mirroring or XP Snapshot and then retry the operation The Business Copy ShadowImage for Mainframe Compatible FlashCopy R or XP Snapshot setting exists Release the setting and then retry the operation 56517 3205 5 E Release the reserve volume set...

Страница 165: ... used in Quick Format 68801 3205 5 E The volume targeted for maintenance includes a system disk being used by the audit log When you want to execute the operation set Audit Log Buffer to Disable which is located in the system disk option window of VLL The volume targeted for maintenance includes the System Disk being used in Audit Log 68802 3205 5 E The volume targeted for maintenance includes a s...

Страница 166: ...ne of the following errors occur The setting capacity of the V VOL is outside the range The number of created V VOLs is outside the range The number of V VOLs exceeds the maximum number of V VOLs that can be created in the whole subsystem The specified capacity exceeds the remaining capacity 55201 3210 5 W Check the settings and retry the operation There are V VOLs whose CU LDEV numbers are not se...

Страница 167: ...ol ID is not set when changing the threshold 65656 3210 5 W Do not select Free area Free area has been selected 65657 3210 5 W Release the Pool ID setting and then execute the operation The specified V VOL Group cannot be deleted because the group is associated to a pool 65658 3210 5 W Check the content of the operation The pool to be associated with is not selected 65666 3210 5 W Check the conten...

Страница 168: ...d volume and a volume not associated coexist in the V VOL group Make sure that an associated volume and a volume not associated do not coexist in the V VOL group prior to the association Do you want to continue 69042 3210 5 W To continue processing click Yes To stop processing click No The association of the Pool is released However an error will occur after the release of association when the V V...

Страница 169: ...ion 69057 3210 5 W To continue processing click Normal or Force To stop processing click Cancel The emulation type of an XP Thin Provisioning volume TP VOL that is set to OPEN V will change to OPEN 0V Execute the operation by selecting the following modes The temporary setting will be discarded Normal executes the operation only to the TP VOLs where paths are not set Force executes the operation t...

Страница 170: ... this error occurs contact HP technical support The specified emulation type of the customized volume CV is a type that cannot be combined 1038 3305 2 E Check the setting A path is defined to the specified volume 1039 3305 6 E Check and correct the settings If Volume Initialize and Make Volume are specified at the same time operate them separately The CU number and the LDEV number set in the VLL o...

Страница 171: ...L operation Subsystem ID cannot be set alone 1 104 3305 2 E Check the settings The number of volumes exceeds the maximum that can be set 1 105 3305 6 E Change the volumes ID to specify or release the Parallel Access Volumes setting The specified volume is currently used by Parallel Access Volumes and is not available for VLL operation 1 1 13 3305 2 E Check the setting of the specified volume The s...

Страница 172: ... during SVP processing If this problem persists call HP technical support 2005 3305 6 E Check the status of the disk storage system for example the storage system is blocked the shared memory is inconsistent or some other problem occurs If this problem persists call HP technical support The status of the storage system requires maintenance for example the subsystem is blocked the shared memory is ...

Страница 173: ...ine from the host 2087 3305 6 W Add an alternative path The XP Continuous Access pair is suspended Add an alternative path 2088 3305 6 W Be sure there is an alternative path from the MCU The corresponding CHA might contain the last path between the MCU and RCU of XP Continuous Access Make sure that there is an alternative path from the MCU 2089 3305 6 W XP Business Copy ShadowImage for Mainframe o...

Страница 174: ...ng Replacement of an OEM drive microprogram is in progress LDEV shredding is in progress Therefore the specified operation cannot be executed 2095 3305 6 E The Concurrent Copy or the Compatible XRC operation is in progress in the target volumes Cancel the Concurrent Copy job or delete a Compatible XRC pair via the host The Concurrent Copy or the Compatible XRC operation is in progress in the targe...

Страница 175: ...Universal Replicator for Mainframe pair Please release the pair definition or suspend the pair and then retry the operation 2516 3305 6 E Split the pair and then retry the operation If the Quick Split mode is on suspend the pair and then split the pair One of the following is defined a Business Copy pair a ShadowImage for Mainframe pair or a Compatible FlashCopy R pair Split the pair and then retr...

Страница 176: ... HP technical support An error occurred during SVP processing If this problem persists call HP technical support 3006 3305 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 3008 3305 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists c...

Страница 177: ...es in the current configuration and the setting 65661 3305 6 E Release the association of the XP Thin Provisioning volume and the pool to be maintained The XP Thin Provisioning volume associated with a pool is included in the items to be maintained Release the association of the XP Thin Provisioning volume and the pool to be maintained 65669 3305 6 E Delete the XP Thin Provisioning Pool Group that...

Страница 178: ... The format processing for the added volume has not been executed because the number of parity groups being quick formatted has exceeded the maximum Execute the format processing for the added volume To execute quick format processing execute after the quick format processing for other parity groups has completed 65694 3305 2 E Cancel the format or quick format processing from the SVP and then exe...

Страница 179: ...orum disk 65781 3305 6 E Check the specified volume The specified volume contains a JNL volume 65782 3305 6 E Check the specified volume The specified volume includes a remote command device being used by a mirror of the journal group 65790 3305 3 E Please contact the application program distributor A parity group to which 17 or more VDEVs are allocated exists The application program you are using...

Страница 180: ...red during SVP processing If this problem persists call HP technical support 5010 4005 6 W Reduce the number of requests and retry the operation The number of requests exceeds the maximum number that can be processed Reduce the number of requests and retry the operation 5040 4005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists...

Страница 181: ... inconsistent or some other problem occurs Call HP technical support 7202 4005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 7310 4005 6 E Check the settings and then retry the operation The total of Cache Residency size of the CLPRs and the total of all Cache Residency size in the subsystem are not...

Страница 182: ... persists call HP technical support 55533 4005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 55534 4005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 55535 4005 2 E If this problem persists call HP te...

Страница 183: ...gs and then retry the operation The resources of other SLPR s cannot be accessed 56526 4005 6 W Set the prestaging area by using Cache Residency to use the prestaging function The prestaging is not executed because the prestaging area does not exist Check the Cache Residency setting 56542 4005 6 E Wait a few seconds and then retry the operation The current Cache Residency setting cannot be changed...

Страница 184: ...ed Action Error Message Error Number Part Code 0 i Correct the specified content and issue the request again Part of the range is already in use 1030 4010 0 i Correct the specified content and issue the request again The specified value is outside the valid range 1032 4010 6 E Wait a few seconds click Refresh and change the same configuration again Or if the DKC status is not blocked check the DKC...

Страница 185: ...ou click Cancel Are you sure you want to reset the P P information 9340 4010 0 i To perform the prestaging operation click Yes To not perform the prestaging operation click No Prestaging will be carried out to the selected LDEV Do you want to continue 59035 4010 4 E Reduce the number of Extents in the LDEV The number of Extents in the LDEV has exceeded the maximum 65643 4010 Table 42 Error Codes P...

Страница 186: ...9 4105 3 E Select another window To set this function contact the storage administrator This function cannot be used by the storage partition administrator 56524 4105 3 E To continue the operation contact the storage administrator and have the settings across the multiple SLPRs cancelled and then retry the operation To perform other operations click a function button Because the settings across th...

Страница 187: ...ait for a while and then select the Refresh button 2033 5105 6 E Retry the same operation If the error occurs after retrying call HP technical support A connection error has occurred 2145 5105 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5010 5105 2 E If this problem persists call HP technical supp...

Страница 188: ...ring SVP processing If this problem persists call HP technical support 6023 5105 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6036 5105 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6092 5105 5 W Cha...

Страница 189: ... support 55500 5105 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 55501 5105 3 E Select another window To set this function contact the storage administrator This function cannot be used by the storage partition administrator 56524 5105 3 E To continue the operation contact the storage administrator...

Страница 190: ...stics of the volumes The CUs to be monitored are not specified If you continue the operation hyphens are displayed in place of performance statistics Do you want to continue the operation 69032 51 10 Table 45 Error Codes Part Code 5205 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 6 E Specify another volume The reserve attribute cannot be set to the specified...

Страница 191: ...volume s are already used by Auto LUN 1085 5205 6 E Check the microprogram version and call HP technical support The RAID level of the target volume is not supported 1086 5205 6 E Retry the operation after the format is completed The volume specified as a migration target is being formatted 1087 5205 6 E Specify another volume The volume specified as a migration source cannot be migrated because i...

Страница 192: ...fied volume is already used as a volume of Compatible XRC Specify another volume The volume s is already being used by Compatible XRC 1 122 5205 6 E Retry the same operation If nothing changes call HP technical support The volume types do not match 1207 5205 6 E Retry the same operation If nothing changes call HP technical support Auto LUN does not support the volume s 1208 5205 6 E Retry the same...

Страница 193: ...d was rejected due to one of the following reasons The volume specified as a migration target was blocked The volume specified as a migration target was used as a system disk 1217 5205 6 E Retry the operation after the format is completed The volume specified as a migration target is being formatted 1218 5205 6 E The command device cannot be used for XP Auto LUN Specify another volume The volume s...

Страница 194: ...l of the target volume is not supported 1228 5205 6 E See the Interoperability with Other Products section in the HP StorageWorks XP24000 XP20000 Auto LUN Software User s Guide when volume becomes available to migrate the volume of ShadowImage for Mainframe XP Business Copy or Compatible FlashCopy R The volume specified as a migration source is already used as a volume of ShadowImage for Mainframe...

Страница 195: ...olume specified as a migration target cannot be migrated because it is already used as a P VOL of ShadowImage for Mainframe XP Business Copy or Compatible FlashCopy R 1237 5205 6 E Specify another volume The volume specified as a migration target or a reserved volume cannot be migrated because it is already used as a volume of ShadowImage for Mainframe XP Business Copy or Compatible FlashCopy R 12...

Страница 196: ...S VOL Disable setting of Data Retention Utility The specified volume has Read Only Protect SVOL Disable setting of Data Retention Utility 161 1 5205 6 E Release the Read Only Protect S VOL Disable setting of Data Retention Utility The specified volume has Read Only Protect SVOL Disable setting of Data Retention Utility 1612 5205 5 W Confirm that a maintenance operation is not in progress and retry...

Страница 197: ...ssing If this problem persists call HP technical support 5013 5205 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5099 5205 6 W Install the required program product This functionality is not available because Auto LUN is not installed 5203 5205 6 E See the notes in the Interoperability with Other Pro...

Страница 198: ...05 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6001 5205 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6012 5205 2 E An error occurred If this problem persists call HP technical support If this prob...

Страница 199: ...all HP technical support Failed to get information from hihsmatm ini The file may not exist in the specified directory 7400 5205 6 E Retry the same operation several times If the same error occurs call HP technical support Failed to get information from hihsmpln ini The file may not exist in the specified directory 7401 5205 6 E Retry the same operation several times If the same error occurs call ...

Страница 200: ...urs call HP technical support The file contains invalid data 7412 5205 6 E Retry the same operation several times If the same error occurs call HP technical support The file hihsmpin ini contains invalid data 7413 5205 6 E Retry the same operation several times If the same error occurs call HP technical support The file hihsmpgr ini contains invalid data 7414 5205 6 E Retry the same operation seve...

Страница 201: ...or occurs call HP technical support Failed to delete all plans 7424 5205 6 E Retry the same operation several times If the same error occurs call HP technical support Failed to delete plan 7426 5205 6 E Retry the same operation several times If the same error occurs call HP technical support An error occurred while connecting to the subsystem Wait for a while and then retry the operation 8001 5205...

Страница 202: ...ngs of the specified volumes The specified volume migration plan cannot be executed because a volume on which VMA of Data Retention is set is paired with a volume on which VMA is not set 55060 5205 6 E Check the setting of the migration source volume and the migration target volume If the migration source volume is a normal volume a CVS volume of the same capacity as the migration source volume ca...

Страница 203: ... Confirm the setting of the specified volume The specified volume is used as a data volume by XP Continuous Access Journal or Universal Replicator for Mainframe 55259 5205 6 E Confirm the setting of the specified volume The volume s are already being used by Compatible FlashCopy R or FlashCopy Mirroring V2 55431 5205 6 E Confirm the setting of the specified volume The volume s are already being us...

Страница 204: ...ified volume The specified volume is used as a journal volume by XP Continuous Access Journal or Universal Replicator for Mainframe 55550 5205 6 E Check the setting of the specified volume The specified volume is used as a journal volume by XP Continuous Access Journal or Universal Replicator for Mainframe 55551 5205 6 E Confirm the setting of the specified volume The specified source volume is a ...

Страница 205: ... with different cache modes is invalid 55646 5205 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 56301 5205 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call the Support Center 56302 5205 2 E If this problem persists call HP t...

Страница 206: ...or a while and then retry the operation 58574 5205 6 E If the problem persists despite retrying call HP technical support An error occurred while connecting to the disk array Wait for a while and then retry the operation 58575 5205 3 E If the problem persists despite retrying call HP technical support A communication time out error occurred in the disk subsystem Wait for a while and then retry the...

Страница 207: ... it is an XP Thin Provisioning volume that is not associated with a pool 65705 5205 6 E Check the setting of the specified volume The specified volume cannot be moved because it is an XP Thin Provisioning volume that is not associated with a pool 65706 5205 6 E Check the setting of the specified volume The specified volume cannot be moved because it is an XP Thin Provisioning volume that is not as...

Страница 208: ...d volume Cannot migrate because the source volume is a XP Continuous Access Asynchronous volume or TrueCopy Asynchronous for Mainframe volume and also the CLPR numbers of the source volume and the target volume are not the same 65736 5205 6 E Check the specified volume capacity after the completion of the capacity expanding operation The specified volume cannot be used because it is a volume of XP...

Страница 209: ...annot be used because it is a quorum disk 65786 5205 Table 46 Error Codes Part Code 5210 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 5 W Change the monitor switch to ON and accumulate the data There is no monitoring data 5010 5210 0 i The history will be updated Do you want to continue 9010 5210 0 i To continue processing click OK To stop processing click C...

Страница 210: ...1 5210 5 W Increase the capacity if the pool associated with the target volume and then retry the operation The usage rate of the pool of target volume may exceed the threshold Do you want to continue 69056 5210 5 W Increase the size of the pool associated with the target volume The usage rate of the pool of target volume may exceed the threshold of pool Do you want to continue this operation 6906...

Страница 211: ...ng SVP processing If this problem persists call HP technical support 5013 5305 6 W Enter correct value Invalid value Enter correct value 5018 5305 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5099 5305 6 W Check the specified content and retry The target WWN is not registered 5101 5305 6 W Check th...

Страница 212: ...rocessing If this problem persists call HP technical support 6000 5305 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6012 5305 2 E If the error occurs after retrying call HP technical support A file open error has occurred 6022 5305 2 E If the error occurs after retrying call HP technical support A ...

Страница 213: ...ring SVP processing If this problem persists call HP technical support 55500 5305 2 E The error may be caused by a temporary communication failure Reboot the SVP or click Refresh All on the File menu of Remote Web Console and refresh the configuration information to recover from the error If this problem persists call HP technical support An error occurred during SVP processing If this problem per...

Страница 214: ...All on the File menu of Remote Web Console and refresh the configuration information to recover from the error If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 57101 5305 2 E The error may be caused by a temporary communication failure Reboot the SVP or click Refresh All on the File menu of Remote Web Cons...

Страница 215: ...sts call HP technical support An error occurred while connecting to the subsystem Wait for a while and then retry the operation 58575 5305 3 E The error may be caused by a temporary communication failure Reboot the SVP or click Refresh All on the File menu of Remote Web Console and refresh the configuration information to recover from the error If this problem persists call HP technical support A ...

Страница 216: ...n the non priority WWN 5069 5310 5 i Check the specified content and retry Target WWN is already registered in the port 5106 5310 5 i Check the specified content and retry The specified name is already used 5107 5310 5 i Check the specified content and retry The specified name is already used 5108 5310 5 i Check the specified content and retry The number of WWN s that is monitored exceeds the maxi...

Страница 217: ...click Cancel Are you sure you want to delete the Performance Control group 9078 5310 5 i To continue processing click OK To stop processing click Cancel The Performance Control group is deleted because no WWN is registered on the Performance Control group 9079 5310 5 W The control status will change to Port Control Click OK The control status will change to Port Control 9312 5310 5 W The control s...

Страница 218: ... you want to change the control status to No Control 9335 5310 0 i To continue processing click OK To stop processing click Cancel The Performance Control group extends across multiple SLPRs Do you want to continue 59000 5310 5 i Reduce the number of monitored WWNs in the ports being set as monitoring target at the same time and then retry the operation WWN cannot be registered because the number ...

Страница 219: ...the pair status is not changed after refreshing the window check the MCU or RCU configuration and the and the condition of the paths between the MCU and RCU The storage system accepted the request normally however the processing requires some time Wait for awhile and then refresh the window and confirm the pair status has been changed properly If the pair status is not changed after refreshing the...

Страница 220: ...ir status of the R VOL is not valid 8708 6005 4 E All channel adapters are not active for XP Continuous Access Call HP technical support XP Continuous Access operation was rejected 8709 6005 4 i The pair status does not permit this operation Verify the pair status and if the operation is permitted retry The pair status of the specified volume is not valid 8710 6005 4 i Check if the specified Port ...

Страница 221: ...4 i A maximum of four RCUs are permitted and that many already exist Too many RCUs Four RCUs are the maximum 8720 6005 4 E Check the path connections between the MCU and the RCU and then retry the operation Path not completely established 8721 6005 4 E Check the path connections between the MCU and the RCU and then retry the operation Failure during path creation 8722 6005 4 i Add another path or ...

Страница 222: ...the SSIDs are valid delete one or more and then retry the operation Too many SSIDs Only Four SSIDs are allowed 8732 6005 4 i Install the program product key in the MCU The Fibre XP Continuous Access function is not installed in the specified MCU 8733 6005 4 i Install the program product key in the RCU The Fibre XP Continuous Access function is not installed in the specified RCU 8734 6005 4 E Check...

Страница 223: ...U are not established 8741 6005 4 W Check the status of the M VOL tracks and clear the pinned tracks Pinned track s exists on the M VOL 8742 6005 4 W Check the status of the R VOL tracks and clear the pinned tracks Pinned track s exists on the R VOL 8743 6005 4 W The M VOL is not available for the requested operation because of one or more of the following reasons The volume is blocked The volume ...

Страница 224: ...es not support the specified function or operation Call HP technical support Current microprogram version does not support the specified operation 8747 6005 4 i Data migration cannot start because the volume is online Vary the path offline and retry Specified M VOL may be in use by HOST 8748 6005 4 i Check if the input number of R VOL is correct If not enter the correct R VOL number If the number ...

Страница 225: ...he track formats of the specified M VOL and R VOL M VOL and R VOL Track Formats do not match 8760 6005 4 W Verify the following items for the specified M VOL and R VOL If the emulation types match each other In the case of LUSE volume if the capacity of each volume combined in the LUSE matches each other In the case of mainframe system if the capacity of copy target is larger than that of copy sou...

Страница 226: ... i The R VOL option change operation failed only the M VOL option was modified because the RCU side does not support the display fence level function R VOL option change operation failed Only M VOL option was modified because RCU side did not support a fence level displaying function 8771 6005 4 E The pair option change operation failed either because a communication error occurred or because the ...

Страница 227: ...r Mainframe function is not installed in the specified controller 8780 6005 4 i Install TrueCopy for Mainframe in the MCU and RCU TrueCopy for Mainframe function is not installed in the specified controller 8781 6005 4 i Recheck the volume The M VOL is defined as the expansion volume 8785 6005 4 i Recheck the volume The R VOL is defined as the expansion volume 8786 6005 4 i Check the Port GID and ...

Страница 228: ...uous Access function is not installed in the specified controller s 8793 6005 4 i Install XP Continuous Access in the MCU and the RCU and then retry the operation The XP Continuous Access function is not installed in the specified controller s 8794 6005 4 i Check the status of the specified M VOL from the host or the SVP The operation failed because the specified M VOL applied to any of the follow...

Страница 229: ...shCopy R T VOL one S VOL must be paired with one T VOL 8797 6005 4 i The Add Pair operation failed because the MCU is already being used for XP Business Copy FlashCopy Mirroring Verify the status of the MCU and retry the operation The MCU is already used for ShadowImage for Mainframe Business Copy Compatible FlashCopy R 8798 6005 4 E Verify the status of the specified M VOL The M VOL is already in...

Страница 230: ... If an M VOL exists delete it and retry the add pair operation CT Group is not active in the RCU 8805 6005 4 i To change the CT group option timer type or time out either delete all asynchronous pairs in the group or verify the status of the RCU CT Group option and set the same option as the MCU CT Group Option cannot be changed unless deleting or suspending all asynchronous pairs in the group 880...

Страница 231: ...s of CT Group in the TrueCopy Asynchronous for Mainframe XP Continuous Access Asynchronous or XP Continuous Access Journal window of the MCU and RCU Add Pair Paircreate operation failed because TrueCopy Asynchronous for Mainframe pairs XP Continuous Access Asynchronous pairs or XP Continuous Access Journal pairs cannot be combined in one CT Group 8816 6005 4 i Cancel the preset suspension in the C...

Страница 232: ...he Add Pair Paircreate Resume Pair Pairresync operation failed combining pairs using Fibre path and Serial path is not allowed in the same CT Group 8825 6005 4 E Call HP technical support An internal error occurred 8826 6005 4 i Retry the operation in a few minutes If this problem persists select the volumes where the error occurred execute the Delete Pair Pairsplit S command with the Force option...

Страница 233: ...te more pairs purchase a license key that allows you to use a larger capacity The Add Pair Paircreate operation failed because you tried to create volume pairs which exceeded the licensed capacity of the RCU side 8835 6005 4 i Check the pair status and retry No additional volume pairs waiting for copy 8836 6005 4 E Call HP technical support An internal error occurred 8837 6005 4 i The specified vo...

Страница 234: ...tus transition 8844 6005 4 i Cancel the preset suspension in the CT group and then retry the operation Preset Suspension is effective in the CT Group 8845 6005 4 E Call HP technical support An internal error occurred 8846 6005 4 E Call HP technical support An internal error occurred 8847 6005 4 i The suspend pair Pairsplit r operation failed A few minutes later refresh the window confirm if the sp...

Страница 235: ... 8855 6005 4 i The operation failed because the status of the CT Group is SEQCHK Retry the operation with either the volume or the group option Delete Pair Pairsplit S operation failed because Consistency Time of CT Group is not determined by SEQCHK 8856 6005 4 i The operation failed for one or more of the volumes because either the pair status of the volume is SEQCHK or the consistency time of th...

Страница 236: ...curred 8866 6005 4 E Call HP technical support An internal error occurred 8867 6005 4 E The operation failed because a duplicate CT Group is already active in the MCU Verify the status of the CT group and retry the operation Duplicate CT Group A CT Group has been already active in MCU 8868 6005 4 E Verify that the CT group is active in the MCU CT Group is not active 8869 6005 4 i The group operati...

Страница 237: ...echnical support An internal error occurred 8884 6005 4 E Call HP technical support An internal error occurred 8885 6005 4 E Call HP technical support An internal error occurred 8886 6005 4 E Call HP technical support An internal error occurred 8887 6005 4 E Call HP technical support An internal error occurred 8888 6005 4 E Refresh the window and retry If nothing changes call HP technical support ...

Страница 238: ...installation instruction of the extended shared memory for remote copy Shared Memory Size Configuration dialog box and then create a pair If SM 2 is installed in MCU you cannot create any more pairs because the number of pairs has already reached the maximum that can be created by the system No more space is left in MCU for differential management 8904 6005 5 E Install the shared memory to the MCU...

Страница 239: ...on the port 891 1 6005 4 i The Remote Console computer detected a logical path z OS on the port Delete the paths and retry the operation Logical paths exist on the port 8912 6005 4 W Check the port status and retry Invalid port type 8913 6005 4 i The multi platform feature has already been installed in the storage system Verify the configuration of the storage system Multi platform feature already...

Страница 240: ... Check the port status and retry Invalid port type 8929 6005 4 E Delete the logical paths on the specified port and retry the operation Logical paths exist on the RCU port 8930 6005 4 E Delete the logical paths on the specified port and retry the operation Logical paths exist on the RCU port 8931 6005 5 W Check whether the specified LDKC number or CU number is defined as configuration information ...

Страница 241: ... the RCU is being changed to Simplex Suspend status Retry the operation a few minutes later 8943 6005 4 i Check the status of the specified R VOL The specified R VOL is not available according to the attribute of the R VOL changed by Data Retention Utility 8944 6005 4 W Verify whether the parameters of M VOL for example CU number port GID and LUN are supported with the RCU microcode program versio...

Страница 242: ...ied M VOL is a command device 8982 6005 4 i Specify the volume that can be used to create a pair and then retry the operation You cannot create a pair because the specified R VOL is a command device 8983 6005 4 E Check the settings and then retry the operation You cannot create a new pair because the number of CT groups of asynchronous pairs that you can register in SLPR exceeds the limit 8984 600...

Страница 243: ...ring V2 as an M VOL Cylinder was set for the Difference Management of the M VOL The Add Pair operation was executed specifying None for Initial Copy The M VOL belonged to Sync Group 8989 6005 4 i Specify the volume that can be used to create a pair and then retry the operation A pair cannot be created because the specified R VOL is used for Compatible FlashCopy V2 8990 6005 5 E Specify the port as...

Страница 244: ...tiple CLPRs 58321 6005 5 i Select another volume and retry the operation The pair cannot be created because the specified R VOL is a LUSE volume that is set across the multiple CLPRs 58322 6005 5 i To create a pair by using a volume without VMA you must only use volumes without VMA To create a pair by using a volume with VMA you must only use volumes with VMA A pair cannot be created because you t...

Страница 245: ...annot be created because the licensed capacity of Data Retention Utility on the MCU side is insufficient or Data Retention Utility is not installed on the MCU 58454 6005 5 i Use another volume or recreate the XP Continuous Access Journal pair or the Universal Replicator for Mainframe pair using a mirror ID other than 0 Then retry the operation The specified M VOL is already used as a primary data ...

Страница 246: ...Utility window and then retry the operation A pair cannot be created because the specified R VOL is being shredded by Data Retention Utility Retry the operation after the shredding is completed 58569 6005 5 i Execute the Delete Pair operation You cannot execute the Erase R VOL operation Execute the Delete Pair operation 58577 6005 5 i Check whether the number of the specified R VOL is correct or t...

Страница 247: ...ogram products are XP Continuous Access or TrueCopy for Mainframe XP Continuous Access Asynchronous or TrueCopy Asynchronous for Mainframe The licensed capacity of XP Continuous Access Asynchronous or TrueCopy Asynchronous for Mainframe on the RCU is insufficient Check the licensed capacity of this program product and the related program products The related program products are XP Continuous Acce...

Страница 248: ...5 0 W Check whether the specified R VOL is an XP Thin Provisioning volume The operation failed because the specified R VOL was used as an XP Thin Provisioning volume 68012 6005 0 W Confirm that no pairs are in COPY or Pending status and then retry the operation Maximum Initial Copy Activities CU cannot be changed to Enable or Disable because there are pairs in COPY or Pending status 68020 6005 0 W...

Страница 249: ...ger function was not installed 68788 6005 0 W Install XP Continuous Access to the RCU The Paircreate operation failed because the XP Continuous Access software was not installed in the RCU 68789 6005 0 W Install XP External Storage Access Manager to the RCU The Paircreate operation failed because the XP External Storage Access Manager function was not installed in the RCU 68790 6005 0 W Refresh th...

Страница 250: ... M VOL was an XP Thin Provisioning volume whose capacity was being changed 68813 6005 0 W The specified volume is a primary data volume of XP Continuous Access Journal which runs on the 2DC configuration in which XP Continuous Access or XP External Storage Access Manager cooperates Specify another volume A pair cannot be created because the specified volume is used as a primary data volume of the ...

Страница 251: ...ume is not a quorum disk 68830 6005 0 W Release all the pairs of XP External Storage Access Manager of the specified quorum disk ID and then retry the operation The operation failed because the specified quorum disk was used for XP External Storage Access Manager 68831 6005 0 W Retry the operation after the completion of discarding zero data on the specified volume The operation failed because the...

Страница 252: ...7 6005 0 W Select another volume or release the journal volume setting The operation failed because the specified volume was a journal volume 68878 6005 5 E Select another volume or release the pool volume setting The operation failed because the specified volume was a pool volume 68879 6005 5 E Select another volume or release the XP Auto LUN setting The operation failed because the specified vol...

Страница 253: ...m product for the specified pair The operation failed because of one of following reasons Specified the other program product for the pair of XP Continuous Access Specified the other program product for the pair of XP External Storage Access Manager 68895 6005 0 W Confirm the quorum disk ID status The operation failed because a quorum disk was not registered in the specified quorum disk ID 68899 6...

Страница 254: ...port 6036 6007 4 E Retry the operation If you get the same message again reboot the computer If necessary Call HP technical support A time out error occurred 8001 6007 Table 52 Error Codes Part Code 6010 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 5 W Correct the specified contents and retry The Priority value is invalid Specify the correct value 5010 6010 ...

Страница 255: ...5137 6010 0 W Check the contents and retry The value specified for Gathering Interval is invalid Specify a valid value within the range of 1 to 15 5138 6010 0 W Check the contents and retry The Script File Name value is invalid Specify the correct value 5139 6010 0 W Specify the correct CU number The specified CU number is incorrect Specify the correct CU number 5140 6010 0 W Specify the correct d...

Страница 256: ...ssing is complete reset the port that is not in operation The Port Setting process has not completed Do you want to continue for other ports 9021 6010 0 W Check the contents of the main and remote volumes If the contents match click OK If not click Cancel WARNING Initial copy mode None is selected for some volume pairs Are you sure that the M VOL and the R VOL of these pairs are already synchroniz...

Страница 257: ... you want to delete the specified CT groups 9076 6010 0 i To close the window click OK Otherwise click Cancel Do you want to exit 9100 6010 0 i To cancel click OK Do you want to cancel 9101 6010 0 i Click OK to execute the operation Do you want to apply 9102 6010 0 i Not used Do you want to change 9103 6010 0 i To switch the mode click OK If not click Cancel Do you want to change the mode 9104 601...

Страница 258: ...ncel The graph will be closed if you execute the processing Do you want to execute the processing 9120 6010 0 i To execute this operation click OK Otherwise click Cancel Data has been changed and the graph has been displayed If you continue this operation all the data and the graph will become invalid Are you sure you want to continue this operation 9121 6010 0 i To output pair status into a snaps...

Страница 259: ...ill not be changed If you do this operation change the R VOL status to SMPL later 9301 6010 0 W Set the port to RCP before registering RCU Moreover set up the correct range of CU numbers to which the RCP port is applied There are no RCP ports 9302 6010 0 W Confirm whether the command device for Business Continuity Manager is defined There are no valid volumes 9303 6010 0 W Follow the instructions ...

Страница 260: ... 1 6010 0 W Follow the instructions in the message Through this operation M VOL status will be changed to Simplex mode even if the M VOL is online to the host 9316 6010 0 W Follow the instructions in the message The destination volume of the specified volume pair may contain some inconsistency because volume copy is not completed yet Full volume initialization is required before re using it 9317 6...

Страница 261: ... and then retry the operation There are no consistency groups available for the CLPR of the specified volumes Register the consistency groups and then retry the operation 56537 6010 0 W Check the size of the file decrease the size and retry the operation The size of the specified file exceeds 8 megabytes so the file cannot be uploaded 56540 6010 0 W To cancel the change operation of the option par...

Страница 262: ...operation deletes all command devices for the Business Continuity Manager Are you sure you want to continue this operation 59340 6010 0 W Specify the correct LDKC number The specified LDKC number is incorrect Specify the correct LDKC number 65663 6010 0 W Specify another volume The specified volume is not valid for this program product Specify another volume 65664 6010 0 W Check the monitoring set...

Страница 263: ... and retry the operation An XP Thin Provisioning volume is contained in the selected volumes This volume cannot be used for XP Continuous Access Asynchronous or TrueCopy Asynchronous for Mainframe 68753 6010 0 W Check the LDKC number for the specified data volume and specify only one LDKC number There are two or more LDKC numbers for the specified data volume In this operation specify only one LDK...

Страница 264: ...8 6010 0 i To delete the file click OK To cancel the deletion click Cancel Are you sure you want to delete the selected file 69039 6010 0 W Call HP technical support after checking the version of the DKAMAIN microcode The current DKCMAIN microprogram cannot use XP External Storage Access Manager 69071 6010 0 W Install the XP External Storage Access Manager program product The operation cannot be e...

Страница 265: ...rsists call HP technical support 6000 6505 2 E Retry the operation If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6001 6505 3 E If the problem persists despite retrying call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6012 6505 2 E If th...

Страница 266: ...processing If this problem persists call HP technical support 8100 6505 3 E Check whether the DKCMAIN microcode version and the SVP microcode version are mismatched This function is not supported 8102 6505 4 i Retry the operation Retry operation 8700 6505 4 i Check the path status and edit the path again The logical path between the local and the remote subsystems is invalid 8701 6505 4 i Refresh ...

Страница 267: ...performing a pair operation check the DKC status wait until the SCP time elapses and then retry the operation The operation was rejected due to a FREEZE state 8712 6505 4 E Exchange the port type after deleting the group setting The port group already exists on the specified port 8713 6505 4 E Call HP technical support An internal error occurred 8714 6505 4 E Ensure that the number of paths is cor...

Страница 268: ...he error code is 100c add normal paths and then set the minimum number of paths If the error code is 100d add normal paths and then delete paths Alternatively reduce the minimum number of paths and then delete paths The number of minimum paths exceeds the number of normal paths 8727 6505 4 i Do either of the following to recover from the error If the error code is 100c add normal paths and then se...

Страница 269: ...Journal or Universal Replicator for Mainframe is not installed in the remote subsystem 8734 6505 4 E Check the serial number and the controller ID of this remote storage system and already registered remote storage systems and then specify the correct values If the specified values are correct check the cable connection of the remote storage system If the problem persists call HP technical support...

Страница 270: ...ondary data volume is being used by Compatible XRC The secondary data volume is being used by PPRC or XP Continuous Access The secondary data volume is being used by Concurrent Copy The access attribute of the secondary data volume is Read Only The secondary data volume is already in use by another system 8745 6505 4 i See the Installation and Open Platform sections in the maintenance manual to ch...

Страница 271: ...ed The journal volumes of the restore journal group were blocked 8764 6505 4 i Click OK to finish processing Then wait a few minutes and retry the operation The cache in the primary subsystem is automatically recovering 8770 6505 0 W Select another volume The primary data volume is already used by Compatible XRC 8776 6505 4 W Check the status of the cache in the secondary storage system Ensure tha...

Страница 272: ...me was a ShadowImage for Mainframe T VOL in non Split status The volume was a reserved volume The volume was in the Reverse Copy status 8795 6505 4 i Check the status of the secondary data volume from the host or the SVP The operation failed because the specified secondary data volume was one of the following An S VOL or reserved volume of Business Copy A T VOL or reserved volume of ShadowImage fo...

Страница 273: ... be specified as primary data volumes Check the status of the specified primary data volume from the host or the SVP The specified primary data volume is already reserved by Auto LUN 8830 6505 4 i Volumes reserved by XP Auto LUN cannot be specified as secondary data volumes Check the status of the specified secondary data volume from the host or the SVP The specified secondary data volume is alrea...

Страница 274: ...log and then call HP technical support An internal error occurred 8893 6505 4 E Stop the jobs from the host and retry the operation Jobs exist on the port 8894 6505 4 E Stop the jobs from the host and retry the operation Jobs exist on the port on the remote subsystem 8895 6505 4 E Refresh the window and retry If nothing changes call HP technical support Parameter error has occurred 8896 6505 4 E D...

Страница 275: ... system Failed to create the logical path because the configuration definition of the specified LDKC number did not exist in the primary storage system 8932 6505 0 W Check the configuration of the specified secondary data volume The Add Pair Paircreate operation failed because the specified secondary data volume was a NAS system volume 8934 6505 0 W Check the microcode version of the secondary sto...

Страница 276: ...number of requests to be processed at one time After that retry the operation 58005 6505 0 i Check the specified LDEV number Invalid parameter LDEV number 58006 6505 0 i Check the specified journal group number Invalid parameter journal group number 58007 6505 0 i Call HP technical support The command was rejected by the subsystem because the command is unknown 58008 6505 0 i Reduce the number of ...

Страница 277: ... number The specified CLPR number is incorrect 58023 6505 0 i Check the specified cache value for master journal groups The specified cache value for master journal groups is invalid 58024 6505 0 i Check the specified cache value for restore journal groups The specified cache value for restore journal groups is invalid 58025 6505 0 i Check the threshold for ending creation of asynchronous journal ...

Страница 278: ...too many volumes are selected 58035 6505 0 i Check the emulation type of the specified volume The device emulation type of the specified volume is not supported 58036 6505 0 i Check the status of the specified journal group The specified journal group cannot be deleted because a data volume exists 58037 6505 0 i Check the number of registered path group IDs No more path group IDs can be registered...

Страница 279: ... 6505 0 i Check the status of the specified volume The specified volume does not exist or is unusable 58078 6505 0 i Check the status of the specified primary data volume in the Volume Retention Manager window or the Data Retention Utility window The specified primary data volume cannot be used as an S VOL secondary volume because of Volume Retention Manager settings or Data Retention Utility sett...

Страница 280: ... differs from the registered mirror ID Check the combination of the primary journal group and the mirror ID 58088 6505 0 i Reduce the number of registered remote storage systems and then retry the operation No more remote subsystems can be registered 58089 6505 0 i Check the SLPR number of the specified data volume and the journal volume in the journal group The SLPR number of the specified data v...

Страница 281: ...ct check the cable connection of the remote storage system If the problem persists call HP technical support The serial number or the controller ID of the remote subsystem is incorrect 58100 6505 0 i Refresh the window and check the pair status The pair status is incorrect 58101 6505 4 E The pair status may be different in the primary storage and the secondary storage system Wait for a while and t...

Страница 282: ...of each volume combined in the LUSE matches each other The operation failed because the specified data volumes were in one of the following statuses The capacities of primary and secondary data volumes do not match LUSE volume is specified for the primary and the secondary data volumes and the capacity of each volume combined in the LUSE do not match each other 58106 6505 0 W Install XP Continuous...

Страница 283: ... specified secondary data volume is a mainframe volume The specified secondary data volume cannot be used because of the following reasons S VOL Disable is set by Data Retention Utility The VMA setting differs between the primary data volume and the secondary data volume Protection is set by Volume Retention Manager 58271 6505 0 i Check the status of the specified secondary data volume A Concurren...

Страница 284: ...he same 58279 6505 0 i Check the status of the specified secondary data volume The specified secondary data group is already registered 58280 6505 0 i Check the number of pairs in the specified restore journal group No more pairs can be registered in the specified restore journal group 58281 6505 0 i Identify the journal group where the specified secondary data volume is registered The specified s...

Страница 285: ... volume 58290 6505 0 i Check the status of the specified secondary data volume The specified secondary data volume is not paired with any another volume 58291 6505 0 W Check whether the journal volume is in any of the following conditions Data in the journal volume is being copied correction copy or drive copy is in progress The journal volume is in correction access condition The journal volume i...

Страница 286: ...ent Copy Compatible XRC or any of the following program products ShadowImage for Mainframe TrueCopy for Mainframe TrueCopy Asynchronous for Mainframe FlashCopy Mirroring XP Auto LUN The specified secondary data volume is used by Concurrent Copy Compatible XRC or another program product 58298 6505 0 W Check the configuration of the specified volume The specified volume is used as a command device 5...

Страница 287: ... is in COPY or Pending status retry the operation after the status of the volume changes to PAIR or Duplex The specified primary data volume is used by XP Continuous Access XP External Storage Access Manager or TrueCopy for Mainframe The operation failed because the status of the XP Continuous Access pair the XP External Storage Access Manager pair or the TrueCopy for Mainframe pair was inappropri...

Страница 288: ... number of the specified volume is different from the CLPR number of the journal volume that has already been registered 58336 6505 0 W Check the CLPR number of the journal volume in the specified master journal group and specify the primary data volume that has the same CLPR number The Add Pair Paircreate operation failed because the CLPR number of the specified primary data volume was different ...

Страница 289: ... enabled The microcode version of the secondary subsystem does not support external volumes 58345 6505 0 W From the Data Retention Utility window check the settings of the specified secondary data volume The Paircreate operation failed because a Data Retention Utility VMA was set up on the specified secondary data volume 58346 6505 0 W Check the setting of the specified secondary data volume in th...

Страница 290: ...dowImage for Mainframe A P VOL of Business Copy in Swap or Reverse Copy status An S VOL of ShadowImage for Mainframe in Swap or Reverse Copy status A P VOL of Business Copy used in conjunction with XP Continuous Access A P VOL of Business Copy used in conjunction with XP External Storage Access Manager An S VOL of ShadowImage for Mainframe or Compatible FlashCopy R used in conjunction with TrueCop...

Страница 291: ...opy R 58455 6505 5 W Verify the status of the specified primary data volume from the Compatible FlashCopy R window or the mainframe host The Add Pair operation or the Resume Pair operation failed because the specified primary data volume was a volume of PreserveMirror FlashCopy for Compatible FlashCopy R V2 58456 6505 0 W Specify a mirror ID other than 0 and then retry the operation XP Continuous ...

Страница 292: ...system and call HP technical support to confirm whether the microcode supports the change pair option function If the microcode supports the function call HP technical support because a communication error might have occurred Only the pair option of the primary data volume was updated Failed to update the pair option of the secondary data volume 58490 6505 5 W Check the DKCMAIN microcode version o...

Страница 293: ...rcreate operation failed because the IO suppression mode of the specified primary data volume was enabled 58508 6505 0 W Check the mirror ID assigned to the specified primary data volume number LDKC CU LDEV from the secondary storage system and assign a mirror ID that is not used and retry the operation The Add Pair Paircreate operation failed The combination of the specified primary data volume n...

Страница 294: ... Volume 58553 6505 0 W Call HP technical support to install additional shared memory A journal volume cannot be added because the capacity of shared memory is insufficient 58560 6505 0 W Check the timer type of the master and the restore journal group The Add Pair operation or the Resume Pair operation failed because the timer type of the master journal group was different from the timer type of t...

Страница 295: ...air Pairresync operation failed because the journal volumes of the specified master journal group were blocked 58590 6505 0 W Check the status of the journal volumes of the specified restore journal group The Add Pair Paircreate operation or the Resume Pair Pairresync operation failed because the journal volumes of the specified restore journal group were blocked 58591 6505 0 W Check the status of...

Страница 296: ...se the Universal Replicator for Mainframe function or Disaster Recovery Extended function is not installed 58600 6505 0 W Call HP technical support and install additional shared memory Journal groups cannot be added to the extended consistency group EXCTG because the additional shared memory was not installed 58601 6505 0 W Check the number of storage systems in the specified extended consistency ...

Страница 297: ... 58609 6505 0 W Refresh the window and then retry the operation If this problem persists call HP technical support The parameter specified in the extended consistency group EXCTG operation is invalid 58610 6505 0 W Retry the operation after the microcode exchange completes The specified operation failed because the microcode exchange was in progress on the subsystem in the extended consistency gro...

Страница 298: ...en retry the operation 58620 6505 0 W Check the attribute of the specified journal group Journal groups cannot be added to the extended consistency group EXCTG because the attribute of the specified journal group is invalid 58621 6505 0 W Check whether the specified command device of the specified serial number exists Journal groups cannot be added to the extended consistency group EXCTG because t...

Страница 299: ...ge system and call HP technical support to confirm whether the XP Continuous Access Journal or the Universal Replicator for Mainframe function supports the Delta resync function The operation failed because the XP Continuous Access Journal or the Universal Replicator for Mainframe function of the secondary subsystem does not support the Delta resync function 58683 6505 0 W Check the status of the ...

Страница 300: ...ata volume of XP Continuous Access or TrueCopy for Mainframe or the pair status of the primary data volume was invalid 58685 6505 0 W Check the attribute of the journal group of the remote storage system The specified operation failed because the attribute of the journal group of the remote subsystem was not restore 58686 6505 0 W If the problem persists despite retrying call HP technical support ...

Страница 301: ...ecified master journal group is registered in the extended consistency group EXCTG 58692 6505 0 W Check the status of the restore journal group The specified restore journal group cannot be used for Delta resync because the specified restore journal group is registered in the extended consistency group EXCTG 58693 6505 0 W Check the status of the secondary data volume or the status of the connecte...

Страница 302: ...by one of the following program products Business Copy ShadowImage for Mainframe Compatible FlashCopy R FlashCopy Mirroring V2 XP Snapshot 58699 6505 0 W Check the status of the specified secondary data volume The operation to change the status to the status ready for Delta resync failed The specified secondary data volume should meet the following requirements The specified volume is a secondary ...

Страница 303: ...the specified secondary data volume The Add Pair Paircreate operation or the Resume Pair Pairresync operation failed because the status of the specified secondary data volume was Not Ready 58707 6505 0 W If the same problem persists despite retrying call HP technical support The Add Pair Paircreate operation to get ready for Delta resync failed or the recovery to the status ready for Delta resync ...

Страница 304: ...acities The related program products are XP Continuous Access or TrueCopy for Mainframe XP Continuous Access Journal or Universal Replicator for Mainframe The licensed capacity of XP Continuous Access Journal or Universal Replicator for Mainframe on the RCU is insufficient Check the licensed capacity of this program product and the related program products The related program products are XP Conti...

Страница 305: ...e XP Continuous Access Journal or Universal Replicator for Mainframe The licensed capacity of XP Continuous Access Journal or Universal Replicator for Mainframe on the MCU is insufficient Check the licensed capacity of this program product and the related program products The related program products are XP Continuous Access or TrueCopy for Mainframe XP Continuous Access Journal or Universal Repli...

Страница 306: ...upported 66600 6505 5 E Check the contents of the spreadsheet The number of digits of CU S VOL is invalid 66601 6505 5 E Check the contents of the spreadsheet The format of CU S VOL is invalid 66602 6505 5 E Check the contents of the spreadsheet The value entered as CU S VOL is outside the setting range 66603 6505 5 E Specify the volume in an external storage system The number of digits of LDEV S ...

Страница 307: ... 66620 6505 5 E Check the contents of the spreadsheet The number of digits of CU paired VOL is invalid 66621 6505 5 E Check the contents of the spreadsheet The format of CU paired VOL is invalid 66622 6505 5 E Check the contents of the spreadsheet The value entered as CU paired VOL is outside the setting range 66623 6505 5 E Check the contents of the spreadsheet The number of digits of LDEV paired...

Страница 308: ...he spreadsheet The number of digits of ControllerID is invalid 66642 6505 5 E Check the contents of the spreadsheet The format of ControllerID is invalid 66643 6505 5 E Check the contents of the spreadsheet The value entered as ControllerID is outside the setting range 66644 6505 5 E Check the contents of the spreadsheet The number of digits of PathGroup is invalid 66645 6505 5 E Check the content...

Страница 309: ... Check the contents of the spreadsheet The number of digits of DeleteMode is invalid 66663 6505 5 E Check the contents of the spreadsheet The format of DeleteMode is invalid 66664 6505 5 E Check the contents of the spreadsheet The value entered as DeleteMode is outside the setting range 66665 6505 5 E Check the contents of the spreadsheet The number of digits of S VOLWrite is invalid 66666 6505 5 ...

Страница 310: ...of the spreadsheet The value of CopyMode is not supported 66683 6505 5 E Check the contents of the spreadsheet When the pair was operated S VOL was set for VOLType but Disable was not set for S VOLWrite 66684 6505 5 E Check the contents of the spreadsheet When the pair was operated Volume was set for Range but Flush was not set for SuspendMode 66685 6505 0 W Check whether the specified journal gro...

Страница 311: ...ing volume The operation failed because the specified volume was an XP Thin Provisioning volume 68013 6505 0 W Check whether the specified volume is a pool volume of XP Thin Provisioning The operation failed because the specified volume was a pool volume of XP Thin Provisioning 68014 6505 0 W Check whether the specified primary data volume is an XP Thin Provisioning volume The operation failed bec...

Страница 312: ...saster Recovery Extended function was not installed in the secondary storage system 68026 6505 0 W Confirm the LDKC number of the specified extended consistency group Journal groups cannot be added to the extended consistency group EXCTG because the current microcode version does not support LDKC numbers other than 0 68028 6505 0 W Check the contents of the spreadsheet The status of the specified ...

Страница 313: ...cess Manager pair and retry the operation or specify a volume that is not used by XP Continuous Access or XP External Storage Access Manager The Paircreate operation failed because the specified primary data volume was used by XP Continuous Access or XP External Storage Access Manager 68783 6505 0 W The master journal group of the specified primary data volume runs on the 2DC configuration in whic...

Страница 314: ...cess Manager cooperates Release the pair of XP Continuous Access or XP External Storage Access Manager and then retry the operation The pair cannot be released because the specified volume is used as the pair volume of XP Continuous Access or XP External Storage Access Manager 68815 6505 0 W Retry the operation after the completion of discarding zero data on the specified volume The operation fail...

Страница 315: ... failed because the specified journal group was shared with multiple primary and secondary storage systems 68853 6505 0 W Confirm whether a remote command device is assigned to the specified mirror The operation failed because a remote command device has already been assigned to the specified mirror 68857 6505 0 W Confirm the status of the specified mirror The operation failed because the specifie...

Страница 316: ... of FlashCopy Mirroring V2 and the pair status of TrueCopy for Mainframe The operation failed because the specified primary data volume was as follows This volume was used as T VOL of FlashCopy Mirroring V2 This volume was used as M VOL of TrueCopy for Mainframe and it was suspended by either of the following settings It was a pair of synchronous consistency group It was a pair that the Cylinder w...

Страница 317: ...s not a journal group for the 3DC configuration of three XP Continuous Access Journal sites 68908 6505 5 W Verify the specified restore journal group The operation failed because a restore journal group specified for the second mirror was used as a restore journal group of the first mirror 68909 6505 5 W Verify the specified restore journal group A pair cannot be created because the specified rest...

Страница 318: ...the specified secondary data volume was used by another mirror of the journal group and the status of a pair in the mirror was PAIR or in transition COPY Suspending Deleting HOLDING 68915 6505 5 W Verify the status of specified primary data volume The operation failed because the specified primary data volume was in one of the following statuses The consistency CT group of the specified data volum...

Страница 319: ...us Access It is a volume that combined with Copy on Write Snapshot It is a volume that combined with XP Auto LUN 68917 6505 5 W Verify the master journal group The operation to create a pair of the second mirror failed because the specified master journal group was not a journal group for the 3DC configuration of three XP Continuous Access Journal sites 68918 6505 5 W Verify the status of mirror b...

Страница 320: ...riate 68926 6505 Table 55 Error Codes Part Code 6507 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 5 E Check the settings and retry the operation Two or more commands which were not able to be processed were demanded 5036 6507 3 E If the problem persists despite retrying call HP technical support An error occurred during SVP processing If this problem persist...

Страница 321: ...ecify the correct LUN 5143 6510 0 W Check the values and then specify correct values Some of the entered values are incorrect Check the values and then specify correct values 5144 6510 2 E Call HP technical support An error occurred in client logic 7301 6510 2 E Call HP technical support An error occurred in client logic 7302 6510 2 E Call HP technical support An error occurred in client logic 730...

Страница 322: ... To cancel the operation click OK Do you want to cancel 9101 6510 0 i To apply settings in Preview to the disk storage system click OK Do you want to apply 9102 6510 0 i To switch the mode click OK Otherwise click Cancel Do you want to change the mode 9104 6510 0 i To discard the current settings and exit the window click OK Otherwise click Cancel The value that is under setup is not reflected yet...

Страница 323: ...ancel Data has been changed and the graph has been displayed If you continue this operation all the data and the graph will become invalid Are you sure you want to continue this operation 9121 6510 0 i To export the pair status click OK Otherwise click Cancel Are you sure you want to export pair status 9122 6510 0 i To close the graphs click OK Otherwise click Cancel Are you sure you want to close...

Страница 324: ...mber of mirrors in the journal group Then delete unused mirrors or register them in another journal group Too many mirrors in the journal group 55037 6510 0 i Check the number of mirrors in the journal group and then delete unused mirrors Too many mirrors in the subsystem 55038 6510 0 i Check the range setting If you specify Group select only one data volume pair in the mirror You are specifying G...

Страница 325: ...ble Create unused consistency groups and then retry the operation There are no consistency groups available Create unused consistency groups and then retry the operation 56522 6510 0 i Check the mirrors of the specified volume No more mirrors can be created for the specified volume 56523 6510 0 i Check the error information An error occurred Check the error details 59004 6510 0 i Specify the valid...

Страница 326: ...e monitoring switch If necessary use the Performance Monitor Export Tool to export the monitoring data file The monitoring data saved at present will be deleted 59030 6510 5 i To continue processing click OK To stop processing click Cancel The monitoring data currently saved will be deleted when you change the setting of the monitoring switch If necessary use the Export Tool to save the monitoring...

Страница 327: ...specified data volume Change the journal group number if you are performing an Add Pair Paircreate operation Delete the data volume from the Preview set list if you are performing a Resume Pair Pairresync operation The master journal group number for the specified data volume exceeds 0x0F 59108 6510 5 W Check the CLPR number for the specified data volume and specify only one CLPR number There are ...

Страница 328: ...journal volume cannot be deleted because the status of the mirror of the journal group is Active 59153 6510 0 W Check the entered parameter The entered parameter is invalid The serial number the controller ID or the journal group to be added is not specified 59323 6510 0 W Check the status of the specified master journal group A pair which is ready for Delta resync cannot be created under the curr...

Страница 329: ... Specify another volume The specified volume is not valid for this program product Specify another volume 65664 6510 0 W Check the monitoring setting The specified volume is not the volume to be monitored Check the monitoring setting 65665 6510 0 W The microcode versions between the DKCMAIN and the SVP might not match Confirm the microcode versions of the DKCMAIN and the SVP The current microcode ...

Страница 330: ...e operation cannot be completed because the data volume of the same LDEV number is selected multiple times or the specified LDEV is already registered in the preview list 65809 6510 5 W Verify the specified data volume and its journal group The operation cannot be completed for the primary data volume of the Master Restore journal group 65810 6510 5 W Verify the journal groups and the mirror IDs o...

Страница 331: ...not be used by the storage partition administrator 56524 6605 Table 58 Error Codes Part Code 6610 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 0 W Specify the data that you want to register in the SVP and retry the operation The displayed information has not been changed 5030 6610 0 W Check the contents and retry The Operation value is invalid Specify the co...

Страница 332: ...not completed Do you want to continue for other ports 9021 6610 5 W Ensure that the associated channel paths are offline Are you sure you want to exchange the specified ports Confirm the associated channel paths are off line 9024 6610 5 W Remove remote copy paths that are associated with the ports Are you sure you want to switch the ports If the remote copy paths exist on the ports delete them bef...

Страница 333: ... click Cancel Do you want to continue this operation 91 12 6610 0 W To clear SIMs click Yes Otherwise click No Are you sure you want to clear SIMs of XP Continuous Access Journal and Universal Replicator for Mainframe 91 13 6610 0 i Click OK The monitoring was stopped by another operator The graph will be closed 91 15 6610 0 i Click OK Another operator has changed the Gathering Interval value The ...

Страница 334: ...the added paths the duplicated paths will be eliminated Click OK to continue You set the same path more than once The duplicate paths are excluded 9308 6610 0 W Because all the added paths are redundant the paths cannot be added Click OK and continue All paths which you set have already been registered This operation will terminate because there is no path which can be added 9309 6610 0 i Click Re...

Страница 335: ...mber 55208 6610 0 W Specify normal deletion or specify Group as the range You want to forcibly delete pairs but there are some pairs where Group is not specified as the range Specify Group as the range when you want to forcibly delete pairs 55229 6610 0 W To delete pairs click Yes Otherwise click No Warning There are some pairs where Group is not specified as the range in the pairs specified to be...

Страница 336: ... maximum the excess data were discarded No more Preview data can be stored 59009 6610 0 W Check the contents of the primary and secondary volumes If the contents match click Yes Otherwise click No WARNING Initial copy mode None is selected for some volume pair Are you sure that the primary data volume and the secondary data volume of the pair are already synchronized 59010 6610 0 i To output the f...

Страница 337: ...ame volume is included in the journal volumes to be deleted Note the following points if you have made volume pairs by using this journal group before The mainframe volume will be blocked The mainframe volume needs to be formatted when you use the volume as a non journal volume The LDKC number the CU number and the LDEV number of the mainframe volumes are recommended to be recorded Do you want to ...

Страница 338: ... from the Preview list if you are performing a Resume Pair Pairresync operation The master journal group number for the specified data volume exceeds 0x0F 59108 6610 5 W Check the CLPR number for the specified data volume and specify only one CLPR number There are two or more CLPR numbers for the specified data volume In this operation specify only one CLPR number 591 1 1 6610 5 W Specify only the...

Страница 339: ...rocode version of DKCMAIN does not support Add Pair Paircreate operations Resume Pair operations and Change Pair Option operations using the emulation type of the specified volume 59150 6610 0 W To use a mainframe volume as a journal volume call HP technical support and update the microcode version of DKCMAIN The current microprogram version of DKCMAIN only supports OPEN V as the emulation type of...

Страница 340: ...rrent status of the specified master journal group Check the status of the specified master journal group 59327 6610 0 W Change the status of the mirror of the journal group to Initial and then retry the operation The journal volume cannot be deleted because the attribute of the mirror for the journal group is master and the status of the mirror is Hold or Holding 59328 6610 0 W Click the check bo...

Страница 341: ...ommand devices can be assigned to the specified mirror 65778 6610 0 W Check whether the specified journal groups include mirrors available to assign a remote command device There are no mirrors available to assign a remote command device 65779 6610 0 W Specify different mirror IDs in the mirror 1 and the mirror 2 parameters The same mirror ID is specified in the mirror 1 and the mirror 2 parameter...

Страница 342: ...ng call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6012 6805 3 W If this problem persists call HP technical support The SVP is busy Please wait for a while and then retry the operation 6023 6805 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technica...

Страница 343: ...tting is incorrect 5521 1 6805 5 W Correct the setting and then retry If the same problem persists despite retrying call HP technical support The options Block Option and Donot Block Volume Level cannot be specified at the same time 55212 6805 5 W Correct the setting and then retry If the same problem persists despite retrying call HP technical support The Level 1 Threshold setting is incorrect 55...

Страница 344: ...em persists call HP technical support An error occurred during processing If this problem persists call HP technical support 7440 6810 0 i To cancel the operation click OK Do you want to cancel 9101 6810 0 i To execute the operation in Preview click OK Do you want to apply 9102 6810 0 i To change the mode click OK To not change the mode click Cancel The value that is under setup is not reflected y...

Страница 345: ...sage Error Number Part Code 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5013 7005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5099 7005 0 E Call HP technical support An internal logic error occurr...

Страница 346: ...age again reboot the computer If necessary Call HP technical support A time out error occurred 8100 7005 0 i Add shared memory or confirm whether the necessary program product key is installed Sufficient amount of shared memory is not installed or the program product is not installed 8500 7005 5 W Wait a few seconds and retry the operation The command has been rejected because the previous command...

Страница 347: ...ed to the pairs in a PSUS status 8508 7005 0 i Check the contents and retry The Split command with the QUIESCE specification was issued to a secondary boot device 8509 7005 0 i Check the contents and retry The M VOL Suspend command was issued to a secondary boot device 8510 7005 0 i Detach the S VOL from the host or delete the XP Continuous Access path You cannot reserve the volume because a path ...

Страница 348: ... The emulation type of the P VOL is not supported 8522 7005 0 i Specify the emulation type supported in HOMRCF The emulation type of the S VOL is not supported 8523 7005 0 i Specify the emulation type supported in HOMRCF The emulation type is not supported 8524 7005 0 E Call HP technical support An internal logic error occurred 8525 7005 0 E Call HP technical support An internal logic error occurr...

Страница 349: ...chnical support The cache capacities do not match 8537 7005 0 E Call HP technical support An SM failure was detected 8538 7005 0 E There is insufficient shared memory in DKC Call HP technical support There is insufficient shared memory to create 4096 pairs 8539 7005 0 E Call HP technical support There is sufficient shared memory to create 4096 pairs but initial subsystem setup is required before c...

Страница 350: ...pecify another volume The command has been rejected because the specified S VOL is blocked or used as a system disk 8554 7005 0 i Wait until the volume is formatted and retry the operation The S VOL is being formatted 8555 7005 0 i Specify a volume that is not used as a command device as an S VOL This volume cannot be specified as an S VOL because it is used as a command device 8556 7005 0 i You c...

Страница 351: ...fferential table or pair table to set pairs is insufficient 8569 7005 0 i Refresh the window and retry the operation The selected volume does not exist 8570 7005 0 i Check the status of the volume The volume is already defined as a reserved volume 8571 7005 0 i Check the status of the volume The volume is already defined as a P VOL 8572 7005 0 i Release the XP Auto LUN setting The volume is define...

Страница 352: ...tem is invalid 8586 7005 0 i Check the contents and retry The number of pairs that can be set in the same group is invalid 8587 7005 0 i Check the contents and retry The specified group number is not set 8588 7005 0 i Check the contents and retry The specified group name is invalid 8589 7005 0 i Check the contents and retry The group name and the number do not match 8590 7005 0 i Check the content...

Страница 353: ...s an S VOL of the other pair cannot be used as a P VOL The command has been rejected because the specified P VOL has already been used as an S VOL of the other pair 8602 7005 0 i Check the pair status The Pairresync command was issued to a device in the SMPL status 8605 7005 5 W When the P VOL of L1 pair is used as P VOL of XP Continuous Access pair or XP External Storage Access Manager pair L2 pa...

Страница 354: ...relation between the state of XP Continuous Access pair or XP External Storage Access Manager pair and the XP Business Copy operations The command has been rejected because the specified S VOL is used as P VOL of XP Continuous Access pair or XP External Storage Access Manager pair 8614 7005 5 W The S VOL of XP Continuous Access pair or XP External Storage Access Manager pair cannot be used as S VO...

Страница 355: ... Wait until the L2 pair status changes to PSUS and then retry the operation The operation of the L1 pair failed because the L2 pair was in COPY SP status or PSUS SP status 8628 7005 0 i Check the contents and retry The status mode specification is invalid 8629 7005 0 i Check the contents and retry The status mode type is invalid 8630 7005 0 i Call HP technical support The specified CU number is in...

Страница 356: ...P20000 Business Copy Software User s Guide for the relationship between the status of pairs and XP Business Copy operations The command has been rejected because the specified S VOL is shared as the P VOL of the other pair and the pair is in the COPY RS R status 8642 7005 5 W The Pairresync operation cannot be executed in the current pair status See the Creating Pairs and Resynchronize Pair Operat...

Страница 357: ...3 7005 0 i Check the target volume number Boot device and S VOL do not match in Paircreate Pairresync or Pairsplit S instructions 8654 7005 0 i Check the contents and retry An invalid secondary SSID is specified for the Paircreate or Pairresync command 8655 7005 0 i Check the contents and retry The secondary SSID specified for the pairsplit S or pairsplit command is invalid 8656 7005 5 E Call HP t...

Страница 358: ...upport An error occurred during SVP processing If this problem persists call HP technical support 56301 7005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 56302 7005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP techni...

Страница 359: ...e XP Continuous Access pair or execute the operation by other pairs The Quick Restore command has been rejected because the specified pair contains internal and external volumes and also is used as a XP Continuous Access pair 58259 7005 5 W The requested command cannot be executed in the current status of XP Continuous Access pair or XP External Storage Access Manager pair See the section about sh...

Страница 360: ...he specified pair contains internal and external volumes and also is used as a XP Continuous Access Journal pair 58351 7005 0 i Release the pair of XP Continuous Access Journal pair of XP Continuous Access or pair of XP External Storage Access Manager and then retry the operation The command has been rejected because the specified volume was used by XP Continuous Access Journal and XP Continuous A...

Страница 361: ...en retry the operation The PCB required for this operation is not mounted Check the subsystem configuration 58493 7005 2 E Replace the microcode and then retry the operation The operation failed because different versions of microprograms coexisted in the storage system 58520 7005 2 W Release the journal volume setting or specify another volume The operation failed because the specified P VOL was ...

Страница 362: ...Data Retention Utility Retry the operation after the shredding is completed 58579 7005 5 W The specified command cannot be executed with the current pair composition See the Interoperability with Other Products and Functions and XP Business Copy sections described in the HP StorageWorks XP24000 XP20000 Snapshot User s Guide for the relationship when sharing the volumes between XP Snapshot and XP B...

Страница 363: ... was used by Delta resync of XP Continuous Access Journal 58632 7005 0 W Refresh the XP Business Copy window and check the MU number that can be used The operation failed because the specified MU number was already used Specify other MU numbers 5871 1 7005 5 i Specify XP Thin Provisioning volume TP VOL to P VOL when you specify TP VOL to S VOL A pair cannot be created because the volume specified ...

Страница 364: ...are User s Guide for the relationship between the state of XP Continuous Access Asynchronous pair and the XP Business Copy operations The command has been rejected because the specified P VOL is used as an S VOL of XP Continuous Access Asynchronous pair 68749 7005 0 i Quick Restore cannot be executed by the current pair configuration The Quick Restore command was rejected because the specified pai...

Страница 365: ...ity is being added 68810 7005 0 i Delete the XP Continuous Access pair XP Continuous Access Journal pair or XP External Storage Access Manager pair that is using XP Thin Provisioning Volumes and then retry the operation The Initialize function cannot be executed because a XP Continuous Access pair a XP Continuous Access Journal pair or an XP External Storage Access Manager pair is created by using...

Страница 366: ...rt An error occurred during SVP processing If this problem persists call HP technical support 6012 7007 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 71 1 1 7007 Table 63 Error Codes Part Code 7010 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 0 W Check the cap...

Страница 367: ... You cannot create L1 pair for the specified P VOL Delete the created L1 pair and retry the operation The number of L1 pairs exceeds the maximum 6504 7010 0 i You cannot create L2 pair for the specified P VOL Delete the created L2 pair and retry the operation The number of L2 pairs exceeds the maximum 6505 7010 0 E Call HP technical support Unregistered error code 7310 7010 0 W Wait a few seconds ...

Страница 368: ...essing click OK Otherwise click Cancel Do you want to execute the Initialize operation 91 10 7010 0 W Check the device emulation and the definition of the SCSI path There are no valid volumes 9303 7010 0 i Check the selected S VOLs The selected S VOLs include a volume or volumes that is are paired 55003 7010 0 i Correct the number of selected P VOLs and S VOLs The number of selected P VOLs doesn t...

Страница 369: ...rror occurred during SVP processing If this problem persists call HP technical support 5099 7105 0 E Call HP technical support An internal logic error occurred 5625 7105 0 i Release the write protection by Volume Retention Manager The specified volume cannot be used because it is write protected by Volume Retention Manager 5626 7105 0 W Wait a few seconds and retry the operation Processing in prog...

Страница 370: ...atus of the pair 8504 7105 5 E See the Adding Pairs and Pair Status sections in the Hitachi ShadowImage for Mainframe User s Guide HP XP24000 Disk Array HP XP20000 Disk Array for the relationship between the status of pairs and the commands that can be accepted The command has been rejected because the operation cannot be accepted in the current pair status 8505 7105 0 i Check the contents and ret...

Страница 371: ...exceeds the maximum 8517 7105 0 i Check the emulation type You cannot create a pair because the track format is different for each Make sure that the specified emulation type is the same for both 8518 7105 0 i Check the volume capacity You cannot set a pair because the number of cylinders is different for each Make sure that the capacity is the same for both 8519 7105 0 i Specify the volume with t...

Страница 372: ...y HP XP20000 Disk Array for the relationship between the status of Universal Replicator for Mainframe pair and the ShadowImage for Mainframe operations The command has been rejected because the emulation type of the specified volume is not supported or the specified T VOL is used as a data volume of Universal Replicator for Mainframe 8533 7105 0 E Call HP technical support A processor failure was ...

Страница 373: ...ify another volume The command has been rejected because the specified S VOL is blocked or used as a system disk 8550 7105 0 i Wait until the volume is formatted and retry the operation The S VOL is being formatted 8551 7105 0 i As the S VOL specify a volume that is not used as a command device This volume cannot be specified as an S VOL because it is used as a command device 8552 7105 0 i You can...

Страница 374: ...id 8565 7105 0 E Check the contents and retry The attribute of the reserved volume is invalid 8566 7105 0 E Call HP technical support The number of effective lists is invalid 8567 7105 0 i Specify the volume of the supported emulation type The emulation type is invalid 8568 7105 5 W See the Calculating Maximum Number of Pairs section in the Hitachi ShadowImage for Mainframe User s Guide HP XP24000...

Страница 375: ... of the target volume is being changed 8582 7105 0 i Specify the volume of the supported RAID level The RAID level of the specified volume is not supported 8583 7105 0 i Define the reserve volume and then retry the operation No volume is defined as a reserved volume 8584 7105 0 i Stop the operation of the Reserve volume setting or delete the Reserve volume The number of reserved volumes exceeds th...

Страница 376: ... is not an S VOL 8598 7105 0 i Specify other P VOL and retry the operation Or delete the pair of the specified volume and then retry the operation The specified volume is already an S VOL 8599 7105 0 i Check the RAID level and specify a volume of the supported RAID level and then retry the operation The RAID level of the specified volume is not supported 8600 7105 0 i Check the contents and retry ...

Страница 377: ...OL 861 1 7105 0 i Check the status of the volume The specified volume is not a T VOL 8612 7105 0 i Specify a volume of the supported RAID level The RAID level of the specified T VOL is not supported 8613 7105 5 W The requested command cannot be executed in the current status of TrueCopy for Mainframe pair See the Interoperability with Other Products and Functions section in the Hitachi ShadowImage...

Страница 378: ...o Split The Pairresync operation has been rejected because pair status is SP Pend 8627 7105 0 i Select other pairs The operation of the L1 pair failed because the L2 pair was in F COPY status 8628 7105 0 i Check the contents and retry The status mode specification is invalid 8629 7105 0 i Check the contents and retry The status mode type is invalid 8630 7105 0 i Call HP technical support The speci...

Страница 379: ...rent pair status See the Adding Pairs and Resynchronize Pair Operations sections in the Hitachi ShadowImage for Mainframe User s Guide HP XP24000 Disk Array HP XP20000 Disk Array for the relationship between the state of pairs and the ShadowImage for Mainframe operations The Resynchronize Volume Pair operation has been rejected because the specified pair is not in the state of Split 8643 7105 0 i ...

Страница 380: ...valid secondary SSID is specified for the Delete Pair or Split Pair command 8656 7105 5 E Call HP technical support The Swap Freeze option cannot be specified because mode 80 is on 8657 7105 0 i Release the relationship to delete the FlashCopy Mirroring V2 pair or specify another volume The command has been rejected because the specified S VOL is being used as the T VOL of a FlashCopy Mirroring V2...

Страница 381: ...command has been rejected because sufficient amount of shared memory is not installed 8992 7105 0 E Set the shared memory extension setting for FlashCopy Mirroring V2 The command has been rejected because the shared memory is not set for FlashCopy Mirroring V2 8993 7105 0 W Wait a few seconds and retry the operation The command has been rejected because the storage system is busy 8994 7105 0 W Wit...

Страница 382: ...or adding the L2 pair has been rejected because the L1 pair is in V Split status 58001 7105 0 i Quick restore operation cannot be performed when the pair is composed of a normal volume and a customized volume CV Select a different pair The Quick Restore command has been rejected because the specified pair is composed of a normal volume and a customized volume CV 58002 7105 0 i To continue the oper...

Страница 383: ...relationship between the state of TrueCopy for Mainframe pair and the ShadowImage for Mainframe operations The command has been rejected because the specified S VOL is used as a R VOL of TrueCopy for Mainframe pair 58261 7105 0 E Add sufficient shared memory to create a pair A pair cannot be created because shared memory for differential tables is insufficient 58262 7105 5 W Check the requirements...

Страница 384: ...r s existed 58519 7105 2 E Replace the microcode and then retry the operation The operation failed because different versions of microcodes coexisted in the storage system 58520 7105 2 W Release the journal volume setting or specify another volume The operation failed because the specified S VOL was a journal volume 58533 7105 2 W Release the journal volume setting or specify another volume The op...

Страница 385: ...frame pair for Delta resync cannot be specified as an S VOL Specify another volume The operation failed because the specified T VOL was used by Delta resync of Universal Replicator for Mainframe 58631 7105 5 W The P VOL of Universal Replicator for Mainframe pair for Delta resync cannot be specified as a reserved volume Specify another volume The reserve volume setting failed because the specified ...

Страница 386: ...Mainframe pair 68749 7105 0 i The XP Business Copy Operation for FICON R Data Migration cannot be executed in the current pair configuration Specify FICON R Data Migration source volume for S VOL and specify volumes other than FICON R Data Migration source volume for T VOL The XP Business Copy Operation for FICON R Data Migration failed because the specified pair consisted of an S VOL other than a...

Страница 387: ... R Data Migration failed because the T VOL of the specified pair was used by TrueCopy for Mainframe 68773 7105 0 i XP External Storage volume cannot be used as a T VOL Specify another volume The XP Business Copy Operation for FICON R Data Migration failed because the T VOL of the specified pair was used by External Storage 68774 7105 0 i The specified operation cannot be executed in the current pa...

Страница 388: ...e for Mainframe where the specified CTG is in use The command has been rejected because the specified CTG is used by ShadowImage for Mainframe 68833 7105 0 i Use another CTG or release the pair of XP Business Copy where the specified CTG is in use The command has been rejected because the specified CTG is used by Business Copy 68834 7105 0 i Specify the volume not used as S VOL of XP Business Copy...

Страница 389: ...ot be applied 731 1 71 10 0 E Call HP technical support The password could not be acquired 7312 71 10 0 E Call HP technical support Error details not available 7313 71 10 2 E If this problem persists call HP technical support An error occurred during processing If this problem persists call HP technical support 7440 71 10 4 E Retry the operation If you get the same message again reboot the compute...

Страница 390: ...umes that is are paired 55003 71 10 0 i Correct the number of selected S VOLs and T VOLs The number of selected S VOLs doesn t match the number of selected T VOLs Correct the number of selected S VOLs and T VOLs 55004 71 10 5 W Check the values and then enter correct values The entered values are incorrect Check the values and then enter correct values 55597 71 10 5 E Refresh the window and then r...

Страница 391: ... in the Preview List to 16 384 or less 66560 71 10 5 i Change the status of the excluded pair Some pairs are excluded from the pairs to be set because pairs in invalid status for Split Pair are included in the specified pairs 69025 71 10 Table 66 Error Codes Part Code 8005 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 2 E If this problem persists call HP tech...

Страница 392: ...urred during SVP processing If this problem persists call HP technical support 6023 8005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6036 8005 6 E Call HP technical support An error occurred while connecting to the subsystem Wait for a while and then retry the operation 6040 8005 2 E If this probl...

Страница 393: ... the CLPRs and the total of all Cache Residency Manager capacity in the subsystem are not equal 55243 8005 6 E Check the settings and then retry the operation The Cache Residency Manager size set for the CLPR exceeds the maximum available Cache Residency Manager size CLPR No s 55244 8005 6 E Check the settings and then retry the operation The number of Cache Residency Manager areas set for the CLP...

Страница 394: ...age partition administrator 56524 8005 3 E To continue the operation contact the storage administrator and have the settings across the multiple SLPRs cancelled and then retry the operation To perform other operations select a function button Because the settings across the multiple SLPRs are contained the authority has been shifted to the storage administrator from the storage partition administr...

Страница 395: ...nnot change the system disk option due to one of the following reasons The system disk capacity is insufficient The system disk is blocked Confirm the setting status of the current system disk option 65783 8005 3 E Contact the application program distributor A parity group to which 17 or more VDEVs are allocated exists The application program you are using may not support this microprogram version...

Страница 396: ...ingle port group or LUN combination 1004 8105 6 E Check the settings and then retry the operation The following volumes cannot be specified when you change the path configurations Volumes that do not exist Volumes other than the top LUs in expanded LUs Volumes reserved by Auto LUN System Disk volume 1005 8105 6 E Check the setting Failed to remove the path The specified path is the last path of th...

Страница 397: ...105 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again LU path is set to the releasing expanded LU You need to release the expanded LU and path at the same time 1015 8105 2 E The specified port does not exist You have specified a wrong port number Or the specified port type exclusively for mainframe cannot be...

Страница 398: ...all HP technical support 1029 8105 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again The following volumes cannot be specified when you change expanded LU configurations Volumes reserved by Auto LUN 1050 8105 2 E You are trying to perform LUN Security operation for non Fibre port The error does not occur nor...

Страница 399: ...as been already changed Check the settings and request the setting of the configuration information again You are trying to register the same host group as the existing one 1067 8105 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again The specified host group has not been registered 1068 8105 6 E Command devic...

Страница 400: ... 8105 2 E The setting method of command device command device security is incorrect The following settings are invalid 1 Set command device Release command device security 2 Release command device Set command device security The error does not occur normally because it cannot be modified in the window In the unlikely event that this error occurs contact HP technical support An error occurred If th...

Страница 401: ...e name 1 130 8105 6 E The configuration information has been already changed Check the settings and request the setting of the configuration information again Failed to set the host group because the number of host groups exceeds the maximum that can be set in a port 1 131 8105 6 E The configuration information has been already changed Check the settings and request the setting of the configuratio...

Страница 402: ...ray subsystem 1 137 8105 6 W Release the Port Group setting Nothing is set Create a setting and then execute it 1 140 8105 6 E Connect settings and then retry The volume cannot be configured as a command device because the volume does not have Read Write attribute 1 170 8105 6 E Correct the specified contents and request again The specified path cannot be added because the volume is used by a XP C...

Страница 403: ...try the operation The high speed or initiator external mix mode cannot be set to the specified port because of the attribute of the port 1351 8105 6 E Because the port you are trying to set is for XP Continuous Access you must delete the logical path and then retry the port setting Logical paths remain on the Fibre MCU port This operation may cause a fatal damage to the logical paths Please stop t...

Страница 404: ...ied host mode option can be set only for a specific port attribute 1369 8105 6 E Install the necessary program product When an SLPR is allocated install a necessary program product for the SLPR This functionality is not available LUN Manager is required 1600 8105 6 E Install the necessary program product When an SLPR is allocated install a necessary program product for the SLPR This functionality ...

Страница 405: ...ormal status and then retry If the same problem persists despite retrying call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 2003 8105 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 2005 8105 2 E If this problem persists call HP techni...

Страница 406: ...rming I O operations 2097 8105 6 E Delete or suspend all pairs to which the journal volumes belong Devices to be maintained include journal volumes Delete or suspend all pairs to which the journal volumes belong 2204 8105 6 E Delete all pairs to which the journal volumes belong Devices to be maintained include journal volumes Delete all pairs to which the journal volumes belong 2205 8105 5 W Relea...

Страница 407: ...pair and then retry the operation If a reserve volume is defined cancel the reservation If the Quick Split mode is on suspend the pair and then split 2518 8105 6 E Cancel the reserve volume and then retry the operation A Business Copy or ShadowImage for Mainframe reserve volume is defined Cancel the reserve volume and then retry the operation 2519 8105 6 E Cancel the pair definition and then retry...

Страница 408: ...m persists call HP technical support 5566 8105 5 W One line can have up to 127 letters The length of the letter string is invalid 5650 8105 5 W The spreadsheet can have up to 70 000 lines The number of lines is invalid 5651 8105 5 W Check the CSV file The size of the CSV file is invalid 5652 8105 6 E Associate the XP Thin Provisioning volume with a pool and then retry the operation The XP Thin Pro...

Страница 409: ... be turned on because this is not command device 5744 8105 0 W Turn on the security switch on this port The security switch on the port is off Turn on the switch 5745 8105 0 W Correct the group ID The group ID is invalid 5746 8105 0 W Correct the name of the group The group cannot be added Change the name of the group 5747 8105 0 W Correct the group ID The group ID does not exist 5748 8105 0 W Cor...

Страница 410: ...Set the port attribute to target in advance The port cannot be changed because the port is an initiator port 5770 8105 0 W The PCB mode value is invalid Specify a correct value The setting cannot be performed because an invalid PCB mode is set to the specified CHA 5771 8105 0 W Correct the CU and LDEV The system LU cannot be used 5785 8105 0 W Correct the name of port The path can be defined only ...

Страница 411: ...on tag and the DKC serial number The DKC serial number does not match 65639 8105 5 E Check the spreadsheet and make only one description of the SerialNumber function tag Two or more spreadsheet declaration statements and function tags cannot be entered in the spreadsheet file 66003 8105 5 E Check the spreadsheet and enter a serial number under the SerialNumber function tag The spreadsheet declarat...

Страница 412: ...nd retry the operation The file name should be from 1 to 32 characters 5627 81 10 1 E Correct the specified contents and retry the operation Following characters cannot be used for the file name and space 5628 81 10 1 E Correct the specified contents and retry the operation The file specified by File Name on Client does not exist 5629 81 10 1 E Correct the specified contents and retry the operatio...

Страница 413: ...0 5 W Click OK to log off after installation Re start your management session after Java Web Start installation 9339 81 10 0 W To continue processing click OK Otherwise click Cancel Do you want to install Java Web Start 9359 81 10 0 i To overwrite the file click OK Otherwise click Cancel Do you want to overwrite the existing file 59036 81 10 Table 70 Error Codes Part Code 81 1 1 Failure Level Seve...

Страница 414: ...ists call HP technical support An error occurred during processing If this problem persists call HP technical support 7440 8210 Table 72 Error Codes Part Code 8305 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 3 E Select another window To set this function contact the storage administrator This function cannot be used by the storage partition administrator 56...

Страница 415: ...al support An error occurred during SVP processing If this problem persists call HP technical support 2007 8505 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 5099 8505 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP tech...

Страница 416: ...No and then retry the operation If this problem persists call HP technical support An invalid CLPR No was detected 55009 8505 5 E Correct the SLPR No and then retry the operation If this problem persists call HP technical support An invalid SLPR No was detected 55010 8505 5 E Correct the CLPR Name and then retry the operation If this problem persists call HP technical support An invalid CLPR Name ...

Страница 417: ... 8505 5 E Assign a different SSID and then retry the operation If this problem persists call HP technical support The same SSID is already registered in a different SLPR 55020 8505 5 E Specify the correct CU number and then retry the operation If this problem persists call HP technical support The specified CU number is invalid 55021 8505 5 E Correct the CLPR settings and then retry the operation ...

Страница 418: ...is already registered in a different SLPR 55033 8505 5 E Install the program product This function is not available Disk Cache Partition is required to create SLPR or CLPR 55228 8505 4 E Contact the storage administrator To the storage administrator Reconfigure the login information If this problem persists call HP technical support The login information for the partition management function has b...

Страница 419: ...e cache memory of the storage system may be blocked or the storage system is being maintained Check the status of the storage system If this problem persists call HP technical support 5831 1 8505 5 i Wait until the write pending rate falls and then retry the operation The configuration cannot be changed because the write pending rate of the intended CLPR is too high Wait until the write pending ra...

Страница 420: ...all the pair volumes in CT group are contained 58323 8505 5 i Specify the parity groups that do not contain any journal volumes of XP Continuous Access Journal and Universal Replicator for Mainframe or specify the parity groups that contain all the journal volumes in the journal group The CLPR which the parity groups belong to cannot be changed because the specified parity groups do not include al...

Страница 421: ...8510 0 W Change the settings The value set for the number of Cache Residency Manager areas is outside the valid range The value will return to the one set before 55236 8510 0 E Change the SLPR name The SLPR name already exists The SLPR name will return to the name that is displayed before you have changed 55237 8510 0 E Check the settings and retry the operation Some of the selected ports cannot m...

Страница 422: ...ct the No button 57001 8510 0 W Check the settings The maximum number of SSIDs that can be registered will be registered except the duplicate SSIDs 59067 8510 0 i Notice from Partition Definition Check the settings Any statements of the following are displayed in s Installation of XP Disk Cache Partition is required to create more than four SLPRs or CLPRs Additional Cache Memory is required for CL...

Страница 423: ...echnical support 6022 8605 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 7060 8605 6 E Confirm the email address or the server address where the error occurred remove the invalid characters and then retry the registration Invalid character is included in the e mail addresses or the server addresses ...

Страница 424: ...address is left blank When the mail notification service is enabled sender s e mail address is required to input 65759 8610 5 W Enter a destination email address The field of destination e mail address is left blank When the mail notification service is enabled destination e mail address is required to input 65760 8610 5 W Enter the IP address or the host name The IP address of the mail server is ...

Страница 425: ...echnical support An error occurred during SVP processing If this problem persists call HP technical support 5099 9005 6 E Install the program product This functionality is not available Parallel Access Volume is required 5201 9005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6001 9005 2 E If this p...

Страница 426: ...ists call HP technical support 71 16 9005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 71 17 9005 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 7310 9005 3 E Retry the operation If you get the same m...

Страница 427: ... If the same problem persists despite retrying call HP technical support An error occurred during processing If this problem persists call HP technical support 7440 9010 0 W Check the device emulation type or the definition of the journal volume There are no valid volumes 9303 9010 0 W If you want to apply the setting click Yes If not click No In the environment where the host is connected the per...

Страница 428: ...unted LDEV and retry the operation The target LDEV is not mounted 5606 9105 0 W Click OK correct the LDEV group settings and retry the operation The settings of the LDEV group are invalid 5607 9105 0 W Click OK check the attributes of the specified volumes and retry the operation The pool group cannot include volumes to which LU paths are defined or volumes which are not mounted 5608 9105 0 W 1 Cl...

Страница 429: ...ort The configuration could not be changed 81 10 9105 0 E Install PCBs for mainframe computers and then retry the operation No PCBs are installed for mainframe computers 8659 9105 0 W Release the journal volume setting or delete the target volume from the LDEV group The specified LDEV is a journal volume and therefore cannot be registered in LDEV groups 55548 9105 3 E Select another window To set ...

Страница 430: ...e settings You cannot define any more groups 5610 91 10 0 W Click OK and then register another name The specified name has already been used 561 1 91 10 0 W Click OK check the entered characters and register the name again The specified name includes some invalid characters 5612 91 10 0 W Click OK check the registered hosts and retry the operation The specified host is included in another group 56...

Страница 431: ...e registering a host that is already registered in another host group Also you are registering the host in a host group to which ports have already been set 5817 91 10 0 W Check the settings and then retry Ports cannot be set because a host registered in the specified host group is included in another host group 5818 91 10 0 E Call HP technical support An error occurred If this problem persists ca...

Страница 432: ...EV group because the volume configuration has been changed Delete all LDEV groups and register LDEV groups and Security groups again 56538 91 10 0 W Specify other names The specified name has already been used by other LDKC 65648 91 10 5 W To continue processing click OK Otherwise click Cancel The data has been changed The settings will be discarded if you continue the processing Do you want to sw...

Страница 433: ...ring SVP processing If this problem persists call HP technical support 6533 9205 2 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 7060 9205 3 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 71 1 1 9205 5 E I...

Страница 434: ...ts of the Volume Retention Manager spreadsheet The version number entered in the spreadsheet is incorrect 66000 9205 5 E Check the contents of the Volume Retention Manager spreadsheet The function name entered in the spreadsheet is incorrect The function name is not VR 66001 9205 5 E Check the contents of the Volume Retention Manager spreadsheet The process mode written in the spreadsheet cannot b...

Страница 435: ...te set in the Attribute of the spreadsheet is incorrect an attribute other than Read Write Read Only or Protect is entered 66013 9205 5 E Check the logical volume configuration and then retry the operation This logical volume cannot be selected because it is used as a volume for System Disk 68002 9205 Table 86 Error Codes Part Code 9210 Failure Level Severity Level Recommended Action Error Message...

Страница 436: ...rt The mistake is found in the set parameter 6038 9605 5 W Wait a few minutes and then retry the operation Processing in progress Wait for a while and then retry the operation 6502 9605 3 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 6533 9605 2 E If this problem persists call HP technical support An ...

Страница 437: ...port To change the attribute You cannot change the attribute of this logical volume to Read Write Call HP technical support if you want to change the attribute 8134 9605 5 E Check the logical volume configuration and then retry the operation This logical volume is already used as an S VOL for XP Continuous Access or Business Copy 8135 9605 5 E The currently licensed capacity is insufficient To inc...

Страница 438: ...e and then change the access attribute You cannot change the access attribute because the expiration lock is set to Enable 8156 9605 3 E To continue the operation contact the storage administrator and have the settings across the multiple SLPRs cancelled and then retry the operation To perform other operations select a function button Because the settings across the multiple SLPRs are contained th...

Страница 439: ...nt logical volume VMA cannot be set for the specified logical volume because the specified logical volume is a LUSE volume 58420 9605 5 E If this problem persists call HP technical support An error occurred during SVP processing If this problem persists call HP technical support 58422 9605 5 E If this problem persists call HP technical support An error occurred during SVP processing If this proble...

Страница 440: ...en changed 58436 9605 5 E Select a logical volume without VMA VMA is set to the logical volume 58437 9605 5 E Check the logical volume configuration and then retry the operation This logical volume is configured as a command device 58438 9605 5 E Select a logical volume whose emulation type is OPEN V The emulation type of the logical volume is not OPEN V 58442 9605 5 E Specify an open system volum...

Страница 441: ...ccurred during SVP processing If this problem persists call HP technical support 58450 9605 5 E Check the logical volume configuration and then retry the operation This logical volume cannot be selected because it is used as a volume for System Disk 68002 9605 Table 88 Error Codes Part Code 9610 Failure Level Severity Level Recommended Action Error Message Error Number Part Code 2 E If this proble...

Страница 442: ...ng and retry the operation 55640 10010 5 W Reply to the message The current setting is not applied Apply the setting and then retry the operation 55641 10010 5 i Reply to the message The path to the output folder is invalid The first character of the path to the output folder shall be 55642 10010 5 i To transfer the Audit Log to the FTP server click OK Otherwise click Cancel Do you want to transfe...

Страница 443: ... Level Recommended Action Error Message Error Number Part Code 5 W Specify a valid password The length of the character string of the specified password is invalid 65720 101 10 5 W Specify the file name Specify the file name 65725 101 10 Remote Web Console Error Codes 443 ...

Страница 444: ...es 1 PB petabyte 1 0005 bytes HP XP storage systems use the following values to calculate logical storage capacity values logical devices 1 KB kilobyte 1 024 bytes 1 MB megabyte 1 0242 bytes 1 GB gigabyte 1 0243 bytes 1 TB terabyte 1 0244 bytes 1 PB petabyte 1 0245 bytes 1 block 512 bytes HP Technical Support For worldwide technical support information see the HP support website http www hp com su...

Страница 445: ...sites For additional information see the following HP websites http www hp com http www hp com go storage http www hp com support manuals http www hp com storage spock Documentation Feedback HP welcomes your feedback To make comments and suggestions about product documentation send a message to storagedocsFeedback hp com All submissions become the property of HP HP Websites 445 ...

Страница 446: ...ring FICON R Fibre connectivity G GID Group ID L L1 L2 Level 1 level 2 LBA Logical block address LCP Local control port LD LDEV Logical device An LDEV is created when a RAID group is carved into pieces according to the selected host emulation mode that is OPEN 3 OPEN 8 OPEN 9 The number of resulting LDEVs depends on the selected emulation mode The term LDEV is also known as term volume LDKC Logica...

Страница 447: ...agement Protocol A widely used network monitoring and control protocol Data is passed from SNMP agents which are hardware and or software processes reporting activity in each network device hub router bridge and so on to the workstation console used to oversee the network The agents return information contained in a MIB Management Information Base which is a data structure that defines what is obt...

Страница 448: ...V V VOL Virtual volume VDEV Virtual device VLL Virtual LVI LUN VMA Volume management area W WWN World wide name 448 Glossary ...

Отзывы: