Table 54 Error Codes — Part Code 6505
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
0
W
Specify a volume that is not
used by FICON(R) Data
Migration.
The specified volume cannot
be used as a journal volume
because it is used by
FICON(R) Data Migration.
68811
6505
0
W
Check each capacity of the
primary data volume and the
secondary data volume after
the capacity change of
secondary data volume ends.
Plan a combination of
volumes for pair creating.
A pair could not be created
because the specified
secondary data volume was
an XP Thin Provisioning
volume whose capacity was
being changed.
68812
6505
0
W
Check each capacity of the
primary data volume and the
secondary data volume after
the capacity change of
primary data volume ends.
Plan a combination of
volumes for pair creating.
A pair could not be created
because the specified
primary data volume was an
XP Thin Provisioning volume
whose capacity was being
changed.
68813
6505
0
W
The specified volume runs on
the 2DC configuration in
which XP Continuous Access
or XP External Storage
Access Manager cooperates.
Release the pair of XP
Continuous Access or XP
External Storage Access
Manager, and then retry the
operation.
The pair cannot be released
because the specified volume
is used as the pair volume of
XP Continuous Access or XP
External Storage Access
Manager.
68815
6505
0
W
Retry the operation after the
completion of discarding
zero data on the specified
volume.
The operation failed, because
the specified secondary data
volume was a volume of XP
Thin Provisioning whose zero
data was being discarded.
68842
6505
0
W
Retry the operation after the
completion of discarding
zero data on the specified
volume.
The operation failed, because
the specified primary data
volume was a volume of XP
Thin Provisioning whose zero
data was being discarded.
68843
6505
0
W
Wait until the initializing
process is completed, and
then retry the operation.
The operation failed, because
the specified primary data
volume was being initialized
by Business Copy or
ShadowImage for
Mainframe.
68848
6505
0
W
Wait until the initializing
process is completed, and
then retry the operation.
The operation failed, because
the specified secondary data
volume was being initialized
by Business Copy or
ShadowImage for
Mainframe.
68849
6505
314
Remote Web Console for Storage System Messages and Error Codes