Table 50 Error Codes — Part Code 6005
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
0
W
Refresh the window, and
confirm the pair status of the
specified volume.
The operation failed. The
operation cannot be
accepted in the pair status of
the specified volume.
68796
6005
0
W
Check each capacity of the
M-VOL and the R-VOL after
the capacity change of R-VOL
ends, and plan a
combination of volumes for
pair creating.
A pair could not be created
because the specified R-VOL
was an XP Thin Provisioning
volume whose capacity was
being changed.
68812
6005
0
W
Check each capacity of the
M-VOL and the R-VOL after
the capacity change of
M-VOL ends, and plan a
combination of volumes for
pair creating.
A pair could not be created
because the specified M-VOL
was an XP Thin Provisioning
volume whose capacity was
being changed.
68813
6005
0
W
The specified volume is a
primary data volume of XP
Continuous Access Journal,
which runs on the 2DC
configuration in which XP
Continuous Access or XP
External Storage Access
Manager cooperates. Specify
another volume.
A pair cannot be created
because the specified volume
is used as a primary data
volume of the XP Continuous
Access Journal.
68816
6005
0
W
The RCU runs on the 2DC
configuration in which the XP
Continuous Access Journal
cooperates.
Set Track to the Difference
Management, and then retry
the operation.
The specified R-VOL was a
pair volume of the XP
Continuous Access Journal.
A pair could not be created
because “Cylinder” was set
to the “Difference
Management”.
68817
6005
0
W
Install XP External Storage,
and then retry the operation.
The operation failed, because
the External Storage function
was not installed.
68826
6005
250 Remote Web Console for Storage System Messages and Error Codes