Table 50 Error Codes — Part Code 6005
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
2
E
If this problem persists, call
HP technical support.
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
6012
6005
3
W
If the same problem persists
despite retrying, call HP
technical support.
The SVP is busy. Please wait
for a while, and then retry the
operation.
6023
6005
4
E
Retry the operation. If you get
the same message again,
reboot the computer. If
necessary, call HP technical
support.
A time-out error occurred.
8000
6005
4
E
Retry the operation. If you get
the same message again,
reboot the computer. If
necessary, call HP technical
support.
A time-out error occurred.
8001
6005
4
E
Retry the operation. If you get
the same message again,
reboot the computer. If
necessary, call HP technical
support.
A time-out error occurred.
8100
6005
0
W
Wait for awhile, refresh the
window, and confirm the pair
status has been changed
properly.
If the pair status is not
changed after refreshing the
window, check the MCU or
RCU configuration and the
and the condition of the paths
between the MCU and RCU.
The storage system accepted
the request normally,
however the processing
requires some time. Wait for
awhile, and then refresh the
window and confirm the pair
status has been changed
properly.
If the pair status is not
changed after refreshing the
window, check the MCU or
RCU and the condition of the
paths between the MCU and
RCU.
8104
6005
4
i
Retry the operation.
Retry operation.
8700
6005
4
i
A logical path does not exist
between the MCU and the
RCU. Check the path status
on RCU Status dialog box,
and reestablish the paths with
Edit Path.
Logical Path between the
MCU and the RCU is not
active.
8701
6005
4
i
Refresh the window, and
check whether the specified
volume is a M-VOL.
The specified volume is not
an M-VOL.
8702
6005
4
i
The number of paths is less
than the minimum number
specified on the RCU Option
dialog box. Check the
number of paths, establish the
minimum number of paths,
and retry the operation.
The specified number of Paths
is less than the Minimum
number of Paths on RCU
Option screen.
8703
6005
Remote Web Console Error Codes