Table 67 Error Codes — Part Code 8105
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
6
E
The configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
High Speed mode/MIX mode
was specified. However,
there are addresses to which
High Speed mode/MIX mode
cannot be set in the Fibre
Addresses of the specified
ports.
1203
8105
6
E
The configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
High Speed mode/MIX mode
was specified. However,
there are topologies to which
High Speed mode/MIX mode
cannot be set in the
topologies of the specified
ports.
1204
8105
6
E
The port you are trying to set
is for XP Continuous Access.
You must change the attribute
(Target or RCU Target) when
adding a path.
Add path to the initiator port
failed.
1350
8105
6
E
Cannot set to high-speed
mode because the port
attributes are mixed, or
cannot set to
internal/external mix mode
because the combination of
port attributes is different.
Check the port attributes, and
then retry the operation.
The high-speed or
initiator/external mix mode
cannot be set to the specified
port because of the attribute
of the port.
1351
8105
6
E
Because the port you are
trying to set is for XP
Continuous Access, you must
delete the logical path, and
then retry the port setting.
Logical paths remain on the
Fibre-MCU port. This
operation may cause a fatal
damage to the logical paths.
Please stop this operation. If
you want to continue this
operation, please remove the
logical paths from the MCU
port first.
1352
8105
6
E
Because the port you are
trying to set is for XP
Continuous Access, you must
delete the S-VOL logical path
that is set to RCU Target, and
then retry the port setting.
S-VOLs remain on the
Fibre-RCU port. This
operation may cause a fatal
damage to S-VOLs. Please
stop this operation. If you
want to continue this
operation, please remove the
S-VOLs from the RCU port
first.
1353
8105
6
E
The port you are trying to set
is for XP Continuous Access.
You must change the attribute
(Target or RCU Target) when
adding a WWN.
Failed to add the WWN to
the initiator port.
1354
8105
6
E
The port you are trying to set
is for XP Continuous Access.
You must change the attribute
(Target or RCU Target) when
adding a WWN.
The host mode of the host
group connected to the
Initiator port cannot be
changed.
1355
8105
Remote Web Console Error Codes 403