Table 45 Error Codes — Part Code 5205
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
6
E
Retry the same operation
several times. If the same
error occurs, call HP technical
support.
There is insufficient Auto LUN
data to create migration
plans. Check the following:
•
The time setting for the
sampling term
•
The monitoring term
7420
5205
6
E
If the same problem persists
despite retrying, call HP
technical support.
A proper migration plan
cannot be made by this
function. Check the following
items.
•
Reserve volume location.
•
The maximum threshold
value of the class.
7421
5205
6
E
Retry the same operation
several times. If the same
error occurs, call HP technical
support.
A memory allocation error
occurred.
7422
5205
6
E
Retry the same operation
several times. If the same
error occurs, call HP technical
support.
An internal error occurred.
7423
5205
6
E
Retry the same operation
several times. If the same
error occurs, call HP technical
support.
Failed to delete all plans.
7424
5205
6
E
Retry the same operation
several times. If the same
error occurs, call HP technical
support.
Failed to delete plan.
7426
5205
6
E
Retry the same operation
several times. If the same
error occurs, call HP technical
support.
An error occurred while
connecting to the subsystem.
Wait for a while, and then
retry the operation.
8001
5205
2
E
If this problem persists, call
HP technical support.
The storage system status is
invalid. Call HP technical
support.
8002
5205
6
E
This function is not supported.
8100
5205
6
E
Retry the same operation
several times. If the same
error occurs, call HP technical
support.
This function is not supported.
8102
5205
0
E
Check the volume, or quit
using XP Continuous Access.
An internal logic error
occurred.
8525
5205
0
E
Check the volume, or quit
using XP Continuous Access.
An internal logic error
occurred.
8526
5205
0
E
Check the volume, or quit
using XP Continuous Access.
An internal logic error
occurred.
8528
5205
0
E
Check the volume, or quit
using XP Continuous Access.
An internal logic error
occurred.
8529
5205
Remote Web Console Error Codes 201