14
Environmental and technical specifications
Environmental and technical specifications
There are specific environmental and technical specifications for each hardare platform. The
specifications help you when planning the appropriate installation location, environmental conditions, and
resources, such as power and cooling.
Enclosure size and weights
OmniCube servers have specific size dimensions and weights. This information helps you when planning
to install the enclosure in a rack.
Dimension
Centimeters
Inches
Enclosure width
48.2
17.5
Maximum height
8.73
3.44
Maximum depth (from rack
flange)
75.58
29.75
The maximum weight of a system with all storage drives installed is 30.4 kg, or 67.02 lbs.
Power and thermal
OmniCube servers have two redundant power supplies with specific power and thermal specifications.
Table 5: OmniCube Power and Thermal Specifications
Specification
Description
Current consumption
10A-5A
Supply voltage
100–240V AC (autoranging). Make sure each
power source has sufficient electrical overload
protection.
Frequency
50/60Hz
Heat dissipation
4100 BTU/hr max
Maximum inrush current
55A
Energy efficiency
Energy Star, spec version 1.0
Power supply efficiency
90-96% efficient (load dependent)
Temperature and humidity