Environmental and technical specifications
15
Specification
Description
Humidity and
Temperature
(continuous operation)
10°C to 35°C (50°F to 95°F) at 10% to 80% relative humidity with 26°C
(78.8°F) maximum dew point (maximum wet bulb temperature). De-rate
maximum allowable dry bulb temperature at 1°C per 300m above 950m
(1°F per 547 ft above 3117 ft).
Temperature (storage) -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation
of 20°C per hour.
Vibration and shock
OmniCube servers have limits for vibration and shock under operating and storage conditions.
Specification Description
Vibration
(operating)
0.26Grms at 5-350Hz in all orientations.
Vibration
(storage)
1.88Grms at 10-500Hz for 15 minutes (all six sides tested).
Shock
(operating)
Six consecutively executed shock pulses in the positive and negative x, y, and z
axes of 40 G for up to 2.3 ms.
Shock
(storage)
Six consecutively executed shock pulses in the positive and negative x, y, and z
axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Altitude and airborne contaminants
OmniCube servers have limits for altitude and airborne contaminants under operating and storage
conditions.
Specification
Description
Altitude (operating)
-15.2m to 3048m (–50 ft to 10,000 ft)
Altitude (storage)
-15.2m to 12,000m (–50 ft to 39,370 ft)
Contaminant level (operating)
Class G1 or lower as defined by ISA-
S71.04-1985
Agency compliance standards
OmniCube servers meet agency compliance standards.
An OmniCube host complies with the following standards:
• CNS14436-1, CNS13438
• UL 60950-1, 2nd Edition, 2011-12-19; CSA C22.2 No. 60950-1-07, 2nd Edition
• EK1-ITB 2000:2014
• EMC EMCA41269-EM i EMCA41269-IM od 14.07.2014