Specifications 137
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating 10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping -40
°
C to 70
°
C (-40
°
F to 158
°
F)
Maximum wet bulb temperature 28
°
C (82.4
°
F)
Relative humidity
(noncondensing)**
Operating 10%
to
90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Server specifications
Specification Value
Dimensions
Rack model
—
Height
17.48 cm (6.88 in)
Depth
69.93 cm (27.53 in)
Width
48.34 cm (19.03 in)
Tower model
—
Height
47.04 cm (18.52 in)
Depth
73.96 cm (29.12 in)
Width
24.77 cm (9.75 in)
Weight
Weight (when lightly loaded) —
Rack
25.00 kg (55.12 lbs)
Tower
30.00 kg (66.14 lbs)
Weight (maximum)
46.75 kg (103.06 lbs)
Содержание ProLiant DL370
Страница 1: ...HP ProLiant DL ML370 G6 Server User Guide Part Number 513482 001 March 2009 First Edition ...
Страница 16: ...Component identification 16 SFF hard drives LFF hard drives ...
Страница 29: ...Operations 29 6 Remove the hard drive cage blank ...
Страница 83: ...Hardware options installation 83 o Rear 1 o Front 2 17 Remove the chassis from the tower side panels ...
Страница 94: ...Cabling 94 Drive cage bay 2 Drive cage bay 3 ...
Страница 95: ...Cabling 95 Six bay LFF backplane cabling Drive cage bay 1 Drive cage bay 2 ...
Страница 97: ...Cabling 97 Battery cabling for BBWC DVD ROM drive cabling ...
Страница 98: ...Cabling 98 Slimline optical drive cabling ...
Страница 123: ...Troubleshooting 123 ...
Страница 146: ...Technical support 146 ...
Страница 147: ...Technical support 147 ...