Server software and configuration utilities 87
configuration process. This automated server configuration process cuts time from each server deployed,
making it possible to scale server deployments to high volumes in a rapid manner.
For more information, and to download the SmartStart Scripting Toolkit, refer to the HP website
(
http://www.hp.com/servers/sstoolkit
).
HP ROM-Based Setup Utility
RBSU, an embedded configuration utility, performs a wide range of configuration activities that may
include:
•
Configuring system devices and installed options
•
Displaying system information
•
Selecting the primary boot controller
•
Configuring memory options
•
Language selection
For more information on RBSU, refer to the
HP ROM-Based Setup Utility User Guide
on the Documentation
CD or the HP website (
http://www.hp.com/servers/smartstart
).
Boot options
After the auto-configuration process completes, or after the server reboots upon exit from RBSU, the POST
sequence runs, and then the boot option screen is displayed. This screen is visible for several seconds
before the system attempts to boot from a diskette, CD, or hard drive. During this time, the menu on the
screen allows you to install an operating system or make changes to the server configuration in RBSU.
BIOS Serial Console
BIOS Serial Console allows you to configure the serial port to view POST error messages and run RBSU
remotely through a serial connection to the server COM port. The server that you are remotely configuring
does not require a keyboard and mouse.
For more information about BIOS Serial Console, refer to the
BIOS Serial Console User Guide
on the
Documentation CD or the HP website (
http://www.hp.com/servers/smartstart
).
Configuring memory
After installing the required DIMMs, configure the server memory:
1.
To power up the server, press the Power On/Standby button.
2.
Access RBSU by pressing the
F9
key during powerup when prompted.
3.
Select
System Options.
4.
Select
Advanced Memory Protection.
5.
Select the appropriate mode:
•
Advanced ECC
•
Online spare
•
Mirrored memory
•
Hot-plug RAID memory
6.
Press the
Enter
key.
7.
Press the
Escape
key
twice to return to the RBSU menu.
8.
Press the
F10
key to exit RBSU.
Содержание ML570 - ProLiant - G2
Страница 1: ...HP ProLiant ML570 Generation 3 Server User Guide February 2006 Fourth Edition Part Number 374178 004 ...
Страница 26: ...Server component identification 26 Status Green Operating normally Amber Failed Off No power ...
Страница 68: ...Hardware options installation 68 7 Remove the memory board and place on a flat surface ...
Страница 85: ...Server cabling 85 IMPORTANT Install the RILOE II board into slot 3 or 4 for ease of cabling ...
Страница 103: ...Troubleshooting 103 ...
Страница 127: ...Acronyms and abbreviations 127 WOL Wake on LAN ...