background image

 

Troubleshooting  114 

Item 

See 

13 

 

"Server information you need" in the 

HP ProLiant Servers 

Troubleshooting Guide

 located on the Documentation CD or see 

"Troubleshooting resources (on page 

102

)" 

 

"Operating system information you need" in the 

HP ProLiant Servers 

Troubleshooting Guide

 located on the Documentation CD or see 

"Troubleshooting resources (on page 

102

)" 

 

 

 

 

 

Содержание ML350 - ProLiant - G2

Страница 1: ... the person who installs administers and troubleshoots servers and storage systems HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels Part Number 513503 004 April 2012 Edition 4 ...

Страница 2: ...xpress warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Microsoft and Windows are U S registered trademarks of Microsoft Corporation Bluetooth is a trademark owned by its proprietor and used by Hewlett Packard Company under lice...

Страница 3: ... the server rear panel rack model 25 Open or remove the tower bezel 25 Remove the access panel 26 Install the access panel 27 Remove the media bay blank 27 Remove the large redundant fan air baffle 27 Remove the DIMM baffle 28 Remove a fan blank 29 Setup 30 Optional installation services 30 Optimum environment 30 Space and airflow requirements 30 Temperature requirements 31 Power requirements 32 E...

Страница 4: ...plug power supply option 68 Expansion board options 69 Removing the expansion slot cover 70 Installing an expansion board 71 PCI X expansion cage option 72 Battery backed write cache option 78 FBWC module and capacitor pack option 80 150W PCIe video graphics controller power cable option 82 HP Trusted Platform Module option 85 Installing the Trusted Platform Module board 85 Retaining the recovery ...

Страница 5: ... boot problems flowchart 115 Server fault indications flowchart 116 POST error messages and beep codes 118 Battery replacement 120 Regulatory compliance notices 121 Regulatory compliance identification numbers 121 Federal Communications Commission notice 121 FCC rating label 121 FCC Notice Class A Equipment 121 FCC Notice Class B Equipment 121 Declaration of conformity for products marked with the...

Страница 6: ...127 Server specifications 128 Environmental specifications 128 Mechanical specifications 128 Power supply specifications 128 Technical support 131 Before you contact HP 131 HP contact information 131 Customer Self Repair 131 Acronyms and abbreviations 139 Index 142 ...

Страница 7: ...tion 7 Component identification Front panel components Item Description 1 Power On Standby button 2 UID button 3 USB connectors 2 4 Hot plug hard drive bays 8 bay SFF drive cage model 5 Removable media bays 6 Optical drive ...

Страница 8: ...ical state see the system board LEDs on page 13 Off Normal when in standby mode 3 Power cap LED Green Power cap configured Flashing amber Power cap exceeded Off Server in standby or power cap disabled 4 NIC 1 activity LED Green Network link Flashing Network link and activity Off No link to network If power is off view status on the rear panel RJ 45 LEDs Rear panel LEDs and buttons on page 10 5 NIC...

Страница 9: ... x8 4 2 1 9 Slot 3 PCIe2 x8 8 4 2 1 10 Slot 4 PCIe2 x16 8 4 2 1 75W EXT 75W4 11 Slot 5 PCIe2 x8 4 2 1 12 Slot 6 PCIe2 x8 4 2 1 13 RJ 45 Ethernet connector dedicated iLO 2 management 14 Serial connector 15 Mouse connector The SAS expander and the HP NC522SFP Dual Port 10GbE Server Adapter are not supported in slot 1 HP recommends the SAS expander is installed in slot 2 The HP NC522SFP Dual Port 10G...

Страница 10: ...as failed 2 UID LED Blue Activated Flashing blue System managed remotely Off Deactivated 3 Power supply 1 LED Green Power supply is on and functioning Off AC power is not available or AC power supply has failed 4 iLO 2 link LED Green Linked to network Off Not linked to network 5 iLO 2 activity LED Green or flashing Network activity Off No network activity 6 NIC 2 link LED Green Linked to network O...

Страница 11: ...ity System board components Item Description 1 Processor 1 DIMM slots 2 Power supply backplane connector 3 Processor socket 2 4 System fan 4 connector 5 System power connectors 6 Processor 2 DIMM slots 7 System fan 3 connector 8 SD card slot non hot plug 9 System maintenance switch 10 Front panel LED board connector 11 SAS connector B 12 SAS connector A 13 HP Smart Array P410i memory connector ...

Страница 12: ...2 1 23 Internal USB connector 24 Internal USB tape connector 25 System battery 26 System fan 2 connector 27 Processor socket 1 28 System fan 1 connector The SAS expander and the HP NC522SFP Dual Port 10GbE Server Adapter are not supported in slot 1 HP recommends the SAS expander is installed in slot 2 The HP NC522SFP Dual Port 10GbE Server Adapter is only supported in slot 3 4 To support options b...

Страница 13: ...mber Fan is missing or has failed Off Fan is functioning 5 AMP status Green AMP mode is enabled Amber Failover has occurred or the configuration is not valid Off AMP mode is disabled 6 Processor 2 DIMMs Amber An error has occurred Off Normal operation 7 System fan 3 Amber Fan is missing or has failed Off Fan is functioning 8 Overtemperature Amber System temperature threshold exceeded Off Normal op...

Страница 14: ...ore a hard reset To force the OS to invoke the NMI handler and generate a crash dump log the administrator can use the iLO Virtual NMI feature For more information see the white paper on the HP website http h20000 www2 hp com bc docs support SupportManual c00797875 c00797875 pdf System maintenance switch Position Default Function S1 Off Off iLO 2 security is enabled On iLO 2 security is disabled S...

Страница 15: ...Component identification 15 SAS SATA device numbers SFF configuration with an optional SAS expander SFF configuration with a second SAS controller ...

Страница 16: ...Component identification 16 LFF configuration SAS and SATA hard drive LEDs Item Description 1 Fault UID LED amber blue 2 Online LED green ...

Страница 17: ...n or stripe migration but a predictive failure alert has been received for this drive To minimize the risk of data loss do not replace the drive until the expansion or migration is complete Flashing regularly 1 Hz Off Do not remove the drive Removing a drive may terminate the current operation and cause data loss The drive is rebuilding erasing or it is part of an array that is undergoing capacity...

Страница 18: ...4 Green BBWC Status LED To interpret the illumination patterns of this LED see the following table LED3 pattern LED4 pattern Interpretation Off Flashing 2 Hz The system is powered down and the cache contains data that has not yet been written to the drives Restore system power as soon as possible to prevent data loss Data preservation time is extended any time that 3 3 V auxiliary power is availab...

Страница 19: ...cuit exists across the battery terminals or within the battery pack BBWC features are disabled until the battery pack is replaced The life expectancy of a battery pack is typically more than 3 years Flashing 1 Hz An open circuit exists across the battery terminals or within the battery pack BBWC features are disabled until the battery pack is replaced The life expectancy of a battery pack is typic...

Страница 20: ...terpretation Off Off The flash code is corrupt Fan locations and configurations CAUTION To maintain proper cooling all fan bays must be populated with a fan or a fan blank Fan locations Item Description 1 Rear fan 1 2 Rear fan 2 3 Front fan 3 4 Front fan 4 ...

Страница 21: ...ion 21 Single processor standard fan configuration Item Description 1 Rear fan 1 2 Rear fan 2 3 Front fan 3 4 Processor 1 5 DIMM baffle Single processor redundant fan configuration Item Description 1 Rear fan 1 2 Rear fan 2 ...

Страница 22: ...ption 3 Front fan 3 4 Front fan 4 5 Processor 1 6 DIMM baffle 7 Large redundant fan air baffle Dual processor non redundant fan configuration Item Description 1 Rear fan 1 2 Rear fan 2 3 Front fan 3 4 Processor 1 5 Processor 2 6 DIMM baffles ...

Страница 23: ...t identification 23 Dual processor redundant fan configuration Item Description 1 Rear fan 1 2 Rear fan 2 3 Front fan 3 4 Front fan 4 5 Processor 1 6 Processor 2 7 DIMM baffles 8 Large redundant fan air baffle ...

Страница 24: ...and rear panels of the server 4 Press the Power On Standby button to place the server in standby mode When the server activates standby power mode the system power LED changes to amber 5 If the server is installed in a rack locate the server by identifying the illuminated rear UID LED button 6 Disconnect the power cords The system is now without power Extend the server from the rack 1 Pull down th...

Страница 25: ...ce Access the server rear panel rack model If the procedure requires accessing the server rear panel unlock the cable management arm and swing the arm away from the server For information on unlocking the cable management arm refer to the installation instructions that ship with the 3 7U Quick Deploy Rail System Open or remove the tower bezel This server has a removable bezel that must be unlocked...

Страница 26: ...ed from the bezel Remove the access panel 1 Release the access panel latch 2 Slide the access panel back about 1 5 cm 0 5 in 3 Lift and remove the access panel CAUTION For proper cooling do not operate the server without the access panel baffles expansion slot covers hard drives or blanks installed ...

Страница 27: ...en or remove the tower bezel on page 25 o Extend the server from the rack on page 24 CAUTION Always populate each media bay with either a device or a blank Proper airflow can only be maintained when the bays are populated Unpopulated drive bays can lead to improper cooling and thermal damage 3 Remove the media bay blank Remove the large redundant fan air baffle 1 Power down the server on page 24 2...

Страница 28: ...one of the following o Open or remove the tower bezel as needed Open or remove the tower bezel on page 25 o Extend the server from the rack on page 24 3 Remove the access panel on page 26 4 Remove the large redundant fan air baffle if installed Remove the large redundant fan air baffle on page 27 5 Remove the DIMM baffle ...

Страница 29: ...Open or remove the tower bezel as needed Open or remove the tower bezel on page 25 o Extend the server from the rack on page 24 3 Remove the access panel on page 26 4 Remove the large redundant fan air baffle if installed Remove the large redundant fan air baffle on page 27 5 Remove the fan blank ...

Страница 30: ... the Care Pack services are Hardware support o 6 Hour Call to Repair o 4 Hour 24x7 Same Day o 4 Hour Same Business Day Software support o Microsoft o Linux o HP ProLiant Essentials HP SIM and RDP o VMWare Integrated hardware and software support o Critical Service o Proactive 24 o Support Plus o Support Plus 24 Startup and implementation services for both hardware and software For more information...

Страница 31: ... provide proper server cooling from flow through perforations in the front and rear doors that provide 64 percent open area for ventilation CAUTION When using a Compaq branded 7000 series rack install the high airflow rack door insert PN 327281 B21 for 42U rack PN 157847 B21 for 22U rack to provide proper front to back airflow and cooling CAUTION If a third party rack is used observe the following...

Страница 32: ...cuit AC current rating Do not use common power outlet strips for this equipment Provide a separate electrical circuit for the server Electrical grounding requirements The server must be grounded properly for proper operation and safety In the United States you must install the equipment in accordance with NFPA 70 1999 Edition National Electric Code Article 250 as well as any local and regional bui...

Страница 33: ...f the rack when it is rolling down the ramp from the pallet Always handle the rack from both sides Contents of the tower server shipping carton Unpack the server shipping carton and locate the materials and documentation necessary for installing the server The contents of the server shipping carton include Server Tower server feet Power cord Keyboard not included in all regions Mouse not included ...

Страница 34: ...ng up a tower server Follow the steps in this section to set up a tower model server If you are going to install the server into a rack refer to the rack installation Installing the server into the rack on page 35 section 1 Install the feet 2 Return the server to an upright position 3 Connect peripheral devices to the server Rear panel components on page 9 WARNING To reduce the risk of electric sh...

Страница 35: ...stabilize the product during installation or removal especially when the product is not fastened to the rails When the server weighs more than 22 5 kg 50 lb at least two people must lift the server into the rack together A third person may be required to help align the server if the server is installed higher than chest level Use caution when installing the server in or removing the server from th...

Страница 36: ...HP ROM Based Setup Utility User Guide located on the Documentation CD Installing the operating system To operate properly the server must have a supported operating system For the latest information on supported operating systems refer to the HP website http www hp com go supportos Two methods are available to install an operating system on the server SmartStart assisted installation Insert the Sm...

Страница 37: ...CAUTION To avoid damage to the processor and system board only authorized personnel should attempt to replace or install the processor in this server CAUTION To help avoid damage to the processor and system board do not install the processor without using the processor installation tool CAUTION To prevent possible server malfunction and damage to the equipment multiprocessor configurations must co...

Страница 38: ...he processor locking lever prevents the processor from seating during installation leading to hardware damage 7 Open the processor locking lever and the processor socket retaining bracket Do not remove the processor socket cover IMPORTANT Be sure the processor remains inside the processor installation tool ...

Страница 39: ...ation 39 8 If the processor has separated from the installation tool carefully re insert the processor in the tool Handle the processor by the edges only and do not touch the bottom of the processor especially the contact area ...

Страница 40: ... ARE VERY FRAGILE AND EASILY DAMAGED CAUTION THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED To avoid damage to the system board Never install or remove a processor without using the processor installation tool Do not touch the processor socket contacts Do not tilt or slide the processor when lowering the processor into the socket ...

Страница 41: ...socket retaining bracket and the processor locking lever The processor socket cover is automatically ejected Remove the cover CAUTION Be sure to close the processor socket retaining bracket before closing the processor locking lever The lever should close without resistance Forcing the lever closed can damage the processor and socket requiring system board replacement ...

Страница 42: ...Hardware options installation 42 1 Open the heatsink locking levers 2 Remove the heatsink protective cover 3 Install the heatsink ...

Страница 43: ...o optimize performance install memory into the processor 2 DIMM slots System board components on page 11 6 Remove the fan blank in fan bay 3 Remove a fan blank on page 29 7 Install the fan into fan bay 3 8 Connect the fan cable to the system board System board components on page 11 ...

Страница 44: ...s to both types When specified as RDIMM or UDIMM the information applies to that type only All memory installed in the server must be the same type The server supports the following DIMM speeds Single and dual rank PC3 10600 DDR 1333 DIMMs operating at 1333 and 1066 MHz Quad rank PC3 8500 DDR 1067 DIMMs operating at 1066 MHz Depending on the processor model the number of DIMMs installed and whethe...

Страница 45: ...Some DIMM configuration requirements are based on these classifications A single rank DIMM has one set of memory chips that is accessed while writing to or reading from the memory A dual rank DIMM is similar to having two single rank DIMMs on the same module with only one rank accessible at a time A quad rank DIMM is effectively two dual rank DIMMs on the same module Only one rank is accessible at...

Страница 46: ...ilability the server supports the following AMP modes Advanced ECC provides the greatest memory capacity for a given DIMM size while providing up to 4 bit error correction This mode is the default option for this server Mirrored Memory provides maximum protection against failed DIMMs Uncorrectable errors in one channel are corrected by the mirror channel Lockstep provides enhanced protection while...

Страница 47: ... configure the Maximum Memory Bus Frequency option in the ROM Based Setup Utility to 1066 MHz If there is one quad rank LVDIMM per channel on any populated memory channel in the system running at 1066 MHz the LVDIMMs operate at 1 5V This setting preserves maximum memory subsystem performance To have DIMMs operate at 1 35V configure the Maximum Memory Bus Frequency option in the ROM Based Setup Uti...

Страница 48: ...y reducing the likelihood of uncorrected memory errors This protection is available without any operating system support Online spare memory protection dedicates one rank of each memory channel for use as spare memory The remaining ranks are available for OS and application use If correctable memory errors occur at a rate higher than a specific threshold on any of the non spare ranks the server au...

Страница 49: ...g order RDIMM Sequentially in alphabetical order A through I UDIMM A through F sequentially in alphabetical order Do not populate DIMM slots G through I Mirrored Memory population guidelines For Mirrored Memory mode configurations observe the following guidelines Observe the general DIMM slot population guidelines on page 48 Always install DIMMs in channels 1 and 2 for each installed processor Do ...

Страница 50: ...ored memory support Configuring mirrored memory on page 93 Lockstep Memory population guidelines For Lockstep memory mode configurations observe the following guidelines Observe the general DIMM slot population guidelines on page 48 Always install DIMMs in channels 1 and 2 for each installed processor Do not install DIMMs in channel 3 for any processor DIMM configuration on channel 1 and channel 2...

Страница 51: ... G H or I After installing the DIMMs use RBSU to configure the system for Lockstep memory support Configuring lockstep memory on page 94 Installing DIMMs CAUTION To avoid damage to the hard drives memory and other system components the air baffle drive blanks and access panel must be installed when the server is powered up 1 Power down the server on page 24 2 Do one of the following o Open or remo...

Страница 52: ...RBSU HP ROM Based Setup Utility on page 92 SAS or SATA hard drive option CAUTION For proper cooling do not operate the server without the access panel baffles expansion slot covers hard drives or blanks installed IMPORTANT When installing a x3 x1 SAS cable in an SFF system HP recommends connecting the x3 part of the x3 x1 cable to the SAS hard drive backplane connector that corresponds to hard dri...

Страница 53: ...Hardware options installation 53 To install the component 1 Remove the hard drive blank 2 Open the release latch to prepare the drive for installation ...

Страница 54: ...t support mixing SFF and LFF optional hard drive expansion cages Installing a hard drive expansion cage power cable 1 Power down the server on page 24 2 Do one of the following o Open or remove the tower bezel as needed Open or remove the tower bezel on page 25 o Extend the server from the rack on page 24 3 Remove the access panel on page 26 4 Disconnect all cables connected to the system board Sy...

Страница 55: ...6 Remove the large redundant fan air baffle if installed Remove the large redundant fan air baffle on page 27 7 Remove the DIMM baffles Remove the DIMM baffle on page 28 8 Disconnect the fan cables and then remove all fans 9 Loosen the two system board thumbscrews ...

Страница 56: ...ble from the option kit to the power supply backplane Be sure to thread the cables through the hole in the center wall 12 Install the system board 13 Tighten the thumbscrews 14 Connect all cables to the system board 15 Install all fans 16 Install all DIMM baffles 17 Install the large redundant fan air baffle if removed 18 Install all expansion boards ...

Страница 57: ... and components in HP ProLiant ML350 G6 Servers For supported options see the QuickSpecs at the HP website http www hp com servers proliantml350 To install the component 1 Install the hard drive expansion cage power cable Installing a hard drive expansion cage power cable on page 54 2 Remove the two bezel blanks closest to the primary hard drive cage 3 Using a T 15 Torx screwdriver remove the slee...

Страница 58: ...ive cage into the server CAUTION Always populate each media bay with either a device or a blank Proper airflow can only be maintained when the bays are populated Unpopulated drive bays can lead to improper cooling and thermal damage 7 Thread the SAS cables through the hole in the center wall 8 Connect the SAS cables to the optional SAS controller or SAS expander board ...

Страница 59: ...into the rack 13 Power up the server on page 24 Two bay LFF drive cage option CAUTION To avoid damage to the pin connectors install only supported hard drive cages and components in HP ProLiant ML350 G6 Servers For supported options see the QuickSpecs at the HP website http www hp com servers proliantml350 To install the component 1 Install the hard drive expansion cage power cable Installing a ha...

Страница 60: ... SAS cable from the connector B labeled 4 and 5 on the primary drive cage backplane Retain the cable for future use IMPORTANT When installing the optional two bay LFF expansion hard drive cage the existing SAS cable B on the primary drive will be replaced by the mini SAS Y cable from the option kit 6 Connect the following cables o The sideband LED cable to the optional hard drive cage ...

Страница 61: ...ve cage bay and then thread the drive cables through the bay 8 Slide the optional hard drive cage about three fourth of the way into the bay leaving room to connect cables at the back of the drive cage 9 Connect the following cables o The power cable to the optional hard drive cage o The sideband LED cable from the optional hard drive cage to the primary hard drive cage ...

Страница 62: ...Proper airflow can only be maintained when the bays are populated Unpopulated drive bays can lead to improper cooling and thermal damage 11 Connect the common end of the mini SAS Y cable to the SAS connector B on the system board 12 Install any hard drives or blanks SAS or SATA hard drive option on page 52 13 Install the access panel on page 27 14 Do one of the following o Close or install the tow...

Страница 63: ...optical drive and the other four bays have blanks You can install two full height devices or up to four additional half height media devices in the removable media cage To install a half height or full height media device 1 Power down the server on page 24 2 Do one of the following o Open or remove the tower bezel as needed Open or remove the tower bezel on page 25 o Extend the server from the rac...

Страница 64: ... shipping screw on page 64 10 Install the access panel on page 27 11 Do one of the following o Close or install the tower bezel as needed o Slide the server back into the rack Installing the full height media device shipping screw When shipping a server with a full height media device installed always install a shipping screw to secure the device 1 Install the full height media device Installing a...

Страница 65: ...Redundant fan assembly option To install the component 1 Power down the server on page 24 2 Do one of the following o Open or remove the tower bezel as needed Open or remove the tower bezel on page 25 o Extend the server from the rack on page 24 3 Remove the access panel on page 26 4 Remove the fan blank from fan bay 4 Remove a fan blank on page 29 ...

Страница 66: ...options installation 66 5 Install the fan in fan bay 4 6 Connect the fan cable to the system board System board components on page 11 7 Align the baffle guide posts with the holes on the fan and the system board ...

Страница 67: ...electrical outlet that is easily accessible at all times Unplug the power cord from the power supply to disconnect power to the equipment Do not route the power cord where it can be walked on or pinched by items placed against it Pay particular attention to the plug electrical outlet and the point where the cord extends from the equipment WARNING To reduce the risk of personal injury from hot surf...

Страница 68: ...s who are qualified in servicing server equipment and trained to deal with products capable of producing hazardous energy levels WARNING To reduce the risk of personal injury from hot surfaces observe the thermal labels on each power supply or module WARNING To reduce the risk of injury from electric shock hazards do not open power supplies Refer all maintenance upgrades and servicing to qualified...

Страница 69: ...se lock lever clicks securing the power supply 4 Connect the power cord to the power supply 5 Using the retaining clip shipped with the server secure the power cord to the power supply handle Securing the cord will ensure enough slack 6 Connect the power cord to the AC power source 7 Be sure that the power supply LED is illuminated green Rear panel LEDs and buttons on page 10 Expansion board optio...

Страница 70: ...wer bezel on page 25 o Extend the server from the rack on page 24 3 Remove the access panel on page 26 4 Push the release latches on the expansion board retainer and then pull the retainer out away from the chassis 5 Remove the expansion slot cover CAUTION To prevent improper cooling and thermal damage do not operate the server unless all PCI slots have either an expansion slot cover or an expansi...

Страница 71: ...wer down the server on page 24 2 Do one of the following o Open or remove the tower bezel as needed Open or remove the tower bezel on page 25 o Extend the server from the rack on page 24 3 Remove the access panel on page 26 4 Remove the expansion slot cover from the slot if installed Removing the expansion slot cover on page 70 IMPORTANT It may be necessary to remove the slot cover next to the slo...

Страница 72: ... monitoring of the riser fans which appear as fans 5 and 6 In addition both expansion boards installed in the PCI X expansion cage appear as slots 1 and 2 To install the component CAUTION To prevent damage to the server or expansion boards power down the server and remove all AC power cords before removing or installing the PCI X expansion cage 1 Power down the server on page 24 2 Do one of the fo...

Страница 73: ...emove the airflow shield from the chassis Retain the shield for future use if the PCI X expansion cage is not installed 6 Remove the four T 15 screws from the hard drive cage and then partially extend the hard drive cage from the chassis ...

Страница 74: ...Hardware options installation 74 7 Pull the spring loaded locking pin out and then turn it one quarter turn to an extended position 8 Remove a PCI X expansion slot cover ...

Страница 75: ...Hardware options installation 75 9 Install PCI X expansion boards in the PCI X expansion cage 10 Install the PCI X expansion cage Secure the assembly with the screws from the rear access panel ...

Страница 76: ... board or the expansion slot cover for expansion slot 1 Removing the expansion slot cover on page 70 The PCI X expansion cage is supported only by slot 1 14 Install the included PCI Express conversion card into expansion slot 1 With the PCI X expansion cage option the additional PCI X slots are recognized as slot 1 by the ROM 15 Close the expansion board retainer ...

Страница 77: ... cables from any installed media bay devices 18 Connect the included power cable extension a Connect the extension to the PCI X expansion cage b Connect the extension to the first power connector of both system power cables 19 Connect the power connectors on the power cable extension to any installed media bay devices Route the unused portion of the system power cables to avoid airflow restriction...

Страница 78: ...or damage to the equipment do not add or remove the battery pack while an array capacity expansion RAID level migration or stripe size migration is in progress IMPORTANT The battery pack might have a low charge when installed In this case a POST error message is displayed when the server is powered up indicating that the battery pack is temporarily disabled No action is necessary on your part The ...

Страница 79: ...ove the tower bezel on page 25 o Extend the server from the rack on page 24 3 Remove the access panel on page 26 4 Locate the cache module connector System board components on page 11 5 Open the cache module latches 6 Install the cache module 7 Connect the cable to the cache module 8 Connect the cable to the battery pack 9 Install the battery pack ...

Страница 80: ...not use this controller with cache modules designed for other controller models because the controller can malfunction and you can lose data Also do not transfer this cache module to an unsupported controller model because you can lose data To install the component 1 Back up all data 2 Close all applications 3 Power down the server on page 24 CAUTION In systems that use external data storage be su...

Страница 81: ...Hardware options installation 81 6 Remove the large redundant air baffle if installed Remove the large redundant fan air baffle on page 27 7 Install the FBWC module 8 Connect the cable ...

Страница 82: ...efore installing a high wattage video graphics controller install the cable For more information see Installing an expansion board on page 71 CAUTION To avoid damage to the pin connectors only use the supported video cable when installing this option For supported options see the QuickSpecs at the HP website http www hp com servers proliantml350 To install the component 1 Power down the server on ...

Страница 83: ... expansion boards 6 Remove the large redundant fan air baffle if installed Remove the large redundant fan air baffle on page 27 7 Remove the DIMM baffles Remove the DIMM baffle on page 28 8 Remove all fans 9 Loosen the two system board thumbscrews ...

Страница 84: ...power supply backplane Be sure to thread the cable through the center wall 12 Install the system board 13 Tighten the thumbscrews 14 Connect all cables to the system board 15 Install all fans 16 Install all DIMM baffles 17 Install the large redundant fan air baffle if removed 18 Install all expansion boards 19 Connect the PCIe power cable to an installed PCIe expansion board as needed ...

Страница 85: ...move the TPM from the system board When requested HP Service provides a TPM with the spare system board Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet Upon locating a broken or disfigured rivet on an installed TPM administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data W...

Страница 86: ...talled TPM administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data 5 Install the TPM board Press down on the connector to seat the board System board components on page 11 6 Install the TPM security rivet by pressing the rivet firmly into the system board 7 Install the access panel on page 27 8 Do one of the following o Close o...

Страница 87: ...press the Enter key to modify the TPM Functionality setting 6 Press the Esc key to exit the current menu or press the F10 key to exit RBSU 7 Reboot the server 8 Enable the TPM in the OS For OS specific instructions see the OS documentation CAUTION When a TPM is installed and enabled on the server data access is locked if you fail to follow the proper procedures for updating the system or option fi...

Страница 88: ...ck server 1 Power down the server on page 24 2 Disconnect all rear panel cabling Rear panel components on page 9 3 Remove the tower bezel Open or remove the tower bezel on page 25 4 Remove the feet 5 Remove both tower configuration panels a Using the T 10 Torx screwdriver remove the front panel screws b Unhook the tower configuration panels from the chassis ...

Страница 89: ...Hardware options installation 89 c Slide them back and away from the chassis ...

Страница 90: ...l on page 26 8 Align the pins on the rack bezel with the corresponding slots on the chassis Secure the rack bezel to the chassis using the screws inside the chassis 9 Install the access panel on page 27 10 Install the server into the rack Installing the server into the rack on page 35 ...

Страница 91: ...artStart Scripting Toolkit The SmartStart Scripting Toolkit is a server deployment product that allows you to build an unattended automated installation for high volume server deployments The SmartStart Scripting Toolkit is designed to support ProLiant BL ML DL and SL servers The toolkit includes a modular set of utilities and important documentation that describes how to apply these tools to buil...

Страница 92: ...s Help for a highlighted configuration option press the F1 key IMPORTANT RBSU automatically saves settings when you press the Enter key The utility does not prompt you for confirmation of settings before you exit the utility To change a selected setting you must select a different setting and press the Enter key Default configuration settings are applied to the server at one of the following times...

Страница 93: ...ot process the boot options screen is displayed This screen is visible for several seconds before the system attempts to boot from a supported boot device During this time you can do the following Access RBSU by pressing the F9 key Access the System Maintenance Menu which enables you to launch ROM based Diagnostics or Inspect by pressing the F10 key Access the boot menu by pressing the F11 key For...

Страница 94: ...chnology memoryprotection html Configuring lockstep memory To configure Lockstep memory 1 Install the required DIMMs Installing DIMMs on page 51 2 Access RBSU by pressing the F9 key during power up when the prompt is displayed 3 Select System Options 4 Select Advanced Memory Protection 5 Select Lockstep with Advanced ECC Support 6 Press the Enter key 7 Press the Esc key to exit the current menu or...

Страница 95: ...first logical drive assign RAID levels and establish online spare configurations The utility also provides support for the following functions Reconfiguring one or more logical drives Viewing the current logical drive configuration Deleting a logical drive configuration Setting the controller to be the boot controller Selecting the boot volume If you do not use the utility ORCA will default to the...

Страница 96: ...to HP ProLiant DL980 Servers or panic A system fail safe timer the ASR timer starts when the System Management driver also known as the Health Driver is loaded When the operating system is functioning properly the system periodically resets the timer However when the operating system fails the timer expires and restarts the server ASR increases server availability by restarting the server within a...

Страница 97: ...actory state deletes the current hardware configuration information including array setup and disk partitioning and erases all connected hard drives completely Refer to the instructions for using this utility Run the Erase Utility if you must erase the system for the following reasons You want to install a new operating system on a server with an existing operating system You encounter an error wh...

Страница 98: ...k and physical access to secure data For additional security you can disable the internal USB connectors through RBSU External USB functionality HP provides external USB support to enable local connection of USB devices for server administration configuration and diagnostic procedures For additional security external USB functionality can be disabled through RBSU Internal SD support An internal SD...

Страница 99: ...artStart provides the memory spare part numbers for the server To download the latest version see the HP website http www hp com support Integrated Management Log The IML records hundreds of events and stores them in an easy to view form The IML timestamps each event with 1 minute granularity You can view recorded events in the IML in several ways including the following From within HP SIM From wi...

Страница 100: ...MPORTANT Always perform a backup before installing or updating device drivers The server includes new hardware that may not have driver support on all OS installation media If you are installing a SmartStart supported OS use the SmartStart software on page 91 and its Assisted Path feature to install the OS and latest driver support If you are installing drivers from the SmartStart CD be sure that ...

Страница 101: ...nd Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products For more information refer to the HP website http www hp com go pcn Care Pack HP Care Pack Services offer upgraded service levels to extend and expand bundled services with easy to buy easy to use support packages that help you make the most of your server inve...

Страница 102: ...support ProLiant_TSG_jp Pre diagnostic steps WARNING To avoid potential problems ALWAYS read the warnings and cautionary information in the server documentation before removing replacing reseating or modifying system components IMPORTANT This guide provides information for multiple servers Some information may not apply to the server you are troubleshooting Refer to the server documentation for in...

Страница 103: ... component exceeds the recommended weight for one individual to handle safely WARNING To reduce the risk of personal injury or damage to the equipment observe local occupational health and safety requirements and guidelines for manual material handling These symbols on power supplies or systems indicate that the equipment is supplied by multiple sources of power WARNING To reduce the risk of injur...

Страница 104: ...tem you must provide at least 7 6 cm 3 0 in of clearance at the front and back of the server CAUTION The server is designed to be electrically grounded earthed To ensure proper operation plug the AC power cord into a properly grounded AC outlet only Symptom information Before troubleshooting a server problem collect the following information What events preceded the failure After which steps does ...

Страница 105: ...n the troubleshooting process Before performing any troubleshooting steps that involve processors review the following guidelines Be sure that only authorized personnel perform the troubleshooting steps that involve installing removing or replacing a processor Always locate the documentation for your processor model before performing any steps that require installing removing or replacing a proces...

Страница 106: ... any processors be sure to follow the guidelines provided in Performing processor procedures in the troubleshooting process on page 105 Failure to follow the recommended guidelines can cause damage to the system board requiring replacement of the system board Loose connections Action Be sure all power cords are securely connected Be sure all cables are properly aligned and securely connected for a...

Страница 107: ...you start with the first flowchart in this section Start diagnosis flowchart on page 107 and follow the appropriate diagnostic path If the other flowcharts do not provide a troubleshooting solution follow the diagnostic steps in General diagnosis flowchart on page 108 The General diagnosis flowchart is a generic troubleshooting process to be used when the problem is not server specific or is not e...

Страница 108: ...nsure of the problem or if the other flowcharts do not fix the problem use the following flowchart Item See 1 Symptom information on page 104 2 Loose connections on page 106 3 Service notifications on page 107 4 The most recent version of a particular server or option firmware is available on the HP Support website http www hp com support ...

Страница 109: ...intenance and service guide located on the Documentation CD or the HP website http www hp com products servers platforms 8 Breaking the server down to the minimum hardware configuration on page 105 or in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see Troubleshooting resources on page 102 9 Server information you need in the HP ProLiant Servers Troubleshooting ...

Страница 110: ...Troubleshooting 110 Server power on problems flowchart Symptoms The server does not power on The system power LED is off or amber ...

Страница 111: ...rver maintenance and service guide located on the Documentation CD or the HP website http www hp com products servers platforms 5 Integrated Management Log on page 99 or in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see Troubleshooting resources on page 102 6 Power source problems in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD...

Страница 112: ...Troubleshooting 112 ...

Страница 113: ... 6 Server health LEDs on page 107 and Component identification on page 7 7 Loose connections on page 106 8 General memory problems are occurring in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see Troubleshooting resources on page 102 9 Server maintenance and service guide located on the Documentation CD or the HP website http www hp com products servers platfor...

Страница 114: ...iant Servers Troubleshooting Guide located on the Documentation CD or see Troubleshooting resources on page 102 Operating system information you need in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see Troubleshooting resources on page 102 ...

Страница 115: ...ted on the Documentation CD or see Troubleshooting resources on page 102 Controller documentation Loose connections on page 106 6 General memory problems are occurring in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see Troubleshooting resources on page 102 7 Operating system problems in the HP ProLiant Servers Troubleshooting Guide located on the Documentation ...

Страница 116: ... boots but a fault event is reported by Insight Management Agents Server boots but the internal health LED external health LED or component health LED is red or amber NOTE For the location of server LEDs and information on their statuses refer to the server documentation ...

Страница 117: ...n problems flowchart Server power on problems flowchart on page 110 6 HP Insight Diagnostics on page 98 or in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see Troubleshooting resources on page 102 7 Hardware problems in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see Troubleshooting resources on page 102 Server maintenance an...

Страница 118: ...rror messages and beep codes For a complete listing of error messages refer to the POST error messages in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website http www hp com support ...

Страница 119: ...Troubleshooting 119 WARNING To avoid potential problems ALWAYS read the warnings and cautionary information in the server documentation before removing replacing reseating or modifying system components ...

Страница 120: ...C 140 F Do not disassemble crush puncture short external contacts or dispose of in fire or water Replace only with the spare designated for this product To remove the component 1 Power down the server on page 24 2 Do one of the following o Open or remove the tower bezel as needed Open or remove the tower bezel on page 25 o Extend the server from the rack on page 24 3 Remove the access panel on pag...

Страница 121: ...s to bear a label indicating the interference potential of the device as well as additional operating instructions for the user FCC rating label The FCC rating label on the device shows the classification A or B of the equipment Class B devices have an FCC logo or ID on the label Class A devices do not have an FCC logo or ID on the label After you determine the class of the device refer to the cor...

Страница 122: ...cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation For questions regarding this product contact us by mail or telephone Hewlett Packard Company P O Box 692000 Mail Stop 530113 Houston Texas 77269 2000 1 800 HP INVENT 1 800 474 6836 For continuous quality improvement calls may be recorded or monitored For ques...

Страница 123: ...vided by HP Compliance with these directives implies conformity to applicable harmonized European standards European Norms that are listed in the EU Declaration of Conformity issued by HP for this product or product family and available in English only either within the product documentation or at the following HP website http www hp eu certificates type the product number in the search field The ...

Страница 124: ...lectrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste dispo...

Страница 125: ...ents or perform procedures to the laser device other than those specified herein Allow only HP Authorized Service technicians to repair the unit The Center for Devices and Radiological Health CDRH of the U S Food and Drug Administration implemented regulations for laser products on August 2 1976 These regulations apply to laser products manufactured from August 1 1976 Compliance is mandatory for p...

Страница 126: ...ring or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales giveaway or promotion Contact a qualified Taiwanese recycler for proper battery disposal Power cord statement for Japan Acoustics statement for Germany Geräuschemission Schalldruckpegel LpA 70 dB A Zuschauerpositionen bystander positions Normaler Betrieb nor...

Страница 127: ...atic sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance...

Страница 128: ...based on a maximum temperature of 45 C 113 F Altitude maximum for storage corresponds to a pressure minimum of 70 kPa Mechanical specifications Specification Value Dimension Height without tower feet 44 45 cm 17 50 in Height with tower feet 46 70 cm 18 38 in Depth with tower bezel 60 00 cm 23 60 in Width 22 00 cm 8 66 in Weight no drives installed 27 22 kg 60 00 lb Power supply specifications Depe...

Страница 129: ...AC 4 3 A at 200 VAC Rated input power 857 W at 100V AC input 824 W at 200V AC input BTUs per hour 2925 at 100V AC input 2812 at 200V AC input Power supply output Rated steady state power 750 W at 100V to 120V AC input 750 W at 200V to 240V AC input Maximum peak power 750 W at 100V to 120V AC input 750 W at 200V to 240V AC input HP ProLiant 460 W Power Supply Specification Value Input requirements ...

Страница 130: ...Server specifications 130 Maximum peak power 460 W at 100V to 120V AC input 460 W at 200V to 240V AC input ...

Страница 131: ...dentification number Applicable error messages Add on boards or hardware Third party hardware or software Operating system type and revision level HP contact information For United States and worldwide contact information see the Contact HP website http www hp com go assistance In the United States To contact HP by phone call 1 800 334 5144 For continuous quality improvement calls may be recorded ...

Страница 132: ...repair Réparation par le client CSR Les produits HP comportent de nombreuses pièces CSR Customer Self Repair réparation par le client afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses Si pendant la période de diagnostic HP ou ses partenaires ou mainteneurs agréés détermine que la réparation peut être effectuée à l aide d une pièce CSR HP vous l envoie ...

Страница 133: ... di costo solo in alcune zone In caso di necessità si può richiedere l assistenza telefonica di un addetto del centro di supporto tecnico HP Nel materiale fornito con una parte di ricambio CSR HP specifica se il cliente deve restituire dei componenti Qualora sia richiesta la resa ad HP del componente difettoso lo si deve spedire ad HP entro un determinato periodo di tempo generalmente cinque 5 gio...

Страница 134: ...ios de servicio de HP identifica que una reparación puede llevarse a cabo mediante el uso de un componente CSR HP le enviará dicho componente directamente para que realice su sustitución Los componentes CSR se clasifican en dos categorías Obligatorio componentes para los que la reparación por parte del usuario es obligatoria Si solicita a HP que realice la sustitución de estos componentes tendrá q...

Страница 135: ... de geïllustreerde onderdelencatalogus aangemerkt met Nee Afhankelijk van de leverbaarheid en de locatie worden CSR onderdelen verzonden voor levering op de eerstvolgende werkdag Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden indien dit mogelijk is gezien de locatie Indien assistentie gewenst is belt u een HP Service Partner om via de telefoon technische onderst...

Страница 136: ...s pode ser feita mediante uma taxa adicional Se precisar de auxílio entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP Nos casos em que isso for necessário é preciso enviar a peça com defeito à HP dentro do período determinado normalmente c...

Страница 137: ...Technical support 137 ...

Страница 138: ...Technical support 138 ...

Страница 139: ...n Utility ADU Array Diagnostics Utility AMP Advanced Memory Protection ASR Automatic Server Recovery DDR double data rate FBWC flash backed write cache IEC International Electrotechnical Commission iLO Integrated Lights Out IML Integrated Management Log LFF large form factor LV DIMM Low voltage DIMM ...

Страница 140: ...xpress Peripheral Component Interconnect Express PCI X peripheral component interconnect extended PDU power distribution unit POST Power On Self Test PSP ProLiant Support Pack RBSU ROM Based Setup Utility RDIMM Registered Dual In line Memory Module SAS serial attached SCSI SATA serial ATA SFF small form factor SIM Systems Insight Manager ...

Страница 141: ...Acronyms and abbreviations 141 TMRA recommended ambient operating temperature TPM trusted platform module UDIMM Unregistered Dual In Line Memory Module UID unit identification ...

Страница 142: ...nese notice 133 components 7 9 12 configuration of system 37 38 95 Configuration Replication Utility 96 configuration tools 95 configuring AMP modes 98 connectors 7 8 9 12 14 contacting HP 139 140 CSR customer self repair 140 customer self repair CSR 140 D Declaration of Conformity 129 device numbers 16 diagnosing problems 107 diagnostic tools 96 100 101 103 diagnostics utility 103 DIMM installati...

Страница 143: ... 35 39 installing hardware 39 installing operating system 38 Integrated Lights Out iLO 101 Integrated Management Log IML 104 internal health LED 7 8 18 J Japanese notice 132 K Korean notices 132 L laser devices 133 LED health 7 8 112 LED system power 8 LED UID 8 10 LEDs 7 17 18 LEDs front panel 8 LEDs hard drive 17 18 LEDs NIC 7 8 10 14 LEDs rear panel 10 LEDs system board 14 LEDs troubleshooting ...

Страница 144: ...rver features and options 39 service notifications 112 shipping carton contents 35 site requirements 32 SmartStart autorun menu 95 SmartStart Scripting Toolkit 95 SmartStart software 38 SmartStart overview 95 space requirements 32 specifications environmental 136 specifications power 137 specifications server 136 start diagnosis flowchart 113 static electricity 135 support 104 139 support packs 95...

Отзывы: