![HP HPE ProLiant DL365 Gen10 Plus Server Скачать руководство пользователя страница 202](http://html.mh-extra.com/html/hp/hpe-proliant-dl365-gen10-plus-server/hpe-proliant-dl365-gen10-plus-server_user-manual_164424202.webp)
SFF cables
SFF cables
Option kit
Option kit
Cable part number
Cable part number
Connects from
Connects from
Connects to
Connects to
8 SFF x4TMode UBM3
8 SFF x4TMode UBM3
backplane kit (P26429-B21)
backplane kit (P26429-B21)
8 SFF NVMe backplane, MLB, x8
port1a
P20855-001
8 SFF x4 UBM3 backplane ports
1 and 2
Port 1B / Port 2B
8 SFF NVMe backplane, MLB, x8
port1b
P20856-001
8 SFF x4 UBM4 backplane ports
3 and 4
Port 1A / Port 2A
8 SFF x4NVMe UBM4 backplane
8 SFF x4NVMe UBM4 backplane
kit (P26433-B21)
kit (P26433-B21)
8 SFF NVMe backplane, MLB, x8
port1a
P20855-001
8 SFF x4 UBM4 backplane ports
1 and 2
Port 1B / Port 2B
8 SFF NVMe backplane, MLB, x8
port1b
P20856-001
8 SFF x4 UBM4 backplane ports
1 and 2
Port 1B / Port 2B
8 SFF SAS/SATA backplane kit
8 SFF SAS/SATA backplane kit
(P38579-B21)
(P38579-B21)
SAS/SATA 8 SFF backplane,
P408i-a/P816i-a
P20816-001
8 SFF SAS/SATA backplane
Smart Array controllers P408i-
p/E208i-p/P408i-a/P816i-a port
1 or port 2
2 SFF SAS/SATA Backplane kit
2 SFF SAS/SATA Backplane kit
(P38580-B21)
(P38580-B21)
Power cable, 8 SFF to 2 SFF
869667-001
2 SFF backplane
8 SFF backplane
SAS/SATA, 2 SFF backplane,
P816i-a, 10P
P20817-001
2 SFF SAS/SATA backplane
Smart Array controller P816i-a
port 3
SAS/SATA 2 SFF backplane, P/E P26551-001
2 SFF SAS/SATA backplane
SATA port 1, Smart Array
controllers P408i-p/E208i-p
port 1
2 SFF U.3 Backplane Option Kit
2 SFF U.3 Backplane Option Kit
(P38581-B21) / 2 SFF U.2
(P38581-B21) / 2 SFF U.2
Backplane option kit (P38582-
Backplane option kit (P38582-
B21)
B21)
Power cable, 8 SFF to 2 SFF
869667-001
2 SFF backplane
8 SFF backplane
2 SFF U.3 backplane Pri NVMe
P20857-001
2 SFF U.3 backplane
R16 riser port 3A
NVMe, 2 SFF backplane, MLB to
port 8A
P39979-001
2 SFF U.3 backplane
Port 8A, AROC passthrough
board port 7A
8 SFF TMode Cable Kit
8 SFF TMode Cable Kit
(P26451-B21)
(P26451-B21)
8 SFF U.3 backplane, NVMe
P20863-001
8 SFF U.2 / U.3 backplane
HPE Smart Array Controller
SR932i-p port 4i
8 SFF U.3 backplane, NVMe2
P20864-001
8 SFF U.2 / U.3 backplane
HPE Smart Array Controller
SR932i-p port 3i
8 SFF U.3 backplane, NVMe3
P20865-001
8 SFF U.2 / U.3 backplane
HPE Smart Array Controller
SR932i-p port 2i
8 SFF U.3 backplane, NVMe4
P20866-001
8 SFF U.2 / U.3 backplane
HPE Smart Array Controller
SR932i-p port 1i
SFF cables
202
Содержание HPE ProLiant DL365 Gen10 Plus Server
Страница 7: ...10 5 Regulatory information 10 6 Documentation feedback ...
Страница 8: ...Component identification Component identification 8 ...
Страница 24: ...Device numbers 8 SFF device bay numbering 8 SFF 2 SFF device bay numbering Device numbers 24 ...
Страница 25: ...Drives Drives 25 ...
Страница 29: ...Fan bay numbering Fan bay numbering 29 ...
Страница 30: ...Operations Operations 30 ...
Страница 45: ...Setup Setup 45 ...
Страница 62: ...Hardware options installation Hardware options installation 62 ...
Страница 78: ...Installing an 8 SFF optical drive 78 ...
Страница 79: ...Universal media bay options Universal media bay options 79 ...
Страница 97: ...Secondary PCI riser options Secondary PCI riser options 97 ...
Страница 104: ...Full length Installing an expansion board in the secondary riser cage 104 ...
Страница 118: ...Installing an HPE Smart Array P816i a SR Gen10 Controller option 118 ...
Страница 119: ...Processor and heatsink options Processor and heatsink options 119 ...
Страница 143: ...HPE Trusted Platform Module 2 0 Gen10 Plus option HPE Trusted Platform Module 2 0 Gen10 Plus option 143 ...
Страница 146: ...Installing and enabling the HPE TPM 2 0 Gen10 Plus option Installing and enabling the HPE TPM 2 0 Gen10 Plus option 146 ...
Страница 147: ...Installing the Trusted Platform Module board Installing the Trusted Platform Module board 147 ...
Страница 156: ...Software and configuration utilities Software and configuration utilities 156 ...
Страница 185: ...Keeping the system current Keeping the system current 185 ...
Страница 198: ...Troubleshooting Troubleshooting 198 ...
Страница 200: ...Cabling Cabling 200 ...
Страница 217: ...Support and other resources Support and other resources 217 ...