Installing a heatsink
Installing a heatsink
This procedure shows a standard heatsink as an example. The installation process is the same for both the standard and high-
performance heatsinks.
Hewlett Packard Enterprise recommends identifying the processor and socket components before performing this procedure.
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
The components included with the hardware option kit
T-20 Torx screwdriver
1.0 gm (0.5 ml) or two 0.5 gm (0.25 ml) of thermal grease
Alcohol wipe
Procedure
Procedure
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
5. Remove the air baffle.
6. Allow the existing heatsink to cool.
7. Remove the heatsink:
CAUTION:
CAUTION:
To prevent mechanical damage or depositing oil on your hands or other contaminant to the heatsink contact
surface, hold the heatsink only by the edge of its base plate. Do not touch the heatsink fins.
CAUTION:
CAUTION:
Heatsink screws must be tightened and loosened in alternating sequence. Do not overtighten the screws as this
might damage the system board or the processor socket.
a. Use a T-20 Torx screwdriver to loosen the captive screws in the sequence specified on the heatsink label.
b. Lift the heatsink away from the system board.
Installing a heatsink
125
Содержание HPE ProLiant DL365 Gen10 Plus Server
Страница 7: ...10 5 Regulatory information 10 6 Documentation feedback ...
Страница 8: ...Component identification Component identification 8 ...
Страница 24: ...Device numbers 8 SFF device bay numbering 8 SFF 2 SFF device bay numbering Device numbers 24 ...
Страница 25: ...Drives Drives 25 ...
Страница 29: ...Fan bay numbering Fan bay numbering 29 ...
Страница 30: ...Operations Operations 30 ...
Страница 45: ...Setup Setup 45 ...
Страница 62: ...Hardware options installation Hardware options installation 62 ...
Страница 78: ...Installing an 8 SFF optical drive 78 ...
Страница 79: ...Universal media bay options Universal media bay options 79 ...
Страница 97: ...Secondary PCI riser options Secondary PCI riser options 97 ...
Страница 104: ...Full length Installing an expansion board in the secondary riser cage 104 ...
Страница 118: ...Installing an HPE Smart Array P816i a SR Gen10 Controller option 118 ...
Страница 119: ...Processor and heatsink options Processor and heatsink options 119 ...
Страница 143: ...HPE Trusted Platform Module 2 0 Gen10 Plus option HPE Trusted Platform Module 2 0 Gen10 Plus option 143 ...
Страница 146: ...Installing and enabling the HPE TPM 2 0 Gen10 Plus option Installing and enabling the HPE TPM 2 0 Gen10 Plus option 146 ...
Страница 147: ...Installing the Trusted Platform Module board Installing the Trusted Platform Module board 147 ...
Страница 156: ...Software and configuration utilities Software and configuration utilities 156 ...
Страница 185: ...Keeping the system current Keeping the system current 185 ...
Страница 198: ...Troubleshooting Troubleshooting 198 ...
Страница 200: ...Cabling Cabling 200 ...
Страница 217: ...Support and other resources Support and other resources 217 ...