7.
Remove the existing PCI riser cage.
Retain the cage for future use.
Install the PCI riser cage
CAUTION:
To prevent damage to the server or expansion boards, power down the server, and
disconnect all power cords before removing or installing the PCI riser cage.
To install the component:
1.
If cabled expansion boards are installed on the PCI riser cage, connect all necessary internal cabling
to the expansion boards.
For more information on these cabling requirements, see the documentation that ships with the
option.
2.
Align the riser board with the corresponding connectors on the system board, and then press down
the PCI riser cage.
3.
Install the access panel (on page
21
).
4.
Do one of the following: