Operations 18
Before proceeding, verify the server is in standby mode by observing that the system power LED is
amber.
Extend the server from the rack
WARNING:
To reduce the risk of personal injury or equipment damage, be sure that the rack
is adequately stabilized before extending a component from the rack.
1.
Power down the server (on page
17
).
2.
Disconnect all peripheral cables from the server.
3.
Disconnect each power cord from the server.
4.
In a server that uses thumbscrew rack ears, loosen the captive thumbscrews that secure the server
faceplate to the front of the rack, and then slide the server out of the rack.
5.
In a server that uses quick-release latch rack ears:
a.
Open the latches on both sides of the server.
b.
If necessary, use a T-25 Torx screwdriver to loosen the shipping screws.