96
Digitizer Command Reference
•
MASTer<n> and SLAVe<n> pairs a sample line and a trigger line which are
then used for multiple unit synchronization. See the section titled “Master-
Slave Operation” in Chapter 2 for more information including diagrams.
Comments
•
Executable when initiated: Yes
•
Coupled command: No
•
Reset (*RST) condition: NORMal mode
:MODE?
TRIGger:MODE? queries the trigger mode setting. Returns NORMal, MASTer
or SLAVe.
:SLOPe[<n>]
TRIGger:SLOPe[<n>]
POS | 1 | NEG | 0 sets the active edge of the trigger signal
which causes a measurement to be made. There are two trigger sources and you must
designate which source you are setting the slope. n = 1 for the slope of trigger source
number 1. n = 2 for the slope of trigger source number 2. Trigger slope defaults to
n=1 if “n” is not designated.
Parameters
Note
Trigger slope is active only when the trigger source is one of the four INTernal
levels (TRIG:SOURce INT1-4) or when the EXTernal trigger source is specified
(TRIG:SOURce EXTernal).
Comments
•
Executable when initiated: Yes
•
Coupled command: TRIG:SOURce INT1-4 and TRIG:SOURce EXTernal
TTLT pairs to SLAVe modules
MASTer MODE
SLAVe MODE
Sample line
Trigger line
MASTer0
SLAVe0
TTLT0
TTLT1
MASTer2
SLAVe2
TTLT2
TTLT3
MASTer4
SLAVe4
TTLT4
TTLT5
MASTer6
SLAVe6
TTLT6
TTLT7
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
n
numeric
1 or 2
None