1 Cisco Catalyst Blade Switch 3120 Disabled
2 Absent Disabled
3 Absent Disabled
4 Absent Disabled
SHOW INTERCONNECT STATUS
•
Command:
SHOW INTERCONNECT STATUS {ALL | <bay number>
| <bay number>-<bay number>}
•
Description:
Displays interconnect status information; UID state and health state
•
Access level/Bay level:
All
◦
◦
Bay specific
•
Restrictions:
You must have explicit access to a bay given by the
ASSIGN INTERCONNECT
command.
•
Example:
OA-0018FE27577F> SHOW INTERCONNECT STATUS ALL
Interconnect Module #1 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Internal Data OK
Management Processor OK
Thermal Warning OK
Thermal Danger OK
I/O Configuration OK
Device Failure OK
Device Degraded OK
Interconnect Module #2 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #3 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #4 Status:
Interconnect Module Type: No Interconnect Module Installed
SHOW XFM INFO
•
Command:
SHOW XFM INFO { ALL | <xfm_number> {[ - | , ] <xfm_number>} }
SHOW INTERCONNECT STATUS
115
Содержание Compaq Presario,Presario 2816
Страница 107: ...Link 2 OK Link N FAILED IO Slots Status Bay Slot Status 1 1 OK 1 2 OK SHOW IOX STATUS 107 ...
Страница 118: ...Link 7 Unknown Link 8 Unknown 1 18 Interconnect management commands ...
Страница 127: ... Access level Bay level Operator or Admin Restriction You must be connected to the monarch OA ICAPMODIFY 127 ...
Страница 213: ...Xbar Crossbar XFM Xbar Fabric module XML Extensible markup language 213 ...