SHOW INTERCONNECT PORT MAP
•
Command:
SHOW INTERCONNECT PORT MAP {ALL | <bay number>
| <bay number>-<bay number>}
•
Description:
Displays the port mapping for the interconnect specified by the bay number
•
Access level/Bay level:
All
◦
◦
Bay specific
•
Restrictions:
You must have explicit access to a bay given by the
ASSIGN INTERCONNECT
command.
•
Example:
OA-0018FE27577F> SHOW INTERCONNECT PORT MAP ALL
1: Cisco Catalyst Blade Switch 3120X for HP w/ IP Base
Type: Ethernet
Width: Single
Status: OK
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Status OK OK OK OK
Blade 2A 7 2B 7
Mezz/Nic NI NI NI NI
Port 1 1 1 2
2. <absent>
3. <absent>
4. <absent>
SHOW INTERCONNECT POWERDELAY
•
Command:
SHOW INTERCONNECT POWERDELAY {ALL | <bay number> [{ - | , }
<bay number>]}
•
Description:
Displays the PowerDelay status for the specified interconnects or range of interconnects
•
Access level/Bay level:
All
◦
◦
Bay specific
•
Restrictions:
None
•
Example:
OA-0018FE27577F> SHOW INTERCONNECT POWERDELAY ALL
Current PowerDelay Status: Not in Progress
Bay Device PowerDelay State Delay (seconds)
--- -------------------------------- ------------
114
Interconnect management commands
Содержание Compaq Presario,Presario 2816
Страница 107: ...Link 2 OK Link N FAILED IO Slots Status Bay Slot Status 1 1 OK 1 2 OK SHOW IOX STATUS 107 ...
Страница 118: ...Link 7 Unknown Link 8 Unknown 1 18 Interconnect management commands ...
Страница 127: ... Access level Bay level Operator or Admin Restriction You must be connected to the monarch OA ICAPMODIFY 127 ...