![background image](http://html.mh-extra.com/html/hp/compaq-presario-presario-2816/compaq-presario-presario-2816_user-manual_159929103.webp)
•
Access level/Bay level:
All
•
Restrictions:
None
•
Example:
sphere-oa2> show blade status 1
Blade #1 Status:
Power: On
Current Wattage used: 1325 Watts
Health: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Management Processor OK
I/O Configuration OK
Power OK
Cooling OK
Device Failure OK
Device Degraded OK
Device Info OK
Firmware Mismatch OK
PDHC OK
Indicted OK
SHOW BLADE TEMP
•
Command:
SHOW BLADE TEMP {ALL | <bay number> [{ , | - } <bay number>]}
NOTE:
SERVER
is a valid alias for
BLADE
.
•
Description:
Displays the temperature sensor information for a specified blade or range of blades
•
Access level/Bay level:
All
◦
◦
Bay specific
•
Restrictions:
You must have access to the specified bay number.
•
Example:
sphere-oa2> show blade temp 1
Device Bay #1 Temperature Information
Locale Status Temp Caution Critical
----------------------------------- ------ -------- ------- --------
Memory Zone OK 25C/ 77F 40C 50C
Memory Zone OK 25C/ 77F 40C 50C
Memory Zone OK 26C/ 78F 40C 50C
Memory Zone OK 24C/ 75F 40C 50C
Ambient Zone OK 23C/ 73F 32C 37C
System Zone OK 29C/ 84F 65C 70C
System Zone OK 27C/ 80F 65C 70C
System Zone OK 26C/ 78F 65C 70C
SHOW BLADE TEMP 103
Содержание Compaq Presario,Presario 2816
Страница 107: ...Link 2 OK Link N FAILED IO Slots Status Bay Slot Status 1 1 OK 1 2 OK SHOW IOX STATUS 107 ...
Страница 118: ...Link 7 Unknown Link 8 Unknown 1 18 Interconnect management commands ...
Страница 127: ... Access level Bay level Operator or Admin Restriction You must be connected to the monarch OA ICAPMODIFY 127 ...
Страница 213: ...Xbar Crossbar XFM Xbar Fabric module XML Extensible markup language 213 ...