IMPORTANT:
In most cases resumption of function will not cause automatic acquittal.
Component replacement, complex AC power cycle or manual acquittal is required. Examples
are:
◦
BPS indicted for loss of AC input regains power input.
◦
Environmental temperature returns to within acceptable bounds.
◦
Enclosure regains sufficient power due to BPS replacement.
◦
Enclosure regains sufficient cooling due to fan replacement.
Viewing the list of indicted components
The
show indict
command will list the currently indicted components for the complex describing
the type, physical location, indication of the cause for indictment, and timestamp.
myhost HR> show indict
System Indictment List - Mon May 18 16:06:03 2009
--------------------------------------------------
FRU Type: Blade DIMM
Location: 0x0100FF0200160A74 enclosure1/blade2/socket0/dimm16
Timestamp: Mon May 18 15:51:12 2009
Indictment State: Indicted
Requested Deconfig State: Configured
Current Deconfig State: Configured
FRU Type: CPU Socket
Location: 0x0100FF01FF00FF11 enclosure1/blade1/socket0
Timestamp: Mon May 18 16:05:57 2009
Indictment State: Indicted
Requested Deconfig State: Configured
Current Deconfig State: Configured
--- end report --- 2 records shown
Viewing deconfigured components
The
show deconfig
will list all components in the complex which are deconfigured or have a
pending request to be deconfigured. The output includes the type, physical location, indication of
the cause for indictment, and timestamp.
myhost HR> show deconfig
System Acquittal History - Mon May 18 16:11:28 2009
--------------------------------------------------
FRU Type: Blade DIMM
Location: 0x0100FF0200160A74 enclosure1/blade2/socket0/dimm16
Timestamp: Mon May 18 16:11:19 2009
Indictment State: Indicted
Requested Deconfig State: Configured
Current Deconfig State: Deconfigured
FRU Type: CPU Socket
Location: 0x0100FF01FF00FF11 enclosure1/blade1/socket0
Timestamp: Mon May 18 16:11:19 2009
Indictment State: Indicted
Requested Deconfig State: Configured
Current Deconfig State: Deconfigured
204 Using event logs
Содержание Compaq Presario,Presario 2816
Страница 107: ...Link 2 OK Link N FAILED IO Slots Status Bay Slot Status 1 1 OK 1 2 OK SHOW IOX STATUS 107 ...
Страница 118: ...Link 7 Unknown Link 8 Unknown 1 18 Interconnect management commands ...
Страница 127: ... Access level Bay level Operator or Admin Restriction You must be connected to the monarch OA ICAPMODIFY 127 ...
Страница 213: ...Xbar Crossbar XFM Xbar Fabric module XML Extensible markup language 213 ...