Restrictions:
You must have access to the specified bay number.
•
Example:
OA-0018FE27577F> SHOW SERVER POWERDELAY ALL
Current PowerDelay Status: Not in Progress
Bay Device PowerDelay State Delay (seconds)
--- -------------------------------- ------------
1 Absent Disabled
1A Absent Disabled
1B Absent Disabled
2 Subsumed Disabled
2A ProLiant BL2x220c G5 Disabled
2B ProLiant BL2x220c G5 Disabled
3 Absent Disabled
3A Absent Disabled
3B Absent Disabled
4 Absent Disabled
4A Absent Disabled
4B Absent Disabled
5 Absent Disabled
5A Absent Disabled
5B Absent Disabled
6 Absent Disabled
6A Absent Disabled
6B Absent Disabled
7 ProLiant BL460c G1 Disabled
7A Absent Disabled
7B Absent Disabled
8 AiO SB600c Storage Disabled
8A Absent Disabled
8B Absent Disabled
SHOW BLADE STATUS
•
Command:
SHOW BLADE STATUS {ALL | <bay number> [{ , | - } <bay number>]}
NOTE:
SERVER
is a valid alias for
BLADE
.
•
Description:
Displays the following settings of server blade:
◦
Power (OK or off)
◦
Health (OK, CPU failure, or power module failure)
◦
Thermal (OK, warm, caution, or critical)
◦
UID LED
102 Blade management commands
Содержание Compaq Presario,Presario 2816
Страница 107: ...Link 2 OK Link N FAILED IO Slots Status Bay Slot Status 1 1 OK 1 2 OK SHOW IOX STATUS 107 ...
Страница 118: ...Link 7 Unknown Link 8 Unknown 1 18 Interconnect management commands ...
Страница 127: ... Access level Bay level Operator or Admin Restriction You must be connected to the monarch OA ICAPMODIFY 127 ...
Страница 213: ...Xbar Crossbar XFM Xbar Fabric module XML Extensible markup language 213 ...