Syntax
front-panel-security diagnostic-reset
<CLEAR-BUTTON | SERIAL-CONSOLE>
Description
Enables the diagnostic reset so that the switch can capture diagnostic data.
• To initiate diagnostic reset via the clear button, press the clear button for at least 30 seconds but not more than
40 seconds.
• To initiate diagnostic switch reset via the serial console, enter the diagnostic reset sequence on the serial
console.
Options
Clear button
Enables the diagnostics by choosing the clear button option.
Serial console
Enables the diagnostics by choosing the serial console option.
[no] front-panel-security diagnostic-reset
From the configure context:
Syntax
[no] front-panel-security diagnostic-reset
Description
Disables the diagnostic reset feature so that the user is prevented from capturing diagnostic data and performing
a diagnostic reset on the switch. Both the sub-options
reset-via-serial-console
and
reset-via-clear-
button
will be disabled. This is necessary if the switch becomes unresponsive (hangs) for unknown reasons.
No front-panel-security diagnostic-reset
no front-panel-security diagnostic-reset
Clear Password - Enabled
Reset-on-clear - Disabled
Factory Reset - Enabled
Password Recovery - Enabled
Diagnostic Reset - Disabled
CAUTION:
Disabling the diagnostic reset prevents the switch from capturing diagnostic data on those rare
events where the switch becomes unresponsive to user input because of unknown reasons. Ensure
that you are familiar with the front panel security options before proceeding.
Front-panel-security diagnostic-reset clear-button
From the configure context:
580
Aruba 2930F / 2930M Management and Configuration Guide
for ArubaOS-Switch 16.08