T
able
1-1.
Required
Equipment
for
the
A
djustments
and
P
erformance
T
ests
Description
HP
Model
#
50
STD
75
Opt
1EC
Notes
ADJ
PERF
ADJ
PERF
Function
generator
HP
8116A
X
X
X
X
No
substitute
P
ower
meter
HP
437B
,
HP
438A
X
X
X
X
Do
not
use
an
HP
436A.
P
ower
sensor
,
50
HP
8482A
X
X
X
X
P
ower
sensor
,
75
HP
8483A
-
-
-
X
Low
power
sensor
HP
8481D
X
-
X
-
F
or
option
1E1
(atten)
units
only
Cal
kit
type-N
50
HP
85032B
Option
001
1
X
X
-
-
Cal
kit
type-N
75
HP
85036B
-
-
X
X
10
dB
step
attenuator
HP
8496A/G
X
X
X
X
Attenuator/switch
driver
HP
11713A
X
X
X
X
Needed
for
\G"
version
step
attenuators
only
Spectrum
analyzer
HP
8560
series
,
HP
8566B
X
X
X
X
Others
may
be
substituted,
optional
for
adjustments
30
MHz
bandpass
lter
9135-0475
-
-
-
-
May
not
be
required
2
20
dB
attenuator
50
HP
8491A/B/C
Opt
020
X
X
-
-
Required
for
adjustments
only
if
analyzer
does
not
have
option
1E1
installed.
20
dB
attenuator
75
3
0955-0758
-
-
X
X
See
note
for
50
20
dB
attenuator
above
.
10
dB
attenuator
50
HP
8491A/B/C
Opt
010
X
-
-
-
May
not
be
required
for
HP
8713B/14B
6
dB
attenuator
50
HP
8491A/B/C
Opt
006
X
X
-
-
3
dB
attenuator
50
HP
8491A/B/C
Opt
003
-
X
-
-
3
dB
attenuator
75
0955-0765
-
-
-
X
P
ower
splitter
,
50
0955-0751,
11667A
-
X
-
-
P
ower
splitter
,
75
0955-0752
-
-
-
X
Minimum
loss
pad
(2)
HP
11852B
-
-
X
X
One
for
adjustments
,
two
for
performance
tests
.
Frequency
counter
HP
5342/3A,
5350B
-
-
-
-
May
not
be
required.
4
Precision
cable
50
8120-4781
X
X
X
X
Precision
cable
75
8120-2408
-
-
X
-
Service
kit
08712-60012
X
-
X
-
1
An
HP
85032B
Option
001
is
a
subset
of
the
standard
HP
85032B
.
This
eliminates
two
7-mm
adapters
that
are
not
needed,
resulting
in
a
signicant
cost
savings
.
2
The
30
MHz
bandpass
lter
is
used
to
eliminate
harmonics
from
the
external
source
.
Its
use
is
not
required
unless
harmonics
are
worse
than
030
dBc
.
3
The
75
20
dB
attenuator
can
be
substituted
with
two
minimum
loss
pads
and
a
50
10
dB
attenuator
.
NOTE:
a
set
of
75
attenuators
(3,6,10,20
dB)
is
available
as
HP
86213A.
4
The
frequency
counter
is
useful
when
very
accurate
frequency
measurements
are
needed.
However
,
if
you
are
using
a
synthesized
spectrum
analyzer
,
the
frequency
can
be
measured
by
using
the
analyzer
(thus
eliminating
another
piece
of
equipment).
Note
that
the
frequency
measurement
using
a
spectrum
analyzer
will
not
be
quite
as
accurate
as
a
frequency
counter
,
but
it
is
sucient
in
most
cases
.
P
erformance
T
ests
1-11
Содержание 87114B
Страница 7: ......
Страница 19: ...Absolute Power Accuracy broadband Dynamic Accuracy narrowband 1 4 Performance T ests ...
Страница 39: ......
Страница 73: ......
Страница 89: ......
Страница 115: ......
Страница 116: ......
Страница 118: ...Figure 5 1 The Service Key Menus 5 2 Service Related Menus ...
Страница 132: ......
Страница 162: ......
Страница 164: ......
Страница 170: ......