![HP 87114B Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/hp/87114b/87114b_service-manual_161524051.webp)
Set
Serial
Number
,
A
djustment
#100
This
procedure
shows
you
how
to
store
the
analyzer's
serial
number
in
the
CPU
bootROM.
While
this
is
not
normally
required,
you
may
have
to
perform
this
procedure
when
you
replace
the
CPU
board.
Y
ou
can
only
perform
this
procedure
over
HP-IB
,
so
an
HP
B
ASIC
controller
(either
external
or
IB
ASIC)
is
required.
The
performance
test
software
(HP
part
number
08712-10011)
can
also
be
used
to
store
the
analyzer's
serial
number
.
Note
Where
XXXXXXXXXX
appears
throughout
this
procedure
,
replace
those
characters
with
the
serial
number
of
your
analyzer
but
maintain
the
leading
and
following
apostrophes
(both
are
ASCII
character
39).
F
or
example
,
if
the
serial
number
of
your
analyzer
is
US34405555,
the
HP
B
ASIC
line
of
code
would
be:
OUTPUT
716;"DIAG:SNUM
'US34405555'"
IMPORT
ANT:
Make
sure
there
is
a
space
between
SNUM
and
the
rst
apostrophe
.
Required
Equipment
A
computer
with
HP-IB
capabilities
is
required.
If
IB
ASIC
(option
1C2)
is
installed,
an
IBM
PC-A
T
style
keyboard
is
the
only
requirement.
Estimated
A
djustment
Time
This
adjustment
takes
approximately
two
minutes
to
perform.
Procedure
1.
Write
down
the
10-character
serial
number
,
exactly
as
shown
on
the
analyzer
rear-panel
label.
2.
Use
one
of
the
following
B
ASIC
commands
to
set
the
serial
number:
(Replace
the
XXXXXXXXXX
in
the
command
with
your
analyzer's
serial
number
.)
a.
If
you
are
using
HP
B
ASIC
from
an
external
controller
,
enter:
OUTPUT
716;"DIAG:SNUM
'XXXXXXXXXX'"
then
press
4
ENTER
5 .
On
the
analyzer
,
press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Return
to
Local
.
This
assumes
that
the
analyzer
is
at
address
16
and
the
HP-IB
is
at
7.
If
not,
either
use
the
analyzer's
actual
address
,
or
change
the
analyzer's
address
to
16.
b.
If
you
are
using
IB
ASIC:
With
an
external
keyboard
connected,
press
4
ESC
5
to
view
the
IB
ASIC
command
line
.
Then
type
the
following:
OUTPUT
800;"DIAG:SNUM
'XXXXXXXXXX'"
and
press
4
ENTER
5 .
c.
Press
4
SYSTEM
OPTIONS
5
NNNNNNNNNNNNNNNNNNNNNNN
Service
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Instrument
Info
to
verify
that
you
correctly
installed
the
serial
number
.
The
serial
number
is
displayed
in
the
dialogue
box.
2-12
Adjustments
Содержание 87114B
Страница 7: ......
Страница 19: ...Absolute Power Accuracy broadband Dynamic Accuracy narrowband 1 4 Performance T ests ...
Страница 39: ......
Страница 73: ......
Страница 89: ......
Страница 115: ......
Страница 116: ......
Страница 118: ...Figure 5 1 The Service Key Menus 5 2 Service Related Menus ...
Страница 132: ......
Страница 162: ......
Страница 164: ......
Страница 170: ......