Table 4-10.
Maximum Leveled Output Power Test Work Sheet
Frequency Range: 10 MHz to 2.3 GHz
Power Meter
HP 8340B141 B
Indication
Entry Display
Step 14
Minimum
_____________________________
_____________________________________
Step 15
Maximum
____________________________
_____________________________________
Step 18
Flatness:
Maximum
-
Minimum
(=1.2dB, Standard)
(=1.4dB, Option 004)
(=1.2dB, Option 001)
(=1.4dB, Option 005)
Frequency Range: 2.3 GHz to 7.0 0Hz
Power Meter
HP 8340B141B
Indication
Entry Display
Step 14
Minimum
_____________________________
_____________________________________
Step 15
Maximum
____________________________
Step 18
Flatness:
Maximum
-
Minimum
(=2.2dB, Standard)
(=2.6dB, Option 004)
(=1.8dB, Option 001)
(=2.2dB, Option 005)
Frequency Range: 7.0 GHz to 13.5 GHz
Power Meter
HP 8340B141B
Indication
Entry Display
Step 14
Minimum
______________________________
Step 15
Maximum
____________________________
Step 18
Flatness:
Maximum
-
Minimum
(=2.2dB, Standard)
(=2.6dB, Option 004)
(=1.8dB, Option 001)
(=2.2dB, Option 005)
Frequency Range: 13.5 0Hz to 20.0 0Hz
Power Meter
HP 8340B141B
Indication
Entry Display
Step 14
Minimum
_____________________________
_____________________________________
Step iS
Maximum
____________________________
Step 18
Flatness:
Maximum
-
Minimum
(=2.2dB, Standard)
(=2.6dB, Option 004)
(=1.8dB, Option 001)
(=2.2dB, Option 005)
Frequency Range: 20.0 0Hz to 26.5 GHz
(Applies to the HP 8340B only)
Power Meter
HP 834GB
Indication
Entry Display
Step 14
Minimum
______________________________
______________________________________
Step 15
Maximum
____________________________
_____________________________________
Step 18
Flatness:
Maximum
-
Minimum
(=3.2dB, Standard)
(=3.6dB, Option 004)
(=2.6dB, Option 001)
(=3.0dB, Option 005)
HP 8340B/41B
Performance Tests
4-31/4-32