C
Output
power:
The
maximum
output
power
for
the
specied
TLS
tuning
range
.
Conditions:
temperature
within
operating
temperature
range
.
Measurement
with
power
meter
at
the
end
of
a
single-mode
ber
patchcord.
P
eak
power:
The
highest
optical
power
within
specied
wavelength
range
.
P
olarization
extinction
ratio:
The
ratio
of
optical
power
in
the
slow
axis
of
the
polarization-maintaining
ber
to
optical
power
in
the
fast
axis
within
a
specied
wavelength
range
.
Conditions:
only
for
TLS
with
polarization
maintaining
ber
,
TE
mode
in
slow
axis
and
oriented
in
line
with
connector
key
.
Measurement
with
rotatable
polarizer
at
the
end
of
a
polarization-maintaining
patchcord,
with
polarizer
orientations
for
the
fast
and
slow
axes
kept
xed
while
changing
the
wavelength.
P
ower
atness:
When
changing
the
wavelength
and
measuring
the
dierences
between
actual
and
displayed
power
levels
,
the
power
atness
is
6
half
the
span
between
the
maximum
and
the
minimum
value
of
all
dierences
relative
to
the
mean
power
.
Conditions:
uninterrupted
line
voltage
,
constant
power
setting,
temperature
within
61
K.
Measurement
with
optical
power
meter
.
P
ower
linearity:
When
changing
the
power
level
and
measuring
the
dierences
between
actual
and
displayed
power
levels
,
the
power
linearity
is
6
half
the
span
between
the
maximum
and
the
minimum
value
of
all
dierences
.
Conditions:
uninterrupted
TLS
line
voltage
,
constant
wavelength-
and
power
level
settings
,
temperature
within
61
K.
Measurement
with
optical
power
meter
.
P
ower
repeatability:
The
random
uncertainty
in
reproducing
the
power
level
after
changing
and
re-setting
the
power
level
or
wavelength.
The
power
repeatability
is
6
half
the
span
between
the
maximum
and
the
minimum
value
of
all
dierences
relative
to
the
mean
power
.
Conditions:
uninterrupted
TLS
line
voltage
,
constant
wavelength,
temperature
within
61
K.
Measurement
with
optical
power
meter
.
P
ower
stability:
The
change
of
the
power
level
during
a
given
time
span,
expressed
as
6
half
the
span
of
power
changes
relative
to
the
mean
power
.
Conditions:
uninterrupted
TLS
line
voltage
,
constant
wavelength-
and
power
level
settings
,
temperature
within
61
K,
time
span
as
specied.
Measurement
with
optical
power
meter
.
C-2
Specications
Содержание 8167A
Страница 2: ......
Страница 4: ......
Страница 26: ......
Страница 110: ......
Страница 130: ......
Страница 150: ......
Страница 164: ...D Figure D 1 Test Setup for the Wavelength Tests D 4 Performance Tests ...
Страница 168: ...D Figure D 2 Test Setup for the Maximum Output Power Test except HP 8168F D 8 Performance Tests ...
Страница 177: ...D Figure D 5 Test Setup for the Source Spontaneous Emission Test Performance Tests D 17 ...
Страница 240: ......