2.
Set the switches on the rear panel of your plotter as shown in the
following diagram. Your plotter checks the switch settings only
when you turn it on, so be sure the plotter is turned off before
changing switch settings.
SET Sl TO
-0·
FOR
SET TO US POSITION FOR A AND B
PAPER OR TO MET FOR A4 AND A3
PAPER,
SET TO A4 FOR A AND A4 PAPER
OR TO A3 FOR B AND A3 PAPER.
SET 84 and 82 TO · 1 " AND 83 AND B1
TO
"0"
FOR
9600
BAUD RATE,
NO PARITY, SETTING
SET TO POSITION
"0"
FOR ENOLlNE
OF S2 IS IRRELEVANT,
OPERATING ENVIRONMENT.
3.
Configure your computer system as follows. (Refer to your com
puter documentation
if
you have difficulty with this step.)
a. Load the MS-DOS System Disc. Touch
DEVICE CON FIG.
Then
touch
START APPLIC
to display the
DEVICE CONFIGURATION
screen.
b. Touch the
PLT
field, then use the
NEXT CHOICE
key to select
PLT:
PORT
2.
Next, touch
SAVE CONFIG.
c. Press the
USERlSYSTEM
key on your keyboard twice to change
the function key selections. Then select
CONFIG KEYS.
d. Select the
PORT 2 CONFIG
field to display the
PORT 2
screen.
Press the
SYSTEM DEFAULTS
key, then the
DEFAULT VALUES
key.
Use the
NEXT CHOICE
key to select
BAUD RATE
9600.
Then use the
cursor controls to select the
CS(CB)XMlT
field. Use the
NEXT
CHOICE
key to set the field to
YES.
e. Touch
SAVE CONFIG
to save the new configuration. Hold down
the
SHIFT
key and press the
USER/SYSTEM
key. Press the
EXIT
CONFIG
to return to P.A.M.
PLOTTER INTERCONNECTION
3-23
Содержание 7475a
Страница 1: ... FliOW HEWLETT PACKARD HP 7475A Graphics Plotter ...
Страница 2: ...OPERATION HP 7475A AND Graphics Plotter INTERCONNECTION MANUAL ...
Страница 8: ...f i oil I V J ...
Страница 18: ......
Страница 51: ...NOTES ...
Страница 52: ......
Страница 80: ......
Страница 86: ...NOTES ...
Страница 100: ...NOTES ...