of PI and P2 and the physical size of the input window. Whether
invoked manually or programmatically, rotations are not cumulative,
and the rotate function can only be toggled on or off.
When the 90-degree rotate function is invoked with the
ENTER
+
FAST
buttons, the default input window remains coincident with the hard
clip limits and PI and P2 assume new rotated default coordinate loca
tions inside the hard-clip limits. These new Pl/P2 values are shown in
the following table. Note that the physical location and size of the
PlIP2 frame are not affected by the front-panel rotate function.
Rotated Default Coordinate Values for Scaling Points PI and P2
Rotated Default Scaling Points (Plotter Units)
Paper
Size
Plx,Ply
P2x,P2y
A
154 , 244
7354 , 10 244
A4
0 , 610
7200 , 10610
B
283 , 934
10283 , 16 134
A3
607 , 797
10607 , 15 997
When the 90-degree rotate function is invoked with an R090 instruc
tion, PI and P2 retain their current coordinate values and may therefore
be rotated outside the hard·clip limits as shown in the following illus
tration. The default input window is also rotated, but its physical size is
clipped to a square area by the hard-clip limits. Note that the input
window limits programmed pen motion to the window area, but the pen
can still be moved anywhere within the hard-clip limits using the front
panel cursor buttons. The input window can be expanded to the hard
clip limits and PI and P2 can be defaulted to the rotated default coor
dinate values using the HP-GL instructions, IW and lP, without
parameters.
Whether invoked manually or programmatically, the physical size and
location of the hard-clip limits are not affected by the rotate function.
However, the defined lower-left
(LL)
and upper-right (UR) corners of the
hard-clip limits are rotated to maintain the same relationship with
respect to the 0 , 0 origin point. The coordinate values for UR are deter
mined by paper size and the state of the rotate function; but, the coor
dinate values for LL will always by 0 , 0 regardless of paper size and
the state of the rotate function. The current plotter unit coordinate
values for
LL
and UR can be obtained by executing the Hp·GL instruc
tion, OH.
PLOTIER OPERATION
2-13
Содержание 7475a
Страница 1: ... FliOW HEWLETT PACKARD HP 7475A Graphics Plotter ...
Страница 2: ...OPERATION HP 7475A AND Graphics Plotter INTERCONNECTION MANUAL ...
Страница 8: ...f i oil I V J ...
Страница 18: ......
Страница 51: ...NOTES ...
Страница 52: ......
Страница 80: ......
Страница 86: ...NOTES ...
Страница 100: ...NOTES ...