Versus
Draws a volts versus volts display of the two selected operands.
The bandwidth of both the X and Y axis is the full bandwidth of the
oscilloscope’s vertical input. Use versus to compare frequency and phase
relationships between two signals.
Integrate
Calculates the integral of operand 1. Use integrate to
calculate the energy of a pulse in volt-seconds.
Differentiate
Calculates the discreet derivative of operand 1. Use
differentiate to observe the rate at which a signal is changing. For
example, you can observe the slew rate of an operational amplifier.
Min
Minimum stores the minimum value acquired in each time bucket
on operand 1.’
Max
Maximum stores the maximum value acquired in each time bucket
on operand 1
The results for minimum and maximum are recalculated when any of the
following occurs:
•
Time base scale, position, or reference is changed.
•
Channel state, scale, or offset is changed.
•
Trigger definition is changed.
•
Acquisition mode, record length, or sampling rate is changed.
•
Additional data is stored to a waveform memory that is used as part of a
function.
•
The oscilloscope is turned off and on.
•
The Clear display key is pressed.
•
When the Run key is pressed after the oscilloscope was stopped.
FFT magnitude
Generates a new waveform by using a fast Fourier
transform (FFT).
See Also
Chapter 21, "FFT Menu," for a detailed description of the FFT features and
functions.
Math Menu
Define Function
12–5
Содержание 54710A
Страница 7: ...vi ...
Страница 9: ...viii ...
Страница 16: ...Glossary Index Contents Contents 7 ...
Страница 17: ...Contents 8 ...
Страница 65: ...2 16 ...
Страница 72: ...Interpolation turned off Interpolation turned on Figure 3 2 Figure 3 3 Acquisition Menu Interpolate 3 7 ...
Страница 86: ...4 Applications ...
Страница 96: ...6 Display 6 4 Scale 6 5 Offset 6 6 Input 6 6 Probe 6 7 Calibrate 6 10 Channel Menu ...
Страница 98: ...Channel menu and menu map for the HP 54712A plug in Figure 6 1 Channel Menu 6 3 ...
Страница 110: ...7 Thresholds 7 4 Top Base 7 6 Define time 7 8 Statistics 7 9 Define Measure Menu ...
Страница 112: ...Define measure menu and menu map Figure 7 2 Define Measure Menu 7 3 ...
Страница 143: ...8 22 ...
Страница 144: ...9 Persistence 9 3 Color Grade 9 5 Draw waveform 9 6 Graticule 9 10 Label 9 14 Color 9 17 Display Menu ...
Страница 163: ...9 20 ...
Страница 164: ...10 Messages ...
Страница 170: ...11 Off 11 3 Manual 11 3 Waveform 11 5 Measurement 11 7 Marker Hints 11 8 Histogram 11 8 Marker Menu ...
Страница 178: ...12 Function 12 3 Define Function 12 4 Display 12 7 Math Menu ...
Страница 186: ...13 Measurements ...
Страница 199: ...Waveform definitions used to make voltage measurements Figure 13 10 Measurements Voltage Measurements 13 14 ...
Страница 239: ...Response of a Gaussian Filter Versus Frequency Figure 13 26 Measurements Time interval measurements 13 54 ...
Страница 245: ...13 60 ...
Страница 246: ...14 Setup Memory 14 3 Save 14 3 Recall 14 4 Default Setups 14 4 Setup Menu ...
Страница 261: ...15 10 ...
Страница 274: ...17 Scale 17 3 Position 17 3 Reference 17 4 Windowing 17 5 Time Base Menu ...
Страница 282: ...Trigger menu and menu map Figure 18 1 Trigger Menu 18 3 ...
Страница 319: ...19 18 ...
Страница 322: ...20 Waveform 20 3 Pixel 20 6 Waveform Menu ...
Страница 328: ...21 Display 21 3 Source 21 3 Window 21 3 FFT Scaling 21 4 FFTs and Automatic Measurements 21 8 FFT Basics 21 10 FFT Menu ...
Страница 346: ...Limit test menu and menu map Figure 22 2 Limit Test Menu 22 3 ...
Страница 357: ...22 14 ...
Страница 360: ...Mask menu map Figure 23 1 Mask Menu 23 3 ...
Страница 370: ...Figure 23 3 Figure 23 4 Mask Menu Edit Mask 23 13 ...
Страница 407: ...Index 10 ...
Страница 409: ......