- If there is still some unused treatment product left, eliminate any residual
pressure remaining in the apparatus by operating the safety valve (Fig.
16). Recover any possible excess of product and rinse the sprayer again
as indicated above.
- Before using again, even if it is used again immediately, with a different
spraying solution, repeat the rinsing operation 3 consecutive times.
- Before using again, even if it is used again immediately, with the same
treatment product or a different one, check that the sprayer works properly
(especially the valve). treated in 1 min x nozzle output = 100 m²/20 m²/min
x 0.66L/min = 3.3 litres; i.e. 3.3-0.6 = 2.7 litres of water and 0.6 litres of
treatment product.
- This calculation is only given as an indication. During actual use, take into
account the information provided by the manufacturer of the treatment
product and the data on the nozzle output table.
MAINTENANCE
- Periodically, on re-use after overwintering and several times per season,
grease all the joints (with silicone grease for sprayers) and check that the
sprayer is working properly (especially the valve).
- Clean the nozzle and the nozzle holder (Fig. 20)
- Clean the lance filter (Fig. 21)
- Remove the pump (Fig.22)
- Grease or replace the valve and the seals (Fig.22)
EXTENDED COVER
Guarantee period and scope:
- We guarantee our products for a period specified in the specific manual
attached to the product or on the product from their date of purchase
(Compulsory Cover extended to 2 years + Extension of our Contractual
Warranty).
- On failure to present proof of the date of purchase of the products, the
Warranty is effective from the date of manufacture of the product (stated
underneath the product).
Warranty disclaimer:
This Warranty does not cover:
- Normal wear parts: seals, valves, handle, nozzle, piping, carrying straps,
rod and lever,
- Modified products,
- Products whose use contradicts the technical recommendations
stipulated in the User Manuals accompanying the product,
- Products used improperly,
- Products not undergoing regular maintenance,
- Product deteriorations (impacts, falls, crushing, etc.) originating from
negligence, improper maintenance, improper use or abnormal use of the
product,
- The replacement of a component after losing a component of the sprayer.
Warranty activation:
- We ask that you keep proof of purchase (invoice or legible till receipt), as
this will be requested on activation of the Contractual Warranty.
- A product under warranty that has been repaired or replaced, remains
guaranteed for the remaining duration and under the original conditions of
the Contractual Warranty granted at the time of purchase. All returned
products become the property of HOZELOCK-EXEL when replaced by a
new product.
Legal Warranty
- The Mandatory Cover, the conditions of which are recalled hereinabove, does
not replace the Legal Warranty.
STATEMENT OF WARRANTY
General Terms and Conditions
Hozelock provides a manufacturer’s warranty to the initial purchaser for each new
product produced by Hozelock that is sold by an authorised Hozelock supplier in
Australia or New Zealand. This warranty provides such initial purchaser with a
guarantee against faulty workmanship in manufacture and/or defective
components for the warranty period from the date of purchase.
The benefits given by this manufacturer’s warranty are in addition to other rights
and remedies of the consumer under a law in relation to the goods to which this
warranty relates.
Making a Claim
If any product supplied by Hozelock is found to be defective due to faulty
manufacture and/or defective components within the warranty period, Hozelock
will repair or replace the product to the customer providing:
• proof of purchase is provided to Hozelock or its authorized supplier of the
relevant goods
• the fault is not caused by misuse, neglect, adjustments and or modification by the
consumer
• the consumer presents the defective product at the premises of the authorised
supplier of that relevant Hozelock product
• failure has not occurred through normal wear and tear.
The product will be repaired or replaced at Hozelock’s cost however any costs
incurred to obtain warranty consideration or service is the consumer’s
responsibility, including shipping and handling, travel expense, lost time, or pickup
and delivery.
Australia
Our goods come with guarantees that cannot be excluded under the Australia
Consumer Law. You are entitled to a replacement or refund for a major failure and
for compensation for any other reasonably foreseeable loss or damage. You are
also entitled to have the goods repaired or replaced if the goods fail to be of
acceptable quality and the failure does not amount to a major failure.
Hozelock Australia Pty Ltd (ABN 83 154 891 648).
Unit 22 / 456 St Kilda Road, Melbourne, Victoria 3004
Phone: 1300 275175
Email: [email protected]
New Zealand
The manufacturer's warranty is in addition to the rights and remedies provided by
the New Zealand Consumer Guarantees Act
Distributed in New Zealand by:
Horticom (Company No. 463657)
651 Rosebank Road, Avondale, Auckland 1026
Phone: 09 828 4408
FAULTS / SOLUTIONS
-Install the two nuts (B) on the piping
- Install the tubing (A) on the dipping tube (K), then install the pipe (J) on this
assembly.
- Install the piping on the reservoir (Fig.9).
- Install the filter (C) on the piping (J)
- Install the piping on the handle (D) (Fig.9).
- Install the clip (G) on the lance tube (L) (Fig.9).
- Install the two nuts on the lance tube. Install the nozzle on the lance tube
and the tube on the handle. (Fig.9).
- Install the connector, which is present depending on the model, by clipping
or screwing in depending on the model (Fig. 8).
- Install the carrying strap(s), which are present depending on the model
(Fig.10).
- Put the filling filter in place, which is present depending on the model, when
filling the sprayer (Fig.11). Seal the filter on the neck by pulling on the
strings. Remove the filter before closing the sprayer.
- Storing the lance after use (Fig.10)
- Sprayer not compatible with the pressure regulator manufactured by
HOZELOCK-EXEL ref 283983
- Sprayer not compatible with the HOZELOCK telescopic lance ref 4107
COMMISSIONING / SAFETY RULES
- This apparatus is equipped with a switch that allows supply to the lance to be
stopped as soon as the switch is no longer being pressed.
- It is equipped with a safety valve calibrated at the pressure recorded on the
valve or on the reservoir, which limits pressure inside the reservoir.
- The following are recommended:
- Never remove the valve from the apparatus.
- Do not tamper with the operation of the valve.
- For your own safety, the valve must remain in perfect working order.
- Before each pressurizing, check that the valve operates correctly: lift it up
manually and then let go. It should return immediately to its original position. If
this is not the case, do not pressurise the apparatus.
- Check that the apparatus operates correctly by checking there are no leaks
with several litres of water in the reservoir.
- The apparatus must not be used or stored at temperatures under 5°C or over
40°C, neither during overwintering or during the rest of the year (Figs. 1 and 2).
- The solution to be sprayed must not exceed 25°C (Fig. 3).
- Only use in calm weather (no wind).
- Do not use explosive, acidic, and/or corrosive products in the sprayer (Figs. 4
and 5).
- Do not spray in the direction of flames or other heat sources.
- Wear protective clothing, protective gloves, protective goggles and a protective
mask (Fig. 6).
- Do not smoke, eat or drink during use.
- Do not spray in the direction of other people or pets.
- Keep other people and pets at a reasonable distance from the apparatus when
spraying (Fig. 7).
- Help protect the environment, only spray surfaces to be treated.
- Never remove a part of the sprayer without having previously released the
pressure.
- This apparatus must not be used by individuals suffering from fatigue or illness,
or by any person under the influence of alcohol, drugs or other medication.
FILLING
- Follow the manufacturer's instructions for the treatment agents (dosage,
application method, rinsing).
- Only prepare the quantity of agent that is strictly necessary and for one
application. It is advisable to use a filter during filling and to avoid any
overflow.
- Dosing is easy due to the graduation scale on the reservoir.
- Preparation of the solution to be sprayed:
a) Powder product (soluble or wettable): prepare the solution in a bucket
before decanting it into the reservoir through the filling hole.
b) Liquid-based product (to be diluted in water): put 1-2 litres of water into
the tank, pour in the dose of liquid product, then fill up with the required
quantity of water.
DURING USE
- Depending on the apparatus, manually screw the filling cap or the pump on
the reservoir (Fig. 12).
- Pump to pressurise until the valve operates (until a blast of air is released)
(Fig. 13).
- Pressurize the sprayer exclusively with its pump..
- Spray by pressing the handle switch (Fig. 14).
- Adjust the jet by turning the nozzle in both directions (Fig. 15).
- In order to prevent all risks of plug formation, the spray solution must be
prepared in a separate container, before using the filter provided to fill the
sprayer
(Fig. 11).
AFTER USE / CLEANING
After each use:
- Eliminate any residual pressure that may remain in the apparatus
operating the safety valve, by pulling or pushing it depending on the case, or
by spraying until there is no more pressure.
- Avoid risks of pollution by recovering any unused product and its
packaging.
- Wash your hands and face with fresh water after using the sprayer.
- Never store the sprayer pressurised.
- Never store the treatment agent inside the sprayer.
- Never leave the apparatus in a warm environment, nor out in the sun nor
out in the cold (Figs. 1 and 2).
- Store the sprayer in a sheltered location out of the reach of children.
- Clean the handle filter and the suction filter in the reservoir if present in the
sprayer.
- Clean the filling filter (Fig. 23 )
- If you spray until there is just air in the jet: eliminate residual pressure
remaining in the apparatus by operating the safety valve or by spraying until
there is no more pressure (Fig. 16). The residual volume of liquid is less
than 250 ml.
- Before storing and before any other use with another treatment agent,
perform a rinsing operation, i.e. put 1 litre of water into the reservoir for
dilution (Fig. 17), mix thoroughly and operate the apparatus to rinse all of the
sprayer's components. This rinsing operation must be carried out without
removing any of the accessories used during the treatment. This rinsing
mixture must not be emptied into a sewer but must be sprayed outside on
the land that has already been treated.
- Repeat the operation several times before overwintering.
Make sure that all the connectors are fully tightened
Problems
Solutions
Make sure that all the seals are lubricated and clean
and are not damaged or worn. Replace them if
necessary (contact the customer service department).
Clean the nozzle and the filters
Little or no
spraying
The spraying is
not straight
Clean the nozzle
Make sure that all the connectors are fully tightened
Make sure that all the seals are lubricated and clean
and are not damaged or worn. Replace them if
necessary (contact the customer service department).
DANGER: Do not pressurise the appliance Contact
the customer service department
Safety valve
defective
Leaks
WARRANTIES
I the undersigned Jérôme BOULMIER – Quality Manager - certify with this
declaration that the product
Type: Pressure sprayer
Brand : HOZELOCK
Model: Hozelock PURE 7L Sprayer
Ref : 4550
Has been developed, designed and manufactured according to all the
relevant provisions in the "Machine Safety Directive" 2006/42/EC
Signed in Villefranche,
18/08/2016
EC
EC DECLARATION OF CONFORMITY