3.5 Heat output
Note
The performance data listed here applies to the most frequent design conditions. Use the
selection program 'HK-Select' to calculate the performance data for other design data. You can
download 'HK-Select' free of charge on the Internet.
Fresh air temperature
-5 °C
-15 °C
LPHW
Size
Type
Q
Q
TG
H
max
t
S
∆p
W
m
W
Q
Q
TG
H
max
t
S
∆p
W
m
W
°C
kW
kW
m
°C
kPa
l/h
kW
kW
m
°C
kPa
l/h
80/60
LKW-6
C
75
60
8.6
52
12 3210
79
59
8.7
51
13 3399
60/40
LKW-6
C
47
33
11.3
36
5 2035
52
32
11.5
36
6 2225
80/60
LKW-9
C
112
93
9.2
53
10 4823
118
91
9.3
52
11 5070
LKW-9
D
–
–
–
–
–
–
–
–
–
–
–
–
60/40
LKW-9
C
70
51
12.1
37
4 3020
76
49
12.4
36
5 3269
LKW-9
D
86
67
10.7
42
5 3680
93
66
10.8
42
6 3977
80/60
LKW-10
C
125
98
10.2
51
12 5347
133
95
10.4
50
13 5684
LKW-10
D
151
124
9.2
60
13 6481
161
124
9.2
60
14 6887
60/40
LKW-10
C
80
53
13.7
36
5 3414
87
50
14.0
35
7 3753
LKW-10
D
98
71
11.9
42
6 4192
107
70
12.0
41
7 4601
Legend:
Type =
Type of heating/cooling coil
Q
=
Heat output
Q
TG
=
Output to cover fabric heat losses
H
max
=
Maximum mounting height
t
S
=
Supply air temperature
∆p
W
=
Water pressure drop
m
W
=
Water flow rate
Refers to:
Room air 18 °C, extract air 20 °C/40 % rel. humidity
— These operating conditions are not permissible, because the maximum supply air temperature of 60 °C is exceeded.
Table C6: Heat output, RoofVent
®
LKW
Note
The output for coverage of the fabric heat losses (Q
TG
) allows for the ventilation heat requirement
(Q
V
) and the energy recovery output (Q
ER
) under the respective air conditions. It is calculated as
follows: Q
TG
= Q + Q
ER
– Q
V
RoofVent
®
LKW
Technical data
Содержание RoofVent CON-9
Страница 2: ......
Страница 4: ...2...
Страница 6: ...4...
Страница 8: ...6...
Страница 12: ...10 RoofVent LHW Use...
Страница 40: ...38 RoofVent LKW Use...
Страница 68: ...66 RoofVent twin heat Use...
Страница 94: ...92 RoofVent twin cool Use...
Страница 122: ...120 RoofVent twin pump Use...
Страница 150: ...148...
Страница 154: ...152 RoofVent condens Use...
Страница 180: ...210 RoofVent LH Construction and operation...
Страница 208: ...238 RoofVent LK Use...
Страница 256: ...286...
Страница 268: ...298...
Страница 274: ...304...
Страница 279: ......