Operating phases
The pellet boiler has the following operating phases:
Standby, pre-purge, ignition phase, flame stabilisation, modulating operation, burnout, burner
OFF
Info texts
The most important information on the BioLyt can be obtained via the Info key. Press the Info
key (= left menu key) and use the Arrow keys to scroll up and down.
Actual boiler
temperature
Boiler temperature
setpoint
Hours of operation
Arrow down key
Arrow up key
Software version
display module
Flue gas temperature
Current boiler output
Pellet consumption
Software version auto-
matic burner control
Boiler model
Manual operation
Press the
Manual operation/Chimney-sweep
key for longer than 5 sec. to start the manual
operating mode.
Setpoint settings for manual
operating mode
Press the + or - key; display changes
to temperature setpoint adjustment
mode. Use the + or - key to modify
the setpoint.
The different operating phases
are shown here.
Pressing the
Cancel
key or the
Manual operation/Chimney-sweep
key will end this func-
tion.
Important
: Adjust the mixer by hand. Scalding hazard due to high hot water temperature!
Actual boiler Temperature
back
Boiler temperature setpoint
back
Flue gas temperature
back
Current boiler output
back
Hours of operation
back
Pellet consumption
back
Software version display
module
back
Software version automatic
burner control
back
Boiler model
Pellet boiler 100
back
Manual operation
Boiler temperature
(Operating phases)
Cancel
Manual operation
Temperature setpoint
back
50
4 204 827 / 02