4. Fan wheel / fan box
The fan unit is checked and cleaned by the Hoval customer service as part of every maintenance visit.
- Turn the BioLyt off using the On/Off key on the InfoDisplay (Fig. 110) and wait until the display is clear.
- Open the combustion chamber door and fold up the complete control panel (Fig. 111).
- Unplug the fan connector (Fig. 112)
- Unscrew the four wing nuts on the fan cover and remove the complete fan unit (Fig. 113)
- Remove the fly ash with the vacuum cleaner.
- Lift the front of the fan box and pull it out (Fig. 114)
- Clean the top side of the reheat surface with the cleaning brush (Fig. 115)
- Clean the fan wheel with the spatula (Fig. 116)
Reassembly:
Follow the previous instructions in reverse order to reassemble the fan unit:
- Inset the fan box.
- Install the fan unit. Important: Tighten the wing nuts diagonally to ensure that the fan cover is mounted
tightly.
- Reconnect the fan connector.
- Lift the control panel securing arm (Fig. 117) and fold down the control panel.
Fig.112
Unplug the fan
connector
Fig.110
Switch off the BioLyt
Fig.113
Unscrew the fan unit
Fig.114
Pull out the fan box
Fig.115
Clean the reheat surfaces
Fig.116
Clean the fan wheel
Fig.117
Release securing arm