3.5.3 Pellet feed
Pellet feed - Burnout
The system first sends a request to convey pellets from the storage
room into the storage container. Combustion is stopped. The transport
of pellets into the burner pot is stopped, the forced draught fan con-
tinues to run until the remaining pellets are burnt and/or the burner
pot has cooled down sufficiently (Fig. 12).
Pellet feed during normal operation
The pellet feed is in operation. Pellets are fed from the storage room
into the storage container. The burner is locked out (Fig. 13).
3.5.4 Solid fuel operation / Storage tank operation
If the BioLyt pellet boiler operates in combination with a solid fuel
boiler or a storage tank, the changeover between the pellet and the
solid fuel/storage tank operating modes is done automatically by the
TopTronic
®
T controller, which is integrated into the control panel.
3. Operation
Fig. 12
Fig. 13
Pellet feed
Burnout
Pellet feed
in operation
Burner locked
14
4 204 827 / 02