3..1.4 Set suction head changeover
If your BioLyt is equipped with a fully automatic pellet feed, this menu
item allows you to select which suction head to use in the pellet stor-
age room. Four different settings are available:
- automatic mode:
Suction from all 3 suction heads,
automatic changeover.
- only suction head 1: Suction using suction head 1 only, no changeover
- only suction head 2: Suction using suction head 2 only, no changeover
- only suction head 3: Suction using suction head 3 only, no changeover
Note: If “Pellet feed, 2-suction-head operation” is selected in the ser-
vice level, “Suction using suction head 3 only” will not be displayed.
The display illumination is turned on again for 45 sec. when one of
the 6 keys is pressed (Fig. 82).
Press the
Menu
key (Fig. 83.)
Confirm the selected menu item “User level” with the
Select
key
(Fig. 84).
Select the sub-item “Suction head changeover” with the
Arrow
keys
(Fig. 85).
Confirm the selected menu item “Suction head changeover” with the
Select
key (Fig. 86).
5s
RESET
5s
RESET
5s
RESET
5s
RESET
5s
RESET
3. Operation
Fig. 82
Fig. 84
Fig. 85
Fig. 83
Fig. 86
(Operating phases)
Boiler temperature
Lighting ON
(Operating phases)
Boiler temperature
Service level
Operating level
select
back
select
back
Time
Feed operating mode
Feed time profile
Suction head changeover
select
back
Time
Feed operating mode
Feed time profile
Suction head changeover
3
4 204 827 / 02