HTTP
W
EB
GUI
–
W
EB
B
ROWSER
C
ONFIGURATION
I
NTERFACE
4985LAN Large Matrix Display 4985 - V08.00
30 / 84
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
Time Client Status
SYNCHRONIZATION
Indicates the synchronization status of the internal time output. This value describes
whether the connected components/devices can use the time information of Module
8029NTC for their own synchronization.
ON:
The time information put out by the module can be used by connected
components/devices for their own synchronization.
OFF:
The time information put out by the module
cannot
be used by connected
components/devices for their own synchronization.
ACCURACY
The
ACCURACY
field (accuracy of Network Time Client) can include the possible
values LOW - MEDIUM - HIGH. The meaning of those values is explained in
Chapter
Accuracy & NTP Basic Principles
By default the accuracy must be at least HIGH so that the module
supplies time information for synchronization.
This value can be set by the user if required.
Announcements
LEAP SECOND
announcement for inserting a leap second
Inactive:
No announcement exists
Active:
There is an announcement. A leap second is inserted on the next hour.
STD
DST
Announcement for adjustment for daylight saving time / standard time
Inactive:
No announcement exists
Active:
There is an announcement. An adjustment for daylight saving time /
standard time is made on the next hour.
NTP System Info (with NTP activated)
SYSTEM PEER
Indicates the currently used NTP Time Server for the synchronisation.
STABILITY
Indicates the current NTP stability value of Module 8029NTC in ppm.
STRATUM
Indicates the current NTP stratum value of Module 8029NTC in the value range of
1-16.
By default the stratum value of the Module 8029NTC is always one lower
than the stratum of the SYSTEM PEER.
The Module 8029NTC can only be synchronized on a SYSTEM PEER that
it is at least
STRATUM 14 or better.
LAMBDA
Indicates the current calculated NTP-LAMBDA value of Module 8029NTC in
milliseconds.