F
UNCTIONS
4985LAN Large Matrix Display 4985 - V08.00
11 / 84
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
Closing the housing
a. Push the front panel in the front guiding rails of the housing (coated side of front panel
outside)
b. Insert the fixing brackets of the side panel in the appropriate guiding rails of the housing
at the top and bottom (ATTENTION: DO NO JAM)
c. When snapping the side panel into the housing pay attention to the fact that the front
panel and the rear panel are placed in the appropriate guiding rails of the side panel
d. When snapping in, the pressure point of the spring locks (1) must be overridden
Pay attention to a secure hold when closing the large display.
1.3.2 Wall Mounting and Cable Entry
The large display is mounted at the wall by fixing apertures (a) in the rear panel.