Setpoint Profiler
Video Recorder – User Manual
203
How to hold a profiler
Table 5-14 Profiler Hold Procedure
Step
Action
Result/Notes
1
Perform steps 1 and 2 from Start procedure
(Table 5-13).
Profile menu is displayed.
2
Press Decrement button to move cursor to
Hold. Press Enter.
The profiler is held at its present value and the
segment’s events are frozen. Elapsed time
continues. Run time stops. Events are held at
their current states.
ATTENTION
A profile can also be put on HOLD by pressing the F2 button, but only if that profile’s HOLD parameter was
configured as SY1 F2. See Section 5.4.
How to reset a profiler
Table 5-15 Profiler Reset Procedure
Step
Action
Result/Notes
1
Place profiler in Hold.
See Profiler Hold procedure inTable 5-14.
1
Perform steps 1 and 2 from Start procedure
(Table 5-13).
Profile menu is displayed.
2
Press Decrement button to move cursor to
Reset. Press Enter.
Profiler is reset to segment #1. All profiler timers
are reset. All events go OFF. Profiler output
goes to starting value of segment #1.
ATTENTION
A profile can also be RESET by pressing the F3 button, but only if that profile’s RESET/RUN parameter was
configured as SY1 F3. See Section 5.4.
Содержание VRX180
Страница 1: ...Issue 3 03 03 US1I 6228 Video Recorder VRX180 User Manual ...
Страница 2: ...Issue 3 03 03 US1I 6228 ...
Страница 6: ...iv Video Recorder User Manual ...
Страница 48: ...Installation Video Recorder User Manual 34 ...
Страница 222: ...Setpoint Profiler Video Recorder User Manual 208 ...
Страница 234: ...Online Operations Using Primary Displays Video Recorder User Manual 220 ...
Страница 278: ...Appendix A Video Recorder User Manual 264 ...
Страница 290: ...Safety Video Recorder User Manual 276 ...