Français
: voir la page 21 •
Español
: vea la página 41
13 69-2091EFS—07
Outdoor sensor (optional)
6
Mount thermostat & outdoor sensor
M28490
3/16" holes for drywall
7/32" holes for plaster
Wall anchor
Detach wallplate
Mounting screw
Wallplate
M28483
M28491
M28492
Mount the sensor on
a vertical exterior wall,
at least 6 inches below
any overhang. Choose a
location protected from
direct sunlight.
Place sensor securely
in bracket, facing
away from wall.
Press and release
To check location before mounting:
Restore
thermostat Home screen, then hold the sensor
where you intend to install it and press the
CONNECT
button. If sensor is working properly,
thermostat will switch to display outdoor
temperature and humidity.