Setup function
Settings & options (factory default in bold)
36
Zone name
52
Thermostat
1 Basement
16 Exercise Room
30 Library
44 Porch
2 Bathroom
17 Family Room
31 Living Room
45 Rec Room
3 Bathroom 1
18 Fireplace
32 Lower Level
46 Sewing Room
4 Bathroom 2
19 Foyer
33 Master Bath
47 Spa
5 Bathroom 3
20 Game Room
34 Master Bed
48 Storage Room
6 Bedroom
21 Garage
35 Media Room
49 Studio
7 Bedroom 1
22 Great Room
36 Music Room
50 Sun Room
8 Bedroom 2
23 Guest Room
37 Nursery
51 Theater
9 Bedroom 3
24 Gym
38 Office
52 Thermostat
10 Bedroom 4
25 Kid's Room
39 Office 1
53 Upper Level
11 Boat House
26 Kitchen
40 Office 2
54 Utility Room
12 Bonus Room
27 Kitchen 1
41 Pantry
55 Walk In Closet
13 Computer Room
28 Kitchen 2
42 Play Room
56 Wine Cellar
14 Den
29 Laundry Room
43 Pool Room
57 Workshop
15 Dining Room
39
Wireless setup
0
Disconnect thermostat from wireless system
1
Thermostat is connected to wireless system
90
RESET
0
No reset
1
Reset installer options & program schedule to factory default settings
Special functions
Comfort/Economy —
Setup Function
26
(Not available when Setup Function
17
is set to
0
):
If you choose Comfort, auxiliary heat will respond quickly to meet the temperature setpoint. If you
choose Economy, the system will wait longer. Auxiliary heat will be activated only if the setpoint is
not reached within a reasonable time.
Heat Pump Control — Fossil Fuel Backup
(Setup Function
18
):
Note: If temperature is not reached in a reasonable time, set the upstage to furnace timer
(function 21). After the designated time, the compressor will turn off and the system will switch to
back up heat.
Heat Pump Control — Electric Backup
(Setup Functions
24
-
25
):
Installer setup tables
40
55
M28705
COMPRESSOR LOCKOUT
AUXILIARY LOCKOUT
COMPRESSOR AND FAN ONLY
COMPRESSOR AND FAN OPERATE
ELECTRIC BACKUP HEAT AND FAN ONLY
OUTDOOR TEMP
.
IF THE COMPRESSOR CANNOT REACH OR MAINTAIN TEMPERATURE SETTING,
BOTH THE COMPRESSOR AND ELECTRIC BACKUP HEAT WILL OPERATE.
1
1
M28706
IF ROOM TEMPERATURE DROPS (EXCEEDS DROOP SETTING AT FUNCTION 20), COMPRESSOR IS DEACTIVATED. FOSSIL FUEL
BACKUP HEAT IS ACTIVATED AFTER 3 MINUTE DELAY.
1
FOR GEOTHERMAL HEAT PUMPS, THE BALANCE POINT CAN BE DISABLED AT SETUP FUNCTION 24.
**
OPTION 0: NO DROOP CONTROL
40
BALANCE
POINT **
COMPRESSOR AND
FAN ONLY
FOSSIL FUEL
BACKUP HEAT ONLY
OUTDOOR TEMP
.
OPTION 1: DROOP CONTROL
OUTDOOR TEMP
.
40
BALANCE
POINT **
COMPRESSOR AND
FAN OPERATE
FOSSIL FUEL
BACKUP HEAT ONLY
1
OPTION 2: DROOP CONTROL WITH AUX HEAT LOCKOUT
COMPRESSOR AND FAN OPERATE
OUTDOOR TEMP
.
40
55
BALANCE
POINT **
AUXILIARY
LOCKOUT
COMPRESSOR AND FAN ONLY
FOSSIL FUEL BACKUP HEAT ONLY
1