![Honeywell 11 kW Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/honeywell/11-kw/11-kw_owners-manual_151452010.webp)
Section 2: General Information
6
Owner’s Manual for 60 Hz Air-cooled Generators
Specifications
Generator
Engine
The specification sheet for your generator was included in the documentation provided with the unit at the time of
purchase. For additional copies, consult your local Independent Authorized Service Dealer for your specific generator
model.
Model
8 kW
11 kW
16 kW
17 kW
20 kW
22 kW
Rated Voltage
240
Rated Maximum Load
Current (Amps) at Rated
Voltage*
33.3
45.8
66.6
70.8
83.3
91.7
Main Circuit Breaker
35 Amp
50 Amp
65 Amp
65 Amp
90 Amp
100 Amp
Phase
1
Rated AC Frequency
60 Hz
Battery Requirement
Group 26R, 12 Volts and 540 CCA Minimum
)
Enclosure
Aluminum
Aluminum
Aluminum
Steel
Aluminum/Steel
Aluminum
Weight (lbs/kilos)
350/159 358/162
419/190
455/206
458/208 (Aluminum)
484/220 (Steel)
475/215
Normal Operating Range
This unit is tested in accordance to UL 2200 standards with an operating temperature of -20 ºF (-29 ºC) to 122 ºF (50
ºC). For areas where temperatures fall below 32 ºF (0 ºC) a cold weather kit is recommended. When operated above
77 ºF (25 ºC) there may be a decrease in engine power. (Please reference the engine specifications section.
These generators are rated in accordance with UL 2200, Safety Standard for Stationary Engine Generator Assemblies, and CSA-C22.2 No. 100-04
Standard for Motors and Generators.
* Natural Gas ratings will depend on specific fuel joules/Btu content. Typical derates are between 10-20% off the LP gas rating.
** Circuits to be moved must be protected by same size breaker. For example, a 15 amp circuit in the main panel must be a 15 amp circuit in the
transfer switch.
Model
8 kW
11 kW
16/17 kW
20/22 kW
Type of Engine
GH-410
GTH-530
GT-990
GT-999
Number of Cylinders
1
2
2
2
Displacement
410 cc
530 cc
992 cc
999 cc
Cylinder Block
Aluminum w/ cast iron sleeve
Recommended Spark Plug
Spark Plug Gap
0.508 mm (0.020 in)
0.76 mm (0.030 in)
1.02 mm (0.040 in)
1.02 mm (0.040 in)
Valve Clearance
0.05 - 0.1 mm
(0.002 - 0.004 in)
0.05 - 0.1 mm
(0.002 - 0.004 in)
0.05 - 0.1 mm
(0.002 - 0.004 in)
0.05 - 0.1 mm
(0.002 - 0.004 in)
Starter
12 VDC
Oil Capacity Including Filter
Approx. 1.5 qt/ 1.4 l
Approx. 1.7 qt/ 1.6 l
Approx. 1.9 qt/ 1.8 l
Approx. 1.9 qt/ 1.8 l
Recommended Oil Filter
Recommended Air Filter
Engine power is subject to and limited by such factors as fuel Btu/joules, ambient temperature and altitude. Engine power decreases about 3.5 percent
for each 1000 feet (304.8 meters) above sea level, and also will decrease about 1 percent for each 6 ºC (10 ºF) above 15 ºC (60 ºF) ambient temperature.
Содержание 11 kW