NOTE: The limits must be installed as shown. If installed incorrectly the unit will not function properly.
Close garage door by hand. Determine the position of the close limit switch (1) (long wire) by aligning the centre of
trolley and the centre of the limit switch. The limit switches are actuated by a magnet in the inner trolley.
Insert bottom tab (5) of limit switch (1) into bottom lip of rail (7). Insert top tab (4) under top lip of rail (6). Lift limit
assembly against top lip of rail and tighten screw (8) to secure close limit switch.
Open garage door by hand to the full open position. Pull red handle to disengage door past inner trolley. Determine
the position of the open limit switch (3) (short wire) by aligning the centre of the trolley and the centre of the limit
switch.
Insert bottom tab (5) of limit switch (1) into bottom lip of rail (7). Insert top tab (4) under top lip of rail (6). Lift limit
assembly against top lip of rail and tighten screw (8) to secure open limit switch.
Insert wires for limit switch (9) into top channel of rail (10). Secure wires with wire clip. the wires must be secured so
they do not interfere with the travel of the trolley. Re-engage trolley then activate transmitter, the opener will operate
and reconnect to the door automatically.
Run opener 2 full travel cycles. If the door reverses in mid travel go to setting the force section. Adjust limit switch-
es as necessary to fully open and close the door without reversing.
18
ATTACH LIMIT SWITCHES
2
1
2
1
The force is programmed to operate most doors,
however, if limits are not able to be set, or the door
reverses during normal operation follow this proce-
dure:
Locate the program button (1) on the left side panel
of unit (2). Push the program button twice to enter
unit into auto-force adjustment mode.
The green LED will flash slowly.
Activate unit with remote and run the unit to the
open limit. Activate unit again to run the unit to the
closed limit.
The door must travel through a complete cycle up
and down in order for the force to be set properly.
If the unit stops before it reaches the open or close
limit repeat the process.
The green LED will stop flashing when the force
has been learned