Rev. 1.10
12
November 04, 2019
Rev. 1.10
13
November 04, 2019
HT45F5Q-3
Battery Charger Flash MCU
HT45F5Q-3
Battery Charger Flash MCU
Absolute Maximum Ratings
Supply Voltage
...........................................................................................................V
SS
-0.3V to 6.0V
Input Voltage
.....................................................................................................V
SS
-0.3V to V
DD
+0.3V
Storage Temperature
.....................................................................................................
-50°C to 125°C
Operating Temperature
.................................................................................................
-40°C to 105°C
I
OH
Total
......................................................................................................................................
-80mA
I
OL
Total
.......................................................................................................................................
80mA
Total Power Dissipation
...........................................................................................................
500mW
Note: These are stress ratings only. Stresses exceeding the range specified under “Absolute
Maximum Ratings” may cause substantial damage to the device. Functional operation of the
device at other conditions beyond those listed in the specification is not implied and prolonged
exposure to extreme conditions may affect device reliability.
D.C. Characteristics
For data in the following tables, note that factors such as oscillator type, operating voltage, operating
frequency, pin load conditions, temperature and program instruction type, etc., can all exert an
influence on the measured values.
Operating Voltage Characteristics
Ta=-40°C~105°C
Symbol
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
V
DD
Operating Voltage – HIRC
f
SYS
=f
HIRC
=8MHz
2.2
—
5.5
V
Operating Voltage – LIRC
f
SYS
=f
LIRC
=32kHz
2.2
—
5.5
V
Operating Current Characteristics
Ta=-40°C~105°C
Symbol
Operating Mode
Test Conditions
Min.
Typ.
Max.
Unit
V
DD
Conditions
I
DD
SLOW Mode – LIRC
5V
f
SYS
=32kHz, OPA0/1 enable
—
0.6
1.2
mA
FAST Mode – HIRC
5V
f
SYS
=8MHz, OPA0/1 enable
—
2.2
3.6
mA
Note: When using the characteristic table data, the following notes should be taken into consideration:
1. Any digital inputs are setup in a non-floating condition.
2. All measurements are taken under conditions of no load and with all peripherals in an off state.
3. There are no DC current paths.
4. All Operating Current values are measured using a continuous NOP instruction program loop.
Standby Current Characteristics
Ta=25
°C, unless otherwise specified
Symbol
Standby Mode
Test Conditions
Min. Typ. Max.
Max.
@85°C
Max.
@105°C Unit
V
DD
Conditions
I
STB
SLEEP Mode
5V WDT on
—
0.6
1.2
1.2
1.2
mA
IDLE0 Mode – LIRC
5V f
SUB
on
—
0.6
1.2
1.2
1.2
mA
IDLE1 Mode – HIRC
5V f
SUB
on, f
SYS
=8MHz
—
1.2
2.0
2.0
2.0
mA
Note: When using the characteristic table data, the following notes should be taken into consideration:
1. Any digital inputs are setup in a non-floating condition.
2. All measurements are taken under conditions of no load and with all peripherals in an off state.
3. There are no DC current paths.
4. All Standby Current values are taken after a HALT instruction execution thus stopping all instruction execution.