Rev. 1.00
156
September 11, 2018
Rev. 1.00
157
September 11, 2018
HT45F4050
A/D NFC Flash MCU
HT45F4050
A/D NFC Flash MCU
• UCR1 Register
The UCR1 register together with the UCR2 register are the two UART control registers that are used
to set the various options for the UART function, such as overall on/off control, parity control, data
transfer bit length etc. Further explanation on each of the bits is given below:
Bit
7
6
5
4
3
2
1
0
Name
UARTEN
BNO
PREN
PRT
STOPS
TXBRK
RX8
TX8
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
W
POR
0
0
0
0
0
0
x
0
"x": unknown
Bit 7
UARTEN
: UART function enable control
0: Disable UART. TX and RX pins are in a floating state
1: Enable UART. TX and RX pins function as UART pins
The UARTEN bit is the UART enable bit. When this bit is equal to "0", the UART will
be disabled and the RX pin as well as the TX pin will be set in a floating state. When
the bit is equal to "1", the UART will be enabled and the TX and RX pins will function
as defined by the TXEN and RXEN enable control bits.
When the UART is disabled, it will empty the buffer so any character remaining in
the buffer will be discarded. In addition, the value of the baud rate counter will be
reset. If the UART is disabled, all error and status flags will be reset. Also the TXEN,
RXEN, TXBRK, RXIF, OERR, FERR, PERR and NF bits will be cleared, while the
TIDLE, TXIF and RIDLE bits will be set. Other control bits in UCR1, UCR2 and
BRG registers will remain unaffected. If the UART is active and the UARTEN bit is
cleared, all pending transmissions and receptions will be terminated and the module
will be reset as defined above. When the UART is re-enabled, it will restart in the
same configuration.
Bit 6
BNO
: Number of data transfer bits selection
0: 8-bit data transfer
1: 9-bit data transfer
This bit is used to select the data length format, which can have a choice of either
8-bit or 9-bit format. When this bit is equal to "1", a 9-bit data length format will be
selected. If the bit is equal to "0", then an 8-bit data length format will be selected. If
9-bit data length format is selected, then bits RX8 and TX8 will be used to store the
9th bit of the received and transmitted data respectively.
Bit 5
PREN
: Parity function enable control
0: Parity function is disabled
1: Parity function is enabled
This is the parity enable bit. When this bit is equal to "1", the parity function will be
enabled. If the bit is equal to "0", then the parity function will be disabled.
Bit 4
PRT
: Parity type selection bit
0: Even parity for parity generator
1: Odd parity for parity generator
This bit is the parity type selection bit. When this bit is equal to "1", odd parity type
will be selected. If the bit is equal to "0", then even parity type will be selected.
Bit 3
STOPS
: Number of Stop bits selection
0: One stop bit format is used
1: Two stop bits format is used
This bit determines if one or two stop bits are to be used. When this bit is equal to "1",
two stop bits are used. If this bit is equal to "0", then only one stop bit is used.