75
Appendix 2- Troubleshooting
PROBLEM
CAUSE AND SOLUTION
Vacuum System
Vacuum loss or failure.
•
Vacuum blower is not engaged. Activate power
system vacuum blower.
•
Vacuum system on power supply has a problem
and is not operating properly. Troubleshoot and
repair vacuum system on power supply.
•
Vacuum RPM not high enough. Adjust RPM
higher.
•
A vacuum hose is worn through or damaged.
Replace worn or damaged vacuum hose.
•
Vacuum hose plugged with debris. Hit hose with
dead blow hammer to breakup debris. Replace
hose if necessary.
• Worn or improperly adjusted shroud wear brush.
Adjust or replace wear brush.
• Broken vacuum hose or fitting. Inspect hose &
fittings and replace any parts damaged.
• Seal damaged or missing in fitting. Replace
missing or damaged seal.
• Vacuum line plugged with debris. Remove
clogged hose, flush to remove blockage or
replace with new hose if necessary