6 Mounting/Installation
Operating manual mzr-2542 / mzr
-
2942
Last update: January 2016
Technical data subject to change without prior notice!
41
Technical data
General specification
Supply voltage
U
B
24
V DC
Max. continuous current
I
dauer
0.5
*
A
Max. peak current
I
max
1
A
Speed controller type
PID-Controller
Velocity range
100 … 6000 *
rpm
Analogue input
An_in
10-bit AD-Converter
Potentiometer 10 k
Voltage signal 0 … 10
V
Current signal 4 … 20
mA
Direction input
L / R
low 0 … 0.5 / high 4 … U
B
(low level: right direction)
V
Enable input
Enable
low 0 … 0.5 / high 4 … U
B
(low level: Enable)
V
Error output
Error
Open collector, max. 20 mA,
high 4 … U
B
: no error
Speed impulse output
Enc_out
Open collector, max. 20 mA, encoder
signal Channel A
Measurements (L x W x H)
approx. 68 x 57 x 24
mm
Weight
35
g
* Values for the respective pump type are limited by controller software
Table 28
Technical data
Pin
Description
Motor pin
Description
K1
24 VDC
M1
Motor +
K2
GND
M2
+ 5 V
K3
5 V_out
M3
Channel A
K4
An_in
M4
Channel B
K5 SGND
M5
GND
K6
Error
M6
Motor –
K7 Enc_out
K8
L / R
K9 Enable
Table 29
Pin configuration terminal screw
Motor pin configuration 6 pole connector
0 ... 10 V
4 ... 20 mA
Poti
P1
P10
Table 30
Jumper configuration for analogue input definition
Display LED
Description
green
Power supply connected with the controller, no error
red blinking
Motor in current limit or pump blocked
green-red blinking
Speed deviation to big, pump blocked or encoder error
Table 31
LED for operating status display
1
2
6
5