6 Mounting/Installation
Operating manual mzr-2542 / mzr
-
2942
Last update: January 2016
Technical data subject to change without prior notice!
37
Startup of the micro annular gear pump
external voltage
24 VDC / 2 A
S
D
pump
adapter board
+
-
figure 24
Connection between board S-KD and micro annular gear pump mzr-2942
Warning
At the initial operation with the motor control of S KD you notice the enclosed
technical description!
!
On delivery of the motor controller S-KD with adapter board and integrated
potentiometer 50 k
only the power supply has to be attached!
1.
Connect the motorcable with the adapter board of the controller S-KD.
2.
Connect the potentiometer of 50 k
with the controller (see figure 25).
Standard modus (forwards movement of the pump:
Connection of the external potentiometer between 0 V (GND) and 3,9 V only
positive input signal.
5
7
8
9
50 kOhm
figure 25
connection of the potentiometer (standard modus forward)
Inversion modus (backwards movement of the pump used for cleaning):
Connection of the external potentiometer between –3,9 V and 0 V (GND) only
negative input signal.