2 Safety instructions
Operating manual mzr-11507
Last update: August 2016
Technical data subject to change without prior notice!.
7
2.3
Safety-conscious work
The safety instructions listed in this operating manual, the applicable national
regulations for accident prevents and all internal working, operating and safety
regulations of the operator must be complied with.
2.4
Safety instructions for the operator
The surface temperature of the motor under full load may exceed 60°C. If
needed, this surface should be protected on site against contact in order to
avoid skin burns.
The drive should be protected against dust, water vapor condensation,
humidity, splash water, aggressive gases and liquids. Please provide for
adequate air ventilation and thus cooling of the motor.
The micro annular gear pump mzr-11507 must not be used in areas exposed to
explosion risks or in the proximity of inflammable gases and vapors.
Possible leaks of dangerous liquids (for example from the shaft sealing) should
be guided away in a way not to represent any danger for the personnel and the
environment. The pump should be regularly checked for possible leakage. All
legal requirements in this matter should be followed.
The existing protections against contact for the moving parts of the pump (such
as for example the coupling) must not be removed during operation.
Take care that all risks resulting from the electric energy are excluded. (For
details please refer to the instructions provided by the authorities in charge or
your power supplier.)
Warning
Please insure, that the totality of the liquid supply accessories such as tubes,
hoses, filters etc. are free from dust or dirt particles. Impurities such as metal,
plastic or glass particles may impair or damage the pump leading to its failure.
Warning
Please, operate the pump with a filter featuring 10 µm or smaller pores. It will
protect the pump.
2.5
Safety instructions for maintenance, check and assembly of the pump
As a rule all maintenance work on the device should be performed when the
device is at a standstill. The shutdown
procedure described in this manual must
be followed. Pumps delivering liquids hazardous to health must be
decontaminated. Immediately after the work had been completed all safety
equipment and protection measures should be applied.
Before starting the operation, please take into notice the instructions listed in
the chapter 6.