Mobile Foam Unit
Version 50-150
22 of 36
7.9
Jetting operation with (filled) water tank
Set the ball valve lever at the rear into tank position
Turn on the ignition (3)
Push the START button (4)
If possible, let the engine warm up (ca. two minutes)
Push the WATER (6) or FOAM (7) button
7.10
Jetting operation without water tank
Set the ball valve lever at the rear into external position
Bring the floating filter to water and connect it with the
suction intake (9) of the MFU
Turn on the ignition (3)
Push the START button (4)
If possible, let the engine warm up (ca. two minutes)
Push the WATER (6) or FOAM (7) button
8
Cleaning the filter and flushing
Thorough cleaning of the entire system
after every use
is crucial for smooth operation,
reliability and optimum lifespan of the MFU. Remove any dirt or chemical residues with clear
water; do not use any solvents. Clean the grating of the floating filter from foreign objects.
If foam was jetted or seawater pumped, the system must be thoroughly rinsed and cleaned
afterwards. When using suction hoses for external water supply, pay attention to cleanliness
and perfect fit of the couplings. Dirt and cracks at the seals lead to the intake of air and thus
to reduced suction power.
ATTENTION
After use of seawater:
Salt crystals of dried seawater damage the surface of
affected machine parts and hoses. Rinse all parts of MFU
and vehicle, especially the extension hoses thoroughly with
clean tap water.
Содержание MFU 50-150
Страница 1: ...USER MANUAL MFU 50 150 Mobile foam unit ...