Mobile Foam Unit
Version 50-150
15 of 36
6
Installation and initial start-up
For maximum efficiency, we strongly recommend the combination of the MFU with a water
tank of greatest possible volume. This allows further the connection of the back-flow line
(bypass) with the tank. Any excess pump capacity not jetted from the gun is thereby directed
back to the tank. This extends the durability of the water supply significantly, if the gun is set
to reduced flow.
6.1
Mounting
ATTENTION
Please also note the information sheet, which is enclosed in the crate at delivery.
Put cardboard or wood between frame and lifting forks to avoid
paint damage. Raise the forks to the same height as the frame of
the MFU and move the machine carefully.
Vibrations can loosen the attachment points of rails and MFU
over time. Check the tightness of all mounting screws periodically.
We recommend the use of silicon grease on the gaskets of
the couplings to avoid leaks and facilitate opening
Connect the water tank via a hose with
C-couplings at both ends. Avoid leaks
to prevent water loss and reduced
performance due to air bubbles.
Connect the bypass line via the
supplied extension hose to the tank.
Use a wrench size 36.
Four sliding nuts are located at the bottom corners of the frame.
Matching mounting rails are screwed to the wooden pallet for safe
shipping. Remove the left, right and front cover of the machine to
get access to these fastening screws. Loosen the screws by one or
two turns. The MFU is moveable now; push it carefully onto the
forks of a pallet truck or fork lifter. Remove the rails from the pallet
and screw-fasten them at the unit's place of installation. Please pay
special attention to stability and exact spacing between the rails.
Size
36
Hook
wrench
Содержание MFU 50-150